Test & Measuring Instruments
Portable and bench instruments for electricians, maintenance teams, test labs and quality departments: from multimeters and clamp meters to insulation, earth, power quality and environmental testers.
All products in Test & Measuring Instruments
-
Enquire about Hioki FT6380-50
Hioki FT6380-50 Clamp On Earth Tester
Clamp-on tester that measures earthing resistance on multi-grounded systems without auxiliary earth rods or disconnecting the earth wire, and also measures AC leakage and load current.
-
Enquire about Hioki IR5050
Hioki IR5050 High Voltage Insulation Tester
5 kV insulation resistance tester for cables, transformers and motors, measuring up to 10 TΩ with automatic PI, DAR and DD diagnostics.
-
Enquire about Innova
Innova AC / DC Current Transducer
Innova current transducer for DIN rail or panel mounting: AC or DC current up to 100 A in, 4-20 mA, 0-5 V or 0-10 V out, 0.5% accuracy, 24 V DC supply. For PLCs, motor control and energy monitoring.
-
Enquire about Kusam Meco
Kusam Meco Single / Three Phase FRP Earth Discharge Rod, 11 kV to 400 kV
Highly insulated FRP telescopic earth / discharge rods for 11 kV to 400 kV systems, single phase (one rod) or three phase (three rods), with copper earthing cable and grounding clamp; for systems with limited fault levels.
-
Enquire about HTC Instruments
HTC Instruments Smart SMD Tester
Tweezer-type SMD tester for capacitance (3 nF – 30 mF), resistance (300 Ω – 30 MΩ), diode and continuity. 3000 counts, auto and manual ranging, auto scanning. Runs on a CR2032 cell.
-
Enquire about Lutron AA-104
Lutron AA-104 AC Current Bench Meter
Bench AC current meter with 2 mA, 20 mA, 200 mA and 5 A ranges, fused inputs and a large LCD; CAT II 600 V.
-
Enquire about Rishabh 1P RJ12 50-21(30)
Rishabh 1P RJ12 50-21(30) Single Phase RJ12 Current Transformer, 100 mA Output
Single phase square CT 50-21(30) with 100 mA secondary on an RJ12 socket and cable for Rishabh RJ12 meters: 50 A to 400 A primary, class 1 or 0.5, open-circuit protected.
-
Enquire about Fluke 1AC II
Fluke 1AC II Non-Contact Voltage Tester
Pocket non-contact voltage tester, 90 V to 1000 V AC: the tip glows red and it beeps when voltage is present.
-
Enquire about CIE CIE-5050A 3kV
CIE CIE-5050A 3kV AC High Voltage Breakdown Test Set 0-3kV
Portable AC hipot set for withstand and breakdown tests, continuously variable 0-3 kV, 50 mA, with analog kV and mA meters, 25 / 50 mA trip, breakdown memory and zero-start interlock. IS 1248:1983.
-
Enquire about Hioki 3153
Hioki 3153 Automatic Insulation/Withstanding HiTester
Automatic insulation and AC/DC withstand voltage tester: 0.2 to 5.00 kV AC/DC withstanding, 50 to 1200 V DC insulation, 32 programmable test files and an optional multipoint scanner.
-
Enquire about Meco 9A06
Meco 9A06 3½-Digit Autoranging Digital Multimeter
2000-count autoranging DMM: 1000 V DC, 750 V AC, 10 A AC/DC, 20 MΩ and temperature (K-type probe included); carrying case supplied.
-
Enquire about Kyoritsu KEW 1009
Kyoritsu KEW 1009 Digital Multimeter, 4000 Count
4000-count digital multimeter with auto and manual ranges, range hold, continuity buzzer, AC and DC current up to 10 A and auto power-off after about 30 minutes. Supplied with a holster.
-
Enquire about Waco AET 0-1
Waco AET 0-1 Analogue Earth Tester 0-1 Ω, Single Range, 4 Terminal, Hand Driven
Hand-cranked analogue 4-terminal earth tester from Waco, single range 0-1 Ω, for earth electrode resistance and soil resistivity checks on site, with no batteries to run down.
-
Enquire about Metrel CS 2890
Metrel CS 2890 Power Calibrator / Simulator
Portable calibrator and simulator for power quality analysers: precise calibration voltages and currents, plus simulation of events, flicker, harmonics to 50th, unbalance, inrush and signalling for on-site checks.
-
Enquire about Autonics DAQ-000-USB
Autonics DAQ-000-USB High Performance Display Unit (Serial / Parallel Input) DAQ-000-USB
Autonics DAQ-000-USB high performance display unit (Serial / parallel input) (DS / DA Series).
-
Enquire about Selec AHF-030
Selec AHF-030 Active Harmonic Filter AHF-030
Selec AHF-030 active harmonic filter: 21kVAr at 415V, 308V to 460V supply.
-
Enquire about MCM Instruments 110
MCM Instruments 110 Bearing (Shock Pulse) Condition Analyzer
Microprocessor-based shock pulse bearing analyser: -19 to 99 dBpv with good / reduced / bad indication, lubrication condition and damage severity readings for rolling bearings, single-point memory.
-
Enquire about Multispan APFC-308
Multispan APFC-308 Automatic Power Factor Controller, 8 Stage, 3 CT
8-stage automatic power factor controller with three-CT current sensing (primary 5 to 9999 A), auto, manual and rotation modes for capacitor banks, and an alarm output.
-
Enquire about Veritek VIPS 70
Veritek VIPS 70 Multifunction Power Meter, LED
Three-phase multifunction power meter with 4-row LED display, class 0.5S, harmonics (THD) and maximum demand; RS485 on the VIPS 70C.
-
Enquire about Minilec D1 IST1
Minilec D1 IST1 Loop Powered DC Signal Isolator
Minilec D1 IST1 loop powered DC signal isolator with 4-20mA DC output. Typical uses: instrumentation panels, measurement & control panels, control desk.
-
Enquire about SEW 275 HP
SEW 275 HP High Voltage Proximity Detector
Non-contact proximity detector for live lines from 240 V to 275 kV, with 8 voltage settings, bright LED and audible alarm, self-test and IP65 nylon case. Fits most link sticks for high-voltage work.
-
Enquire about Masibus 8040
Masibus 8040 128-Channel Data Logger / DAQ Module
Masibus 8040 128-Channel data logger / DAQ module. For data acquisition and control application, transformer monitoring and protection.
-
Enquire about Megger BM5200
Megger BM5200 5 kV Insulation Resistance Tester
Compact 5 kV insulation tester with digital and analogue arc display: test voltages from 250 V to 5000 V, readings from 100 kΩ to 1 TΩ, PI and timed tests, guard terminal and AC / DC voltmeter.
-
Enquire about Motwane DECT-2
Motwane DECT-2 Digital Clamp-on Earth Resistance Tester
Clamp-on earth resistance tester: clamp around the rod or strip and read 0.01 Ω to 1200 Ω without disconnecting the ground. Large 65 x 32 mm jaw, alarm limits and 99-reading memory.