Electrical Safety Testers
Hipot, withstanding voltage and insulation test sets for production lines and labs that check products and components for electrical safety.
Products
-
Enquire about Metrel MI 3309 BT
Metrel MI 3309 BT DeltaGT Portable Appliance Tester
Handheld PAT tester: 200 mA PE continuity, insulation at 250 / 500 V, substitute, touch and differential leakage, apparent power, portable RCD trip time, clamp current and polarity; Bluetooth, RS232, USB.
-
Enquire about Hioki 3153
Hioki 3153 Automatic Insulation/Withstanding HiTester
Automatic insulation and AC/DC withstand voltage tester: 0.2 to 5.00 kV AC/DC withstanding, 50 to 1200 V DC insulation, 32 programmable test files and an optional multipoint scanner.
-
Enquire about Rishabh HVT 5kV AC 50mA
Rishabh HVT 5kV AC 50mA High Voltage Tester, 5 kV AC, 50 mA
Manual high voltage (hipot) tester with 0 to 5 kV AC output and settable trip current up to 50 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about CIE CIE-5050A 3kV
CIE CIE-5050A 3kV AC High Voltage Breakdown Test Set 0-3kV
Portable AC hipot set for withstand and breakdown tests, continuously variable 0-3 kV, 50 mA, with analog kV and mA meters, 25 / 50 mA trip, breakdown memory and zero-start interlock. IS 1248:1983.
-
Enquire about Kyoritsu KEW 6205
Kyoritsu KEW 6205 Portable Appliance Tester (PAT), Battery Operated
Battery-operated portable appliance tester with PASS / FAIL results, a colour status backlight, 10 mA and 30 mA RCD tests, 999-result memory and printer output. Complies with AS / NZS 3760.
-
Enquire about Metrel MI 3311
Metrel MI 3311 GammaGT Portable Appliance Tester
Battery-powered handheld PAT tester for class I and class II appliances: 200 mA PE continuity, insulation at 250 / 500 V, substitute leakage, voltage and polarity test; RS232, USB and optional Bluetooth.
-
Enquire about Hioki 3174
Hioki 3174 AC Automatic Insulation/Withstanding HiTester
Withstand voltage and insulation tester for continuous testing: up to 5.00 kV AC withstanding and 500/1000 V DC insulation, PWM-generated test voltage, 8 stored settings per mode.
-
Enquire about Rishabh HVT 5kV AC 100mA
Rishabh HVT 5kV AC 100mA High Voltage Tester, 5 kV AC, 100 mA
Manual high voltage (hipot) tester with 0 to 5 kV AC output and settable trip current up to 100 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about CIE CIE-5050A 5kV
CIE CIE-5050A 5kV AC High Voltage Breakdown Test Set 0-5kV
Portable AC hipot set for withstand and breakdown tests, continuously variable 0-5 kV, 50 mA, with analog kV and mA meters, 25 / 50 mA trip, breakdown memory and zero-start interlock. IS 1248:1983.
-
Enquire about Metrel MI 3325
Metrel MI 3325 MultiServicerXD Machine and Switchboard Safety Tester
Rugged machine, switchboard and appliance safety tester to IEC/EN 60204-1 and 61439-1: 5.1 kV AC hipot, 4-wire continuity up to 25 A, insulation, loop / line impedance, RCD, leakage and discharge time.
-
Enquire about Hioki BT5525
Hioki BT5525 Battery Insulation Tester
Insulation tester for battery production lines, with a BDD function that detects tiny short circuits caused by contamination and stable insulation testing in noisy environments.
-
Enquire about Rishabh HVT 5kV DC 50mA
Rishabh HVT 5kV DC 50mA High Voltage Tester, 5 kV DC, 50 mA
Manual high voltage (hipot) tester with 0 to 5 kV DC output and settable trip current up to 50 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about Metrel MI 3340
Metrel MI 3340 AlphaEE XA Electrical Equipment Safety Tester
Touch-screen appliance and equipment tester to EN 50678 / EN 50699: continuity, insulation at 50 ... 500 V, substitute, differential, touch and PE leakage, power, PRCD, RCD and EV cable (IC-CPD) tests; Li-ion, Bluetooth.
-
Enquire about Hioki ST4030A
Hioki ST4030A Impulse Winding Tester
Impulse winding tester that finds layer shorts in motor and coil windings by comparing response waveforms: 200 MHz sampling, 12-bit resolution, LC/RC quantification, 10 μH to 100 mH.
-
Enquire about Rishabh HVT 5kV DC 100mA
Rishabh HVT 5kV DC 100mA High Voltage Tester, 5 kV DC, 100 mA
Manual high voltage (hipot) tester with 0 to 5 kV DC output and settable trip current up to 100 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about Metrel MI 3365
Metrel MI 3365 OmegaEE XD Electrical Equipment Safety Tester
OmegaEE XD appliance and equipment safety tester: 200 mA continuity, insulation, substitute, differential, touch and floating-input leakage, power, PRCD, RCD and EV cable tests, fuse test; touch screen, auto sequences.
-
Enquire about Hioki ST4200-50
Hioki ST4200-50 Partial Discharge Detector
Partial discharge detector for motor windings with AC and surge dual-mode detection, a high-frequency CT for noise resistance, 200 MS/s sampling and SW2001 multiplexer support.
-
Enquire about Rishabh HVT 10kV AC 50mA
Rishabh HVT 10kV AC 50mA High Voltage Tester, 10 kV AC, 50 mA
Manual high voltage (hipot) tester with 0 to 10 kV AC output and settable trip current up to 50 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about Metrel MI 3365 25A
Metrel MI 3365 25A OmegaEE XD 25A Electrical Equipment Safety Tester
OmegaEE XD 25A: equipment and machine safety tester with 200 mA, 10 A and 25 A protective-earth continuity, insulation, leakage currents, power, PRCD, RCD and EV cable tests; touch screen, auto sequences.
-
Enquire about Hioki ST5520
Hioki ST5520 Insulation Tester
Production-line insulation tester: test voltage set from 25 V to 1000 V in 1 V steps, results in as fast as 50 ms, quick discharge and contact check; test leads sold separately. Built-in external I/O output.
-
Enquire about Rishabh HVT 10kV AC 100mA
Rishabh HVT 10kV AC 100mA High Voltage Tester, 10 kV AC, 100 mA
Manual high voltage (hipot) tester with 0 to 10 kV AC output and settable trip current up to 100 mA, digital timer to 999 s, zero start interlock and earth open protection.
-
Enquire about Metrel MI 3365 F
Metrel MI 3365 F OmegaEE XD F Electrical Equipment Safety Tester with Flash Test
OmegaEE XD F: equipment safety tester adding 1.5 kV / 3 kV flash (high-voltage) testing to 25 A continuity, insulation, leakage, power, PRCD, RCD and EV cable tests; touch screen, auto sequences.
-
Enquire about Hioki ST5520-01
Hioki ST5520-01 Insulation Tester with BCD Output
Production-line insulation tester: test voltage set from 25 V to 1000 V in 1 V steps, results in as fast as 50 ms, quick discharge and contact check; test leads sold separately. Built-in BCD output.
-
Enquire about Metrel MI 3365 M
Metrel MI 3365 M OmegaEE XD M Medical and Electrical Equipment Safety Tester
OmegaEE XD M: equipment safety tester for medical devices (IEC/EN 62353, IEC 60601 patient and applied-part leakage) plus 25 A continuity, insulation, leakage, power, PRCD, RCD and EV tests.