CIE
186 CIE products listed. For prices and availability, send an enquiry.
Products
-
Enquire about CIE-5050A 3kV
CIE-5050A 3kV AC High Voltage Breakdown Test Set 0-3kV
Portable AC hipot set for withstand and breakdown tests, continuously variable 0-3 kV, 50 mA, with analog kV and mA meters, 25 / 50 mA trip, breakdown memory and zero-start interlock. IS 1248:1983.
-
Enquire about CIE-5050A 5kV
CIE-5050A 5kV AC High Voltage Breakdown Test Set 0-5kV
Portable AC hipot set for withstand and breakdown tests, continuously variable 0-5 kV, 50 mA, with analog kV and mA meters, 25 / 50 mA trip, breakdown memory and zero-start interlock. IS 1248:1983.
-
Enquire about CIE-DM321T
CIE-DM321T Digital Multimeter, True RMS, Manual Ranging
Manual-ranging True RMS 3½ digit multimeter for AC/DC voltage to 1000 V DC, current to 20 A, resistance to 20 MΩ and capacitance to 20 mF, with hFE, diode, continuity, backlight and holster.
-
Enquire about CIE-PSI-1
CIE-PSI-1 Phase Sequence Indicator, Rotating Disc Type
Rotating disc phase sequence indicator for three-phase supplies from 100 V to 500 V AC, 25 to 65 Hz: the disc turns to show R-Y-B order. Needs no auxiliary supply. For horizontal use; leads with crocodile clips.
-
Enquire about CIE-PSI-2
CIE-PSI-2 Phase Sequence Indicator, Panel Mounted 96 x 96 mm
Panel-mounted 96 x 96 mm phase sequence indicator with a rotating disc, for 100-500 V AC mounted vertically or 50-500 V AC horizontally, 25 to 60 Hz, rated 30 seconds at 500 V. No auxiliary supply needed.
-
Enquire about CIE-RTS-5
CIE-RTS-5 Relay Test Set, Secondary Current Injection, 400 VA
Portable secondary injection set for protection relays: continuously variable current up to 200 A for short periods (0-1 A to 0-100 A ranges), 0-230 V AC output, fixed 50 V and 110 V, digital meters and timer.
-
Enquire about CIE-RTS-5A
CIE-RTS-5A Relay Test Set, Secondary Current Injection, 1000 VA
Portable 1000 VA secondary injection set for protection relays: variable current to 100 A (200 A for 30 s), plus 0-230 V AC or 0-240 V DC variable output, digital meters, dual-range timer and NO/NC contacts.
-
Enquire about CIE-RTS-33
CIE-RTS-33 Three Phase Relay Test Set
Three phase relay test set with variable current injection in 0-1 / 5 / 10 / 25 / 50 A ranges, 110 V phase-to-phase and 63.5 V phase-to-neutral voltages, fixed 30, 110 and 220 V DC outputs and phase angle control.
-
Enquire about CIE/222M 3T 0-1 to 0-5
CIE/222M 3T 0-1 to 0-5 Earth Tester 0-1 to 0-5 Ω, Single Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, any one range 0-1 to 0-5 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-1/10
CIE/222M 3T 0-1/10 Earth Tester 0-1-10 Ω, Dual Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, dual range 0-1-10 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-1/10/100
CIE/222M 3T 0-1/10/100 Earth Tester 0-1-10-100 Ω, Triple Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, triple range 0-1-10-100 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-1/10/100/1000
CIE/222M 3T 0-1/10/100/1000 Earth Tester 0-1-10-100-1,000 Ω, Four Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, four range 0-1-10-100-1,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-1/10/100/1000/10000
CIE/222M 3T 0-1/10/100/1000/10000 Earth Tester 0-1-10-100-1,000-10,000 Ω, Five Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, five range 0-1-10-100-1,000-10,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-2/10
CIE/222M 3T 0-2/10 Earth Tester 0-2-10 Ω, Dual Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, dual range 0-2-10 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-2/10/100
CIE/222M 3T 0-2/10/100 Earth Tester 0-2-10-100 Ω, Triple Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, triple range 0-2-10-100 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-2/10/100/1000
CIE/222M 3T 0-2/10/100/1000 Earth Tester 0-2-10-100-1,000 Ω, Four Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, four range 0-2-10-100-1,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-2/10/100/1000/10000
CIE/222M 3T 0-2/10/100/1000/10000 Earth Tester 0-2-10-100-1,000-10,000 Ω, Five Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, five range 0-2-10-100-1,000-10,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-2/20/200
CIE/222M 3T 0-2/20/200 Earth Tester 0-2-20-200 Ω, Triple Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, triple range 0-2-20-200 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-3/30
CIE/222M 3T 0-3/30 Earth Tester 0-3-30 Ω, Dual Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, dual range 0-3-30 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-3/30/300
CIE/222M 3T 0-3/30/300 Earth Tester 0-3-30-300 Ω, Triple Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, triple range 0-3-30-300 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-10 to 0-100
CIE/222M 3T 0-10 to 0-100 Earth Tester 0-10 to 0-100 Ω, Single Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, any one range 0-10 to 0-100 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-10/100
CIE/222M 3T 0-10/100 Earth Tester 0-10-100 Ω, Dual Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, dual range 0-10-100 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-10/100/1000
CIE/222M 3T 0-10/100/1000 Earth Tester 0-10-100-1,000 Ω, Triple Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, triple range 0-10-100-1,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.
-
Enquire about CIE/222M 3T 0-10/100/1000/10000
CIE/222M 3T 0-10/100/1000/10000 Earth Tester 0-10-100-1,000-10,000 Ω, Four Range, 3 Terminal, Hand Driven
CIE/222M hand-cranked 3-terminal earth tester for earth resistance, four range 0-10-100-1,000-10,000 Ω, in a cast aluminium body. Accuracy ±5% to IS 9223:1979.