Masibus 9000C Signal Isolator
- Brand
- Masibus
- Model number
- 9000C
- Category
- Signal Conditioners
Masibus 9000C signal isolator: input Voltage / Current, output Voltage / Current, 20 to 265V DC/AC 50-60Hz, ≤3W supply. For field interface device, isolation of field signals.
Price and availability on request
Key features
- Available in Aux Powered (AP) and Loop Powered (LP) options
- Slim DIN rail mount design of 12.5mm for single output and 17.5mm for dual output
- Rugged & accurate 4 wire and 2 wire Isolator
- Switch option for 0/4-20mA, 0/1-5V and 0-10V I/O selection
- Extended universal power supply range: 20V to 265V DC or AC (Aux Powered Model)
- Up to 2 outputs with short circuit protection
- Full three port isolation
- High CMRR and NMRR
- High output load driving capability
- Wide zero & span adjustment limits
- Front calibration facility via multiturn trimpot
- Lowest long term drift
- Available with EMI-EMC compliance (optional)
- HART pass through feature (optional, available in AP compatible with 2 wire transmitter)
Specifications
| Input Type | Voltage / Current |
|---|---|
| Input Range | ‘S' Version: 4-20mA ‘M' Version: 0/4 to 20mA, 0/1 to 5V, 0 to 10VDC (DIP switch selection) |
| Input Impedance Current Input Voltage Input | ≤10 Ω ≥1 MΩ |
| Temperature Coefficient | ≤100 ppm/°C |
| CMRR | >100 dB |
| NMRR | >70 dB |
| Output Type | Voltage / Current |
|---|---|
| Output Range | ‘S' Version: 4-20mA ‘M' Version: 0/4 to 20mA , 0/1 to 5V, 0 to 10VDC (DIP switch selection) |
| Response Time | ≤50ms |
| Output Loop Status LED | Green ("S" version only) |
| Low Voltage Directive 2014/35/EU | *IEC 61010-1 :2010 |
|---|---|
| *Applicable only for CE marked | 9000C SOP Aux Powered ‘S' and ‘M' Model. |
| Supply Voltage | 20 to 265V DC/AC 50-60Hz, ≤3W |
|---|
| MountingType | DIN Rail (35mm) |
|---|---|
| Terminal Block | UL, CSA standard |
| Terminal Cable Size | 2.5 mm2 |
| Enclosure Material | PA66 |
| IP Rating | IP20 |
| SOP Model (in mm) | 12.5(W) x 100.2(H) x 115.2(D) |
|---|---|
| DOP Model (in mm) | 17.5(W) x 100.2(H) x 115.2(D) |
| SOP Model | 100 gms approx |
|---|---|
| DOP Model | 130 gms approx |
| Operating Temperature | 0 to 55 °C |
|---|---|
| Relative Humidity | 30 to 95% RH (Non-Condensing) |
| Protection | Conformal Coating on PCB |
| Applications | Field interface device, Isolation of field signals, Distribution of signals, Factory automation, Translation of signals, SCADA, DCS, Impedance matching of transmitters and receiver instruments, Powering of field transmitters |
|---|---|
| Industries | Power Stations, Cement, Waste Water Treatment Plants, Sugar, Pulp & Paper, Metal, Panel Manufacturing |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.