Rishabh
125 Rishabh products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about 1P RJ12 50-21(30)
1P RJ12 50-21(30) Single Phase RJ12 Current Transformer, 100 mA Output
Single phase square CT 50-21(30) with 100 mA secondary on an RJ12 socket and cable for Rishabh RJ12 meters: 50 A to 400 A primary, class 1 or 0.5, open-circuit protected.
-
Enquire about 1P RJ12 50-30(30)
1P RJ12 50-30(30) Single Phase RJ12 Current Transformer, 100 mA Output
Single phase square CT 50-30(30) with 100 mA secondary on an RJ12 socket and cable for Rishabh RJ12 meters: 75 A to 600 A primary, class 1 or 0.5, open-circuit protected.
-
Enquire about 1P RJ12 62-30(40)
1P RJ12 62-30(40) Single Phase RJ12 Current Transformer, 100 mA Output
Single phase square CT 62-30(40) with 100 mA secondary on an RJ12 socket and cable for Rishabh RJ12 meters: 50 A to 800 A primary, class 1 or 0.5, open-circuit protected.
-
Enquire about 1P RJ12 62-40(40)
1P RJ12 62-40(40) Single Phase RJ12 Current Transformer, 100 mA Output
Single phase square CT 62-40(40) with 100 mA secondary on an RJ12 socket and cable for Rishabh RJ12 meters: 100 A to 800 A primary, class 1 or 0.5, open-circuit protected.
-
Enquire about CBCT 38
CBCT 38 Core Balance Current Transformer
Core balance CT with 38 mm window (OD 71 mm) for earth leakage relays: 600:1 ratio, 30 mA - 30 A operating range, class 3 or 15, UL approved, sealable terminal cap.
-
Enquire about CBCT 57
CBCT 57 Core Balance Current Transformer
Core balance CT with 57 mm window (OD 97 mm) for earth leakage relays: 600:1 ratio, 30 mA - 30 A operating range, class 3 or 15, UL approved, sealable terminal cap.
-
Enquire about CBCT 70
CBCT 70 Core Balance Current Transformer
Core balance CT with 70 mm window (OD 109 mm) for earth leakage relays: 600:1 ratio, 30 mA - 30 A operating range, class 3 or 15, UL approved, sealable terminal cap.
-
Enquire about CBCT 120
CBCT 120 Core Balance Current Transformer
Core balance CT with 120 mm window (OD 153 mm) for earth leakage relays: 600:1 ratio, 30 mA - 30 A operating range, class 3 or 15, UL approved, sealable terminal cap.
-
Enquire about CBCT 210
CBCT 210 Core Balance Current Transformer
Core balance CT with 210 mm window (OD 250 mm) for earth leakage relays: 600:1 ratio, 30 mA - 30 A operating range, class 3 or 15, UL approved, sealable terminal cap.
-
Enquire about Compact Split 36-18
Compact Split 36-18 Compact Split Core Current Transformer
Compact hinged split core CT 36-18 for tool-free fitting on insulated conductors in tight panels: 50 A to 600 A range, 1 A or 5 A output with lead, class 1 or 3.
-
Enquire about Compact Split 50-18
Compact Split 50-18 Compact Split Core Current Transformer
Compact hinged split core CT 50-18 for tool-free fitting on insulated conductors in tight panels: 50 A to 600 A range, 1 A or 5 A output with lead, class 1 or 3.
-
Enquire about Compact Split 50-32
Compact Split 50-32 Compact Split Core Current Transformer
Compact hinged split core CT 50-32 for tool-free fitting on insulated conductors in tight panels: 50 A to 600 A range, 1 A or 5 A output with lead, class 1 or 3.
-
Enquire about CON CA AVG
CON CA AVG AC Current Transducer, 22.5 mm, Average
Narrow 22.5 mm AC current transducer, average (calibrated to RMS) sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON CA Dual
CON CA Dual AC Current Transducer, Dual Output
Dual output AC current transducer, average (calibrated to RMS) sensing, two isolated outputs 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON CA TRMS
CON CA TRMS AC Current Transducer, 22.5 mm, True RMS
Narrow 22.5 mm AC current transducer, true RMS sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON CV AVG
CON CV AVG AC Voltage Transducer, 22.5 mm, Average
Narrow 22.5 mm AC voltage transducer, average (calibrated to RMS) sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON CV Dual
CON CV Dual AC Voltage Transