Hioki 3174 AC Automatic Insulation/Withstanding HiTester

Brand
Hioki
Model number
3174

Withstand voltage and insulation tester for continuous testing: up to 5.00 kV AC withstanding and 500/1000 V DC insulation, PWM-generated test voltage, 8 stored settings per mode.

Price and availability on request

Request a quote

Sent with the product details: Hioki 3174 AC Automatic Insulation/Withstanding HiTester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Continuous testing of insulation (500/1000 V) and withstand voltage (100 VA transformer capacity)
  • Full remote operation when used in combination with the Safety Test Data Management Software 9267
  • Save up to 8 test settings each for the withstanding and insulation testing modes
  • Precise test voltage without power voltage dependency is generated using the PWM method

Specifications

Withstanding test
Testing voltage0.2 V AC to 5.00 kV AC
Voltage settingDigital setting, Setting resolution: 0.01 kV
Waveform/FrequencySine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable
Current measurement0.01 mA to 20.0 mA, True RMS rectified (digital display)
Measurement range10 mA (0.01 mA resolution), 20 mA (0.1 mA resolution)
Voltage meterAccuracy: ±1.5 % rdg. (1000 V or more), ±15 V (less than 1000 V), True RMS rectified
Judgment functionWindow comparator method (Digital setting)
Insulation test
Testing voltage500 V DC, 1000 V DC
Unloaded voltage1 to 1.2 times rated voltage
Rated testing current1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)
Measurement range, Accuracy0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg., 1000 MΩ to 2000 MΩ: ±8 % rdg.
Judgment functionWindow comparator method (Digital setting)
Timer
Setting range0.3 to 999 s
Ramp, DelayTesting voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s
General
FunctionsSaving 8 testing conditions, hold, buzzer, contact check
Monitor functionOutput voltage, detected current, insulation resistance, Refresh rate: 2 times/s
Power supply100 to 240 V AC, (50/60 Hz), 200 VA max.
Dimensions and mass320 mm (12.60 in)W × 155 mm (6.10 in)H × 395 mm (15.55 in)D, 15 kg (529.1 oz)
Supplied with
ContentsH.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Disconnection prevention plate ×1
Ordering
Order code3174
NoteTo perform contact checks, please purchase another High Voltage Test Lead 9615 set separately.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.