Metrel MI 3102 BT EurotestXE Multifunction Installation Tester

Brand
Metrel
Model number
MI 3102 BT

Multifunction installation tester for TN, TT and IT systems: insulation to 1000 V, continuity, line / loop impedance, RCD incl. type B, earth (3-wire, 2 clamps, specific), current, ISFL, IMD and illuminance; Bluetooth.

Price and availability on request

Request a quote

Sent with the product details: Metrel MI 3102 BT EurotestXE Multifunction Installation Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Insulation resistance with DC voltage from 50 V to 1000 V
  • Continuity of PE conductors with 200 mA DC test current with polarity change
  • Continuity of PE conductors with 7 mA test current without RCD tripping
  • Line/Loop impedance
  • Loop impedance with Trip Lock RCD function
  • TRMS voltage and frequency
  • Phase sequence
  • Power and harmonics
  • RCD testing (general and selective, type AC, A, F, B, B+)
  • Earth resistance (3-wire and 2-clamps method)
  • Specific earth resistance with Ro-adapter (option)
  • TRMS leakage and load currents (option)
  • First fault leakage current (ISFL)
  • Testing of Insulation Monitoring Devices (IMDs)
  • Illumination (option)
  • Auto TT (U, Zln, Zs, Uc)
  • Auto TN/RCD (U, Zln, Zs, Rpe)
  • Auto TN (U, Zln, Zlpe, Rpe)
  • Auto IT (U, Zln, Isc, Isfl, IMD)
  • Power measurements and harmonics analysis
  • Built-in help screens for referencing on site
  • Built-in fuse tables for automatic evaluation of the line / loop impedance result

Specifications

Continuity
200 mA (2-wire)0.00 Ω ... 1999 Ω; ±⁠(3 % of r. + 3 digits) up to 19.99 Ω
7 mA (no RCD tripping)0.00 Ω ... 1999 Ω; ±⁠(5 % of r. + 5 digits)
Insulation resistance
Test voltages 50 / 100 / 250 / 500 / 1000 V0.00 MΩ ... 999 MΩ (500 / 1000 V); ±⁠(5 % of r. + 3 digits) up to 19.99 MΩ
RCD
Contact voltage Uc0.00 V ... 99.9 V; (-0 %/+15 %) of r.
Trip-out time0.0 ms ... max. time; ±1 ms up to 40.0 ms, ±3 ms above
Impedance
Line (L-L, L-N) and loop (L-PE) impedance, Ipsc / Ipfc0.00 Ω ... 9.99 kΩ; ±⁠(5 % of r. + 5 digits) up to 99.9 Ω
Voltage
TRMS voltage / frequency0 ... 550 V, ±⁠(2 % of r. + 2 digits) / 0.00 Hz ... 499.9 Hz, ±⁠(0.2 % of r. + 1 digits)
Current
TRMS current with clampsA 1018: 0.0 mA ... 19.99 A; A 1391 AC/DC: 0.00 A ... 299.9 A
Earth resistance
3-wire0.00 Ω ... 9999 Ω; ±⁠(5 % of r. + 5 digits)
2 clamps0.00 Ω ... 99.9 Ω; ±⁠(10 % of r. + 10 digits) up to 19.99 Ω
Specific earth resistance0.0 Ωm ... 99.9 kΩm
IT systems
First fault leakage current ISFL0.0 mA ... 19.9 mA; ±⁠(5 % of r. + 3 digits)
IMD testThreshold insulation resistance 5 ... 640 kΩ, indicative, up to 128 steps
Illuminance
Type B / type C sensor (option)0.01 lux ... 19.99 klux; ±⁠(5 % of r. + 2 digits) with type B
General
Power supply9 VDC (6x1.5 V battery or accu, size AA)
Overvoltage category1000 V DC CAT II; 600 V CAT III; 300 V CAT IV
CommunicationBT, USB, RS232
Weight / size1.3 kg / 230 x 103 x 115 mm
Supplied with
MI 3102 BT Standard setInstrument MI 3102 BT EurotestXE; Plug commander, 1.5 m; Test lead, 3 x 1.5 m; Earth test set, 3-wire, 20 m (test lead, 4 m; 2 x test lead, 20 m; 2 x test rod); Power supply adapter + 6 NiMH rechargeable batteries, size AA; Test probe, 3 pcs (blue, black, green); Crocodile clip, 3 pcs (blue, black, green); RS232 - PS/2 cable; USB cable; Soft carrying neck belt; Soft carrying bag; Calibration certificate; Short instruction manual; Instruction manual; PC Software EuroLink PRO

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.