Kusam Meco
57 Kusam Meco products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about HC-6610
HC-6610 Multifunction Power Transducer
Multifunction power transducer measuring over 90 parameters to 0.15%, with 4 isolated analog or pulse outputs, Modbus RTU or DNP3 over RS-485 + RS-232, real-time clock, wide AC / DC supply.
-
Enquire about TAT
TAT Thermocouple Alarm Setter Transmitter with Display
Thermocouple transmitter with LED display and 2 alarm set points: K, E, J, T, R, S or B input to an isolated DC output (mA or V), 27 mm DIN rail housing.
-
Enquire about TDA
TDA AC Current Transducer, 1-phase, average to RMS
Isolated 1-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about TDA(C)
TDA(C) AC Current Transducer, Compact
Isolated AC current transducer: 0 – 1, 0 – 5, 0 – 10 A or dual 1 / 5 A input to 4 – 20 mA, 0 – 20 mA or 0 – 10 V DC output, ≤ 400 ms, DIN rail. Class 0.2%.
-
Enquire about TDA3
TDA3 AC Current Transducer, 3-phase, average to RMS
Isolated 3-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about TDF
TDF Power Frequency Transducer
Power frequency transducer for 50 or 60 Hz systems, spans ±1 to ±10 Hz (up to 1000 Hz to order), input 85 – 300 V AC, isolated DC output.
-
Enquire about TDPF
TDPF Power Factor Transducer, bi-directional
Bi-directional power factor transducer for balanced 1φ 2W, 3φ 3W or 3φ 4W circuits, e.g. 4 – 20 mA = −0.5 (C) … 1 … +0.5 (L). Class 0.2%.
-
Enquire about TDQ2
TDQ2 Var Transducer, bi-directional
Var transducer (bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.2%.
-
Enquire about TDQH2
TDQH2 Varhour Transducer, bi-directional
Varhour transducer (bi-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.2%.
-
Enquire about TDV
TDV AC Voltage Transducer, 1-phase, average to RMS
Isolated 1-phase AC voltage transducer (average to RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about TDV3
TDV3 AC Voltage Transducer, 3-phase, average to RMS
Isolated 3-phase AC voltage transducer (average to RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.2%.
-
Enquire about TDW
TDW Watt Transducer, uni-directional
Watt transducer (uni-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.2%.
-
Enquire about TDW2
TDW2 Watt Transducer, bi-directional
Watt transducer (bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.2%.
-
Enquire about TDWH
TDWH Watthour Transducer, uni-directional
Watthour transducer (uni-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.2%.
-
Enquire about TDWH2
TDWH2 Watthour Transducer, bi-directional
Watthour transducer (bi-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.2%.
-
Enquire about TDWQ2
TDWQ2 Watt / Var Combined Transducer
Two transducers in one case: watt and var outputs (watt and var bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.2%.
-
Enquire about TDWWH
TDWWH Watt / Watthour Transducer, uni-directional
Watt / Watthour transducer (uni-directional): analog output plus open-collector energy pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits. Class 0.2%.
-
Enquire about TDWWH2
TDWWH2 Watt / Watthour Transducer, bi-directional
Watt / Watthour transducer (bi-directional): analog output plus open-collector energy pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits. Class 0.2%.
-
Enquire about TFCT
TFCT AC Current Isolated Sensor (true RMS)
Current transformer and transducer in one (true RMS conversion): cable through a 33 mm opening, 5 – 400 A primary, 4 – 20 mA 2- or 4-wire output, ±0.5% R.O.; 6 kV transient protection.
-
Enquire about TRMT
TRMT Multifunction Power Transducer with Display
Single or 3-phase multifunction transducer in a 120 mm DIN enclosure with LED display: V, A, W, VAr, PF, Hz, Wh, VArh, RS-485 Modbus RTU; replaces 10 or more single-function transducers.
-
Enquire about TSA
TSA AC Current Transducer, 1-phase, average to RMS
Isolated 1-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSA3
TSA3 AC Current Transducer, 3-phase, average to RMS
Isolated 3-phase AC current transducer (average to RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSAR
TSAR AC Current Transducer, 1-phase, true RMS
Isolated 1-phase AC current transducer (true RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSAR3
TSAR3 AC Current Transducer, 3-phase, true RMS
Isolated 3-phase AC current transducer (true RMS conversion), 0 – 1 / 5 / 10 A AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.