Enquire about IRLVD-2200
IRLVD-2200 Infrared Video Thermometer, −50 to 2200 °C
Infrared video thermometer, −50 – 2200 °C, 50:1, 2.2" colour screen with 640 × 480 camera for JPEG photos and AVI video, K-type input, air temperature, humidity and dew point.
-
Enquire about KM-201P
KM-201P CT / PT Analyser
CT / PT analyser for protection and metering transformers: excitation (knee point), turns ratio 1 – 40000, polarity, ratio error and phase, secondary winding resistance and burden; frequency-conversion method, built-in printer.
-
Enquire about KM-302
KM-302 Handheld Thermal Imaging Camera, 120 × 90
Pocket thermal camera, 120 × 90 IR with 720p visible camera and image blending, −20 – 400 °C, ±2 °C or ±2%, 2.8" screen, photos and video, 8 GB memory, USB-C.
-
Enquire about KM-316-M
KM-316-M Pump-Suction Multi-Gas Detector (LEL, O2, H2S, CO)
Pump-suction 4-gas detector (LEL, O2, H2S, CO; up to 5 gases to order), 2.4" full-colour IPS screen, built-in self-priming pump, rubber-armoured waterproof case; Ex ib IIB T3 Gb, IP65.
-
Enquire about KM-840-CO
KM-840-CO Portable Single Gas Detector, Carbon Monoxide (CO)
Single-gas detector for carbon monoxide (CO): 0 – 1000 ppm; alarms 50 / 150 ppm; resolution 1 ppm, ±5% FS, two-level alarms with voice, backlit dot-matrix LCD; Ex ib IIB T3Gb, IP65.
-
Enquire about KM-840-H2S
KM-840-H2S Portable Single Gas Detector, Hydrogen Sulphide (H2S)
Single-gas detector for hydrogen sulphide (H2S): 0 – 100 ppm; alarms 10 / 35 ppm; resolution 1 ppm, ±5% FS, two-level alarms with voice, backlit dot-matrix LCD; Ex ib IIB T3Gb, IP65.
-
Enquire about KM-840-LEL
KM-840-LEL Portable Single Gas Detector, Combustible Gas (LEL)
Single-gas detector for combustible gas (LEL): 0 – 100% LEL; alarms 20 / 50% LEL; resolution 1% LEL, ±5% FS, two-level alarms with voice, backlit dot-matrix LCD; Ex ib IIB T3Gb, IP65.
-
Enquire about KM-840-O2
KM-840-O2 Portable Single Gas Detector, Oxygen (O2)
Single-gas detector for oxygen (O2): 0 – 30% vol; alarms 19.5 / 23.5% vol; resolution 0.1% vol, ±5% FS, two-level alarms with voice, backlit dot-matrix LCD; Ex ib IIB T3Gb, IP65.
-
Enquire about KM-5208LP
KM-5208LP Loop Impedance Tester
Earth fault loop impedance and prospective short-circuit current tester powered from the line under test: loop ranges 20 / 200 / 2000 Ω, 15 mA range that does not trip ELCBs, PSC to 4 kA, wiring check and voltmeter; no batteries; CAT III 300 V.
-
Enquire about KM-8300-BX
KM-8300-BX Infrared Temperature Transmitter, −50 to 300 °C
Compact threaded infrared temperature transmitter, −50 – 300 °C, 20:1, 4 – 20 mA output, 24 V DC, stainless steel body Φ18 × 128 mm; IP65.
-
Enquire about KM-8600-BX
KM-8600-BX Infrared Temperature Transmitter, −50 to 600 °C
Compact threaded infrared temperature transmitter, −50 – 600 °C, 20:1, 4 – 20 mA output, 24 V DC, stainless steel body Φ18 × 128 mm; IP65.
-
Enquire about KM-CAL-802
KM-CAL-802 Thermocouple Calibrator, Source and Measure
Thermocouple calibrator that sources and measures mV and R, S, B, E, K, J, T, N thermocouples with ±0.05% basic accuracy and reference junction compensation, °C / °F.
