Metrel MI 3152H EurotestXC 2.5 kV Multifunction Installation Tester

Brand
Metrel
Model number
MI 3152H

EurotestXC with insulation testing up to 2.5 kV and 19.99 GΩ, PI / DAR diagnostics, plus continuity, line / loop impedance, RCD, earth (3-wire, 2 clamps) and illuminance for TN and TT systems; colour touch screen.

Price and availability on request

Request a quote

Sent with the product details: Metrel MI 3152H EurotestXC 2.5 kV Multifunction Installation Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Insulation resistance with DC voltage from 50 V to 2500 V and PI, DAR calculation
  • Varistor test
  • Continuity of PE conductors with 200 mA DC test current with polarity change
  • Continuity of PE conductors with 7 mA test current without RCD tripping
  • Line/Loop impedance combined also in one function Z AUTO
  • Loop impedance with Trip Lock RCD function
  • TRMS voltage and frequency measurements
  • Phase sequence
  • Power and THD measurement (up to the 12th harmonic)
  • RCD testing (general and selective, type AC, A, F, MI RCD, EV RCD, PRCD, PRCD-K, PRCD-S)
  • Earth resistance (3-wire and 2-clamps method)
  • Specific earth resistance with Ro-adapter (option)
  • TRMS leakage and load currents (option)
  • Illumination (option)
  • High resolution Loop impendance (mΩ) (option)
  • EVSE AUTO SEQUENCEs and function inspections
  • Determining location of cables (option)
  • QR and/or barcode scanner support (option)
  • Predefined profile dependent
  • AUTO SEQUENCEs
  • Auto TT (U, Zln, Zs, Uc)
  • Auto TN/RCD (U, Zln, Zs, Rpe)

Specifications

Continuity
200 mA (2-wire)0.00 Ω ... 1999 Ω; ±⁠(3 % of r. + 3 digits) up to 19.99 Ω
7 mA (no RCD tripping)0.00 Ω ... 1999 Ω; ±⁠(5 % of r. + 3 digits)
Insulation resistance
Test voltages 50 / 100 / 250 / 500 / 1000 / 2500 V0.00 MΩ ... 19.99 GΩ (2500 V); ±⁠(5 % of r. + 3 digits) up to 19.99 MΩ
PI, DAR, DDFor test voltages 500 / 1000 / 2500 V
RCD
Contact voltage Uc0.00 V ... 99.9 V; (-0 %/+15 %) of r.
Trip-out time0.0 ms ... max. time; ±1 ms up to 40.0 ms, ±3 ms above
Impedance
Line (L-L, L-N) and loop (L-PE) impedance, Ipsc / Ipfc0.00 Ω ... 9.99 kΩ; ±⁠(5 % of r. + 5 digits) up to 99.9 Ω
Voltage
TRMS voltage / frequency0 ... 550 V, ±⁠(2 % of r. + 2 digits) / 0.00 Hz ... 499.9 Hz, ±⁠(0.2 % of r. + 1 digits)
Current
TRMS current with clampsA 1018: 0.0 mA ... 19.99 A; A 1391 AC/DC: 0.00 A ... 299.9 A
Earth resistance
3-wire0.00 Ω ... 9999 Ω; ±⁠(5 % of r. + 5 digits)
2 clamps0.00 Ω ... 39.9 Ω; ±⁠(10 % of r. + 10 digits) up to 19.99 Ω
Specific earth resistance (with Ro-adapter)0.0 Ωm ... 9999 kΩm
Illuminance
Type B / type C sensor (option)0.01 lux ... 19.99 klux; ±⁠(5 % of r. + 2 digits) with type B
General
Power supply9 VDC (6x1.5 V battery or accu, size AA)
CommunicationBT, USB, RS232
Size230 x 103 x 115 mm
Supplied with
MI 3152H Standard setInstrument MI 3152H EurotestXC; Plug commander, 1.5 m; 2.5 kV test lead, 2 x 1.5 m; Test lead, 3 x 1.5 m; Power supply adapter + 6 NiMH rechargeable batteries, type AA; Test probe, 4 pcs (blue, black, green, red); Crocodile clip, 4 pcs (blue, black, green, red); Earth set 20 m; RS232 - PS/2 cable; USB cable; Soft carrying bag; Soft carrying neck belt; Short instruction manual; Instruction manual

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.