Signal Conditioners
Transducers and signal conditioners that convert, isolate and scale electrical signals for meters, PLCs and SCADA.
Products
-
Enquire about Innova
Innova AC / DC Current Transducer
Innova current transducer for DIN rail or panel mounting: AC or DC current up to 100 A in, 4-20 mA, 0-5 V or 0-10 V out, 0.5% accuracy, 24 V DC supply. For PLCs, motor control and energy monitoring.
-
Enquire about Kusam Meco HC-6610
Kusam Meco HC-6610 Multifunction Power Transducer
Multifunction power transducer measuring over 90 parameters to 0.15%, with 4 isolated analog or pulse outputs, Modbus RTU or DNP3 over RS-485 + RS-232, real-time clock, wide AC / DC supply.
-
Enquire about Masibus 9000C
Masibus 9000C Signal Isolator
Masibus 9000C signal isolator: input Voltage / Current, output Voltage / Current, 20 to 265V DC/AC 50-60Hz, ≤3W supply. For field interface device, isolation of field signals.
-
Enquire about Minilec D1 IST1
Minilec D1 IST1 Loop Powered DC Signal Isolator
Minilec D1 IST1 loop powered DC signal isolator with 4-20mA DC output. Typical uses: instrumentation panels, measurement & control panels, control desk.
-
Enquire about Meco CMT
Meco CMT AC Current Transducer
DIN-rail AC current transducer: 1 A / 5 A direct or CT input to isolated 4 – 20 mA, 0 – 10 V and other DC outputs, ±0.5% of span, IEC 60688.
-
Enquire about Multispan CTR-632
Multispan CTR-632 Current Transducer
DIN-rail current transducer that converts a CT signal to a fixed analog output, single or dual output, with 3-way isolation between input, output and supply. 100-270 V AC/DC or 24 V DC supply.
-
Enquire about Unison UNI SCANNER CARD 1 - 8CH
Unison UNI SCANNER CARD 1 - 8CH Scanner Card (Analog Multiplexer), 8 Channel
Analog multiplexer card that connects one of 8 0-10 V DC channels to a single PLC analog input, the channel being picked by a 3-bit binary code; for reading many current signals with one input.
-
Enquire about Veritek VIPS 96
Veritek VIPS 96 AC/DC Voltage Transducer
DIN-rail voltage transducer, AC up to 500 V or DC up to 1000 V in, 0 – 10 V or 4 – 20 mA type outputs, class 1, 2 kV isolation.
-
Enquire about Kusam Meco TAT
Kusam Meco TAT Thermocouple Alarm Setter Transmitter with Display
Thermocouple transmitter with LED display and 2 alarm set points: K, E, J, T, R, S or B input to an isolated DC output (mA or V), 27 mm DIN rail housing.
-
Enquire about Masibus 9000E
Masibus 9000E Signal Isolator
Masibus 9000E signal isolator: input Curr / ent, output Current. For isolation of process field signals, signal isolation in VFD panels.
-
Enquire about Minilec D1 PTC3 / D1 PTV3
Minilec D1 PTC3 / D1 PTV3 Power Line Transducer
Minilec D1 PTC3 / D1 PTV3 power line transducer with 4 - 20 mA DC output.
-
Enquire about Meco CMT-TRMS
Meco CMT-TRMS AC Current Transducer, TRMS
DIN-rail TRMS AC current transducer: 1 A / 5 A direct or CT input to isolated 4 – 20 mA, 0 – 10 V and other DC outputs, ±0.5% of span.
-
Enquire about Multispan MI-431
Multispan MI-431 Slim Signal Isolator
Slim DIN-rail signal isolator (12.5 mm single output, 17.5 mm dual output) for mA and V signals, with built-in sensor supply and 3-way isolation between input, output and supply.
-
Enquire about Unison UNI SCANNER CARD 1 - 16CH
Unison UNI SCANNER CARD 1 - 16CH Scanner Card (Analog Multiplexer), 16 Channel
Analog multiplexer card that connects one of 16 0-10 V DC channels to a single PLC analog input, the channel being picked by a 4-bit binary code; for reading many current signals with one input.
-
Enquire about Veritek VIPS 97
Veritek VIPS 97 AC Current Transducer
DIN-rail AC current transducer, 0 – 1 A, 0 – 5 A or 0 – 30 A in, 0 – 10 V or 4 – 20 mA type outputs, class 1, 2 kV isolation.
-
Enquire about Kusam Meco TDA
Kusam Meco TDA AC Current Transducer, 1-phase, average to RMS
Isolated 1-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about Masibus 9000Ex-1/Ex-2
Masibus 9000Ex-1/Ex-2 Signal Isolator
Masibus 9000Ex-1/Ex-2 signal isolator: input Curr / ent, output Current. For safety barrier for analog current signals, isolation of process field signals.
-
Enquire about Minilec D2 PTC1
Minilec D2 PTC1 Current Transducer
Minilec D2 PTC1 current transducer. Typical uses: speed control feedback application, metering & relay panels for substations.
-
Enquire about Meco DTI
Meco DTI DC Isolation Transducer / DC-DC Converter
DIN-rail DC isolation transducer: mA or V DC input to an optically isolated, ripple-free 4 – 20 mA or 0 – 10 V output, ±0.5% of span.
-
Enquire about Multispan MI-532P
Multispan MI-532P Signal Isolator, Temperature (RTD) Input
Slim DIN-rail isolator that converts an RTD temperature input to an isolated analog output, single or dual, with 3-way isolation. 17.5 mm wide; 100-270 V AC or 24 V DC supply.
-
Enquire about Kusam Meco TDA(C)
Kusam Meco TDA(C) AC Current Transducer, Compact
Isolated AC current transducer: 0 – 1, 0 – 5, 0 – 10 A or dual 1 / 5 A input to 4 – 20 mA, 0 – 20 mA or 0 – 10 V DC output, ≤ 400 ms, DIN rail. Class 0.2%.
-
Enquire about Masibus 9000Ex-4x
Masibus 9000Ex-4x Switching Repeater
Masibus 9000Ex-4x switching repeater.
-
Enquire about Minilec D2 PTV1
Minilec D2 PTV1 Voltage Transducer
Minilec D2 PTV1 voltage transducer. Typical uses: generator panels, motor control panels.
-
Enquire about Meco DTI-RRL
Meco DTI-RRL DC Isolation Transducer / DC-DC Converter with Power-On LED
DIN-rail DC isolation transducer with power-on LED: mA or V DC input to an optically isolated 4 – 20 mA or 0 – 10 V output, ±0.5% of span.