-
Enquire about KM-CAL-803
KM-CAL-803 RTD Calibrator, Source and Measure
RTD and resistance calibrator, source 0.1 – 4000 Ω and measure 0.1 – 5000 Ω, Pt100 / Pt200 / Pt500 / Pt1000 / Cu50, ±0.05% basic accuracy, 4-digit LCD.
-
Enquire about KM-CAL-811
KM-CAL-811 Temperature Calibrator, Source (mV, Ω, TC, RTD)
Temperature source calibrator, ±0.05%: 100 mV / 1 V, 400 Ω / 4 kΩ, R / S / K / E / J / T / N / B / A / C / D thermocouples and Pt100 – Pt1000 / Cu50 RTDs, cold junction compensation, backlit 5-digit display.
-
Enquire about KM-CAL-814
KM-CAL-814 Voltage / mA Calibrator, Source
Voltage and mA source calibrator, −1 – 11 V and 0 – 30 mA with ±0.05% accuracy, 24 V loop power, automatic step / ramp waveforms, backlit 5-digit display.
-
Enquire about KM-CAL-815
KM-CAL-815 Loop Calibrator, Source and Measure
Loop calibrator: source 0 – 30 mA (±0.05%), measure ±30 V and ±30 mA (±0.02%), 24 V loop power, 0 – 20 / 4 – 20 mA, automatic step / ramp waveforms.
-
Enquire about KM-CAL-904MK-1
KM-CAL-904MK-1 Loop Calibrator, mA and V Source
Loop calibrator sourcing 0 – 24 mA (1 kΩ load, 24 V loop) and 0 – 24 V with 0.025% basic accuracy, auto ramp and step, 0 – 100% steps, open-loop alarm.
-
Enquire about KM-CAL-905
KM-CAL-905 Multifunction Process Calibrator with Pressure
Multifunction process calibrator, ±0.02%, sources and measures V, mA, Ω, frequency, thermocouples and RTDs at the same time, 24 V loop, pressure with optional modules, dual 5-digit backlit display.
-
Enquire about KM-CAL-905A
KM-CAL-905A Multifunction Process Calibrator
Multifunction process calibrator, ±0.02%, sources and measures V, mA, Ω, frequency, thermocouples and RTDs at the same time, 24 V loop (no pressure function), dual 5-digit backlit display.
-
Enquire about KM-CAL-906
KM-CAL-906 Temperature Calibrator, Source and Measure (mV, Ω, TC, RTD)
Temperature calibrator with ±0.02% accuracy: measures and sources mV, Ω, 10 thermocouple types and Pt / Cu RTDs, dual backlit display (5 digits measure, 6 digits source).
-
Enquire about KM-CAL-907
KM-CAL-907 V / mA Process Calibrator, Source and Measure
V / mA process calibrator with ±0.02% accuracy: sources V, mA, frequency and pulses, measures V, mA and frequency, 24 V loop power, optional pressure function.
-
Enquire about KM-CCT3K
KM-CCT3K 3000 A AC Rogowski Flex Clamp Current Sensor
Rogowski coil flexible current sensor, 18-inch (45.7 cm) loop, ranges 30 A / 300 A / 3000 A AC, 45 – 500 Hz, with BNC adaptor; reads directly on the KM 4000 / KM 4002 clamp meters. CAT IV 600 V.
-
Enquire about KM-CFPL-620
KM-CFPL-620 Cable Fault Pre-Locator (TDR) for Telecom and Signal Cables
TDR cable fault pre-locator for underground telecom and signal cables: open, short, earth, cross and poor-contact faults up to 8 km, ±1% × cable length, colour LCD, USB, with insulation and loop resistance tests.
-
Enquire about KM-CO-910
KM-CO-910 Mini Carbon Monoxide Detector
Pocket carbon monoxide meter, 0 – 1000 ppm, 1 ppm resolution, 5% ± 10 ppm, electrochemical sensor (about 5 years), beeper rising from 35 ppm and continuous above 200 ppm.