Hioki 3153 Automatic Insulation/Withstanding HiTester

Brand
Hioki
Model number
3153

Automatic insulation and AC/DC withstand voltage tester: 0.2 to 5.00 kV AC/DC withstanding, 50 to 1200 V DC insulation, 32 programmable test files and an optional multipoint scanner.

Price and availability on request

Request a quote

Sent with the product details: Hioki 3153 Automatic Insulation/Withstanding HiTester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Programmable insulation (50 V to 1200 V DC) and dielectric strength (AC/DC) testing
  • Program up to 32 files of test types, test points (50 steps), and measurement settings
  • Optional scanner for multipoint automatic testing
  • Uses the PWM method to generate accurate test voltages that do not depend on the supply voltage
  • Ramp timer function for increasing or decreasing the applied voltage during dielectric strength testing at user-specified times

Specifications

Specifications
FunctionsProgram up to 32 files of 50 step test settings. 10 sets each of dielectric strength and insulation test settings, hold, buzzer
Monitor functionsOutput voltage, detected current, measured resistance, Refresh rate: 2 times/s
Power supply100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max.
Dimensions and mass320 mm (12.60 in) W × 155 mm (6.10 in) H × 480 mm (18.9 in) D, 18 kg (634.9 oz)
Supplied with
ContentsH.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1
Withstanding test
Testing voltage AC/DC0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance)
Voltage settingDigital setting (0.01 kV setting resolution)
Waveform/FrequencySine wave (5% or less distortion, unloaded), 50/60 Hz selectable
Current measurement0.01 mA to 100.0 mA, Average rectified display (Digital)
Measurement range10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution)
VoltmeterDigital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display)
Decision methodWindow comparison (digital settings)
Insulation test
Rated testing voltage50 to 1,200 V DC (in 1 V steps)
Rated testing current1 mA, Short-circuit current: 200 mA or less
Measurement range/accuracy0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ)
Decision methodWindow comparison (digital settings)
Timer
Setting range0.3 to 999 s
Ramp/delayTesting voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s
Ordering
Order code3153 (Insulation, AC/DC Withstanding Voltage)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.