Hioki 3153 Automatic Insulation/Withstanding HiTester
- Brand
- Hioki
- Model number
- 3153
- Category
- Electrical Safety Testers
Automatic insulation and AC/DC withstand voltage tester: 0.2 to 5.00 kV AC/DC withstanding, 50 to 1200 V DC insulation, 32 programmable test files and an optional multipoint scanner.
Price and availability on request
Key features
- Programmable insulation (50 V to 1200 V DC) and dielectric strength (AC/DC) testing
- Program up to 32 files of test types, test points (50 steps), and measurement settings
- Optional scanner for multipoint automatic testing
- Uses the PWM method to generate accurate test voltages that do not depend on the supply voltage
- Ramp timer function for increasing or decreasing the applied voltage during dielectric strength testing at user-specified times
Specifications
| Functions | Program up to 32 files of 50 step test settings. 10 sets each of dielectric strength and insulation test settings, hold, buzzer |
|---|---|
| Monitor functions | Output voltage, detected current, measured resistance, Refresh rate: 2 times/s |
| Power supply | 100 to 120 V, 200 to 240 V AC, (50/60 Hz), 1000 VA max. |
| Dimensions and mass | 320 mm (12.60 in) W × 155 mm (6.10 in) H × 480 mm (18.9 in) D, 18 kg (634.9 oz) |
| Contents | H.V. Test Lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Spare fuse ×1 |
|---|
| Testing voltage AC/DC | 0.2 kV to 5.00 kV AC, 500 VA (max. 30 minutes), 0.2 kV to 5.00 kV DC, 50 VA (continuance) |
|---|---|
| Voltage setting | Digital setting (0.01 kV setting resolution) |
| Waveform/Frequency | Sine wave (5% or less distortion, unloaded), 50/60 Hz selectable |
| Current measurement | 0.01 mA to 100.0 mA, Average rectified display (Digital) |
| Measurement range | 10 mA (0.01 mA resolution), 100 mA (0.1 mA resolution) |
| Voltmeter | Digital: accuracy ±1.5 % f.s. (f.s.=5.00 kV) (Average rectified display) |
| Decision method | Window comparison (digital settings) |
| Rated testing voltage | 50 to 1,200 V DC (in 1 V steps) |
|---|---|
| Rated testing current | 1 mA, Short-circuit current: 200 mA or less |
| Measurement range/accuracy | 0.10 to 9999 MΩ, 4 ranges, ± 4 % rdg. (representative values for 0.5 MΩ to 1,000 MΩ) |
| Decision method | Window comparison (digital settings) |
| Setting range | 0.3 to 999 s |
|---|---|
| Ramp/delay | Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s |
| Order code | 3153 (Insulation, AC/DC Withstanding Voltage) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.