Metrel MI 3102 BT EurotestXE Multifunction Installation Tester
- Brand
- Metrel
- Model number
- MI 3102 BT
- Category
- Installation Testers
Multifunction installation tester for TN, TT and IT systems: insulation to 1000 V, continuity, line / loop impedance, RCD incl. type B, earth (3-wire, 2 clamps, specific), current, ISFL, IMD and illuminance; Bluetooth.
Price and availability on request
Key features
- Insulation resistance with DC voltage from 50 V to 1000 V
- Continuity of PE conductors with 200 mA DC test current with polarity change
- Continuity of PE conductors with 7 mA test current without RCD tripping
- Line/Loop impedance
- Loop impedance with Trip Lock RCD function
- TRMS voltage and frequency
- Phase sequence
- Power and harmonics
- RCD testing (general and selective, type AC, A, F, B, B+)
- Earth resistance (3-wire and 2-clamps method)
- Specific earth resistance with Ro-adapter (option)
- TRMS leakage and load currents (option)
- First fault leakage current (ISFL)
- Testing of Insulation Monitoring Devices (IMDs)
- Illumination (option)
- Auto TT (U, Zln, Zs, Uc)
- Auto TN/RCD (U, Zln, Zs, Rpe)
- Auto TN (U, Zln, Zlpe, Rpe)
- Auto IT (U, Zln, Isc, Isfl, IMD)
- Power measurements and harmonics analysis
- Built-in help screens for referencing on site
- Built-in fuse tables for automatic evaluation of the line / loop impedance result
Specifications
| 200 mA (2-wire) | 0.00 Ω ... 1999 Ω; ±(3 % of r. + 3 digits) up to 19.99 Ω |
|---|---|
| 7 mA (no RCD tripping) | 0.00 Ω ... 1999 Ω; ±(5 % of r. + 5 digits) |
| Test voltages 50 / 100 / 250 / 500 / 1000 V | 0.00 MΩ ... 999 MΩ (500 / 1000 V); ±(5 % of r. + 3 digits) up to 19.99 MΩ |
|---|
| Contact voltage Uc | 0.00 V ... 99.9 V; (-0 %/+15 %) of r. |
|---|---|
| Trip-out time | 0.0 ms ... max. time; ±1 ms up to 40.0 ms, ±3 ms above |
| Line (L-L, L-N) and loop (L-PE) impedance, Ipsc / Ipfc | 0.00 Ω ... 9.99 kΩ; ±(5 % of r. + 5 digits) up to 99.9 Ω |
|---|
| TRMS voltage / frequency | 0 ... 550 V, ±(2 % of r. + 2 digits) / 0.00 Hz ... 499.9 Hz, ±(0.2 % of r. + 1 digits) |
|---|
| TRMS current with clamps | A 1018: 0.0 mA ... 19.99 A; A 1391 AC/DC: 0.00 A ... 299.9 A |
|---|
| 3-wire | 0.00 Ω ... 9999 Ω; ±(5 % of r. + 5 digits) |
|---|---|
| 2 clamps | 0.00 Ω ... 99.9 Ω; ±(10 % of r. + 10 digits) up to 19.99 Ω |
| Specific earth resistance | 0.0 Ωm ... 99.9 kΩm |
| First fault leakage current ISFL | 0.0 mA ... 19.9 mA; ±(5 % of r. + 3 digits) |
|---|---|
| IMD test | Threshold insulation resistance 5 ... 640 kΩ, indicative, up to 128 steps |
| Type B / type C sensor (option) | 0.01 lux ... 19.99 klux; ±(5 % of r. + 2 digits) with type B |
|---|
| Power supply | 9 VDC (6x1.5 V battery or accu, size AA) |
|---|---|
| Overvoltage category | 1000 V DC CAT II; 600 V CAT III; 300 V CAT IV |
| Communication | BT, USB, RS232 |
| Weight / size | 1.3 kg / 230 x 103 x 115 mm |
| MI 3102 BT Standard set | Instrument MI 3102 BT EurotestXE; Plug commander, 1.5 m; Test lead, 3 x 1.5 m; Earth test set, 3-wire, 20 m (test lead, 4 m; 2 x test lead, 20 m; 2 x test rod); Power supply adapter + 6 NiMH rechargeable batteries, size AA; Test probe, 3 pcs (blue, black, green); Crocodile clip, 3 pcs (blue, black, green); RS232 - PS/2 cable; USB cable; Soft carrying neck belt; Soft carrying bag; Calibration certificate; Short instruction manual; Instruction manual; PC Software EuroLink PRO |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.