Metrel MI 3394 XS CE MultiTesterXS Electrical Safety Tester

Brand
Metrel
Model number
MI 3394 XS

Multifunction electrical equipment safety tester for type, in-line, end-of-line and periodic testing: 5 kV AC / 6 kV DC hipot with < 30 ms trip-out, continuity up to 25 A, insulation, leakage and power tests.

Price and availability on request

Request a quote

Sent with the product details: Metrel MI 3394 XS CE MultiTesterXS Electrical Safety Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Includes all features of the CE MultiTester XA instrument
  • XS (Extended Safety) version supports connection of safety modules for independent control of dangerous measuring circuits and / or limitation of output current
  • Supported safety modules make the instrument safer to use (up to PLe or SIL 3) and ready for integration into production lines
  • Control of measuring circuits with help of Safety sets
  • Support for CE Switch 5 kV
  • Limitation of current in HV test to safe level in combination with Safety sets
  • Perfectly suited for use in working places according to EN 50191
  • Programmable HV AC 100 V - 5100 V and HV DC 500 V - 6000 V
  • Earth continuity with 0.2 A, 4 A, 10 A, 25 A
  • Insulation resistance, protective conductor, touch and substitute leakage currents
  • Discharging time and functional (power) test

Specifications

HV test
HV AC (programmable 100 V - 5100 V, 10 V steps)0 ... 5.99 kV, ±⁠(3 % of reading); test current 0.0 ... 99.9 mA; output power 500 VA max
HV DC (programmable 500 V - 6000 V, 50 V steps)0 ... 6.99 kV, ±⁠(3 % of reading); test current 0.01 ... 9.99 mA
Trip out time (current exceeds high limit)< 30 ms
Continuity
Earth continuity 0.2 A, 4 A, 10 A, 25 A0.00 Ω ... 999 Ω; ±⁠(2 % of reading + 2 digits) up to 19.99 Ω
Insulation
Insulation resistance LN-PE / LN-Probe (50 V ... 1000 V)0.00 MΩ ... 199.9 MΩ; ±⁠(3 % of reading + 2 digits) up to 19.99 MΩ at 250 V ... 1000 V
Leakage
Protective conductor current (residual, direct, alternative)0.00 mA ... 19.99 mA; ±⁠(3 % of reading + 5 digits)
Touch current (direct / alternative)0.00 mA ... 19.99 mA
Discharging time
Discharging time / Up0.0 ... 9.9 s / 0 ... 550 V
Functional test
P, S, Q, PF, THDup to 3.70 kW / 3.70 kVA / 3.70 kvar
General
Mains supply overvoltage categoryCAT II / 300V
HV output5 kV a.c. / 6 kV d.c., double insulation
DisplayColour TFT display, 4.3 inch, 480 x 272 pixels
Dimensions (w×h×d) / weight43.5 cm × 29.2 cm × 15.5 cm / 17 kg
Supplied with
BUNDLE S 2115 Safety Test System with Current-LimitationThe Metrel Current-Limited Safety Test System is designed for high-voltage end-of-line (EOL) testing in production environments, with the test current limited to Itest ≤ 3 mA to significantly reduce operator risk. The solution combines inherent current limitation with continuous current monitoring, safety interlocking, emergency stop and external start control, ensuring controlled and deliberate test operation. When properly implemented in accordance with EN 50191 principles, this low-energy arc

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.