Metrel MI 3394 CE MultiTesterXA Electrical Safety Tester
- Brand
- Metrel
- Model number
- MI 3394
- Category
- Electrical Safety Testers
Electrical safety tester for CE testing of appliances, machines and switchboards in production: 5 kV AC / 6 kV DC hipot, continuity up to 25 A, insulation, leakage currents, discharge time and functional power test.
Price and availability on request
Key features
- High Voltage, programmed (AC/DC)
- High Voltage, burn test (optional A 1560)
- Continuity tests
- Insulation resistance measurement
- Substitute leakage current
- Differential leakage current
- Touch leakage current
- PE-leakage current
- Discharge time
- Functional test (power P/S/Q, voltage, current, cos fi, frequency, ThdU, ThdI,PF)
- Creation of structure with dedicated tests
- PASS/FAIL evaluation of test results
- Execution of all single tests
- Programmable High Voltage (AC + DC) test
- 4-wire continuity test
Specifications
| HV AC (programmable 100 V - 5100 V, 10 V steps) | 0 ... 5.99 kV, ±(3 % of reading); test current 0.0 ... 99.9 mA; output power 500 VA max |
|---|---|
| HV DC (programmable 500 V - 6000 V, 50 V steps) | 0 ... 6.99 kV, ±(3 % of reading); test current 0.01 ... 9.99 mA |
| Test currents 0.2 A, 4 A, 10 A, 25 A | 0.000 Ω ... 999 Ω; ±(2 % of reading + 2 D) up to 1.999 Ω |
|---|
| Insulation resistance Riso / Riso-S (50 V ... 1000 V) | 0.00 MΩ ... 199.9 MΩ; ±(3 % of reading + 2 digits) up to 19.99 MΩ at 250 V ... 1000 V |
|---|
| Differential / PE / touch leakage current | 0.00 mA ... 19.99 mA; ±(3 % of reading + 5 digits) |
|---|---|
| Substitute leakage current Isub / Isub-S | 0.00 mA ... 19.99 mA; open circuit voltage <50 V a.c. |
| Discharging time / residual voltage | 0.0 ... 9.9 s / 0 ... 550 V; ±(5 % of reading + 3 digits) |
|---|
| Power P / S / Q, PF, THD, U, I | up to 3.70 kVA, ±(5 % of reading); current 0 mA ... 16.00 A; voltage 0.1 V ... 264 V |
|---|
| Power supply | 110 V / 230 V AC, 50 Hz / 60 Hz |
|---|---|
| Overvoltage category | CAT II / 300 V, CAT II / 600 V (DISCH1 / DISCH2 only) |
| HV output | 5 kV a.c. / 6 kV d.c., double insulation |
| Communication | 4 x RS232, 1 x USB, 1 x Bluetooth |
| Dimensions (w×h×d) / weight | 43.5 cm x 29.2 cm x 15.5 cm / 17 kg |
| Sets on Metrel's site | MI 3394 ST (standard set, supplied), MI 3394 EU (Euro set), MI 3394 LN (Line set), MI 3394 LB (Lab set) |
|---|
| MI 3394 Standard set | MI 3394 Instrument CE MultiTesterXA; HV measurement set 5m-without conclusion (S 2073); 2x A 1076 Test cable, BLK/RED, 2.5m, 2.5mm2/0.75mm2; 1x A 1710 Test lead, Red, 1.5m, 2.5mm2; 1x A 1370 Test lead, Red, 2.5m, 0.75mm2; 1x A 1369 Test lead, Black, 2.5m, 0.75mm2; 2x Crocodile clip, Black (A 1013); 3x Crocodile clip, Red (A 1064); Test cable, Black, 2m, 0.75mm2 (A 1079); 1x A 1493 Power cable, 2m, 3x1.5mm2; RS232 communication cable (A 1017); USB cable L=1m (A 1727); Soft carrying bag Size: XXL |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.