Rishabh
125 Rishabh products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about CON V
CON V Programmable AC Voltage Transducer
Programmable true RMS AC voltage transducer, class 0.2, with single or dual isolated 0/4-20 mA or 0-10 V outputs; programmed on site via optional LCD or RS485 Modbus.
-
Enquire about CT Ducer 70x30
CT Ducer 70x30 Current Transformer with Transducer, 70 x 30 mm
CT and transducer in one 70 x 30 mm window unit: AC current 50 A to 300 A to 4-20 mA or 0-20 mA DC, TRMS or average versions, class 0.5, spring clamp terminals.
-
Enquire about CT Ducer 90x40
CT Ducer 90x40 Current Transformer with Transducer, 90 x 40 mm
CT and transducer in one 90 x 40 mm window unit: AC current 50 A to 750 A to 4-20 mA or 0-20 mA DC, TRMS or average versions, class 0.5, spring clamp terminals.
-
Enquire about CW 500
CW 500 Open Loop Hall Effect Current Transducer, ±500 A
Open loop Hall effect current transducer for ±500 A nominal (±1500 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about CW 600
CW 600 Open Loop Hall Effect Current Transducer, ±600 A
Open loop Hall effect current transducer for ±600 A nominal (±1800 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about CW 850
CW 850 Open Loop Hall Effect Current Transducer, ±850 A
Open loop Hall effect current transducer for ±850 A nominal (±2550 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about CW 1000
CW 1000 Open Loop Hall Effect Current Transducer, ±1000 A
Open loop Hall effect current transducer for ±1000 A nominal (±3000 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about Ducer E13
Ducer E13 3 Channel AC Current / Voltage Transducer
Three channel transducer: up to 3 AC current (to 10 A) or voltage (to 750 V) inputs converted to 3 isolated-from-supply DC current or voltage outputs; class 0.5, AC or DC auxiliary.
-
Enquire about LTRC-1 80/30(50)
LTRC-1 80/30(50) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-1 (80/30(50)), 60 A to 160 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-1 80/30(50) P
LTRC-1 80/30(50) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-1 (80/30(50)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-2 90/50(40)
LTRC-2 90/50(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-2 (90/50(40)), 200 A to 320 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-2 90/50(40) P
LTRC-2 90/50(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-2 (90/50(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-3 110/72(40)
LTRC-3 110/72(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-3 (110/72(40)), 400 A to 630 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-3 110/72(40) P
LTRC-3 110/72(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-3 (110/72(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-4 135/85(40)
LTRC-4 135/85(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-4 (135/85(40)), 800 A to 1250 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-4 135/85(40) P
LTRC-4 135/85(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-4 (135/85(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-5 165/115(40)
LTRC-5 165/115(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-5 (165/115(40)), 1500 A to 2000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-5 165/115(40) P
LTRC-5 165/115(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-5 (165/115(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-6 195/130(40)
LTRC-6 195/130(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-6 (195/130(40)), 2500 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-6 195/130(40) P
LTRC-6 195/130(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-6 (195/130(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-7 230/165(40)
LTRC-7 230/165(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-7 (230/165(40)), 3000 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-7 230/165(40) P
LTRC-7 230/165(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-7 (230/165(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-8 295/200(40)
LTRC-8 295/200(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-8 (295/200(40)), 4000 A to 5000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-8 295/200(40) P
LTRC-8 295/200(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-8 (295/200(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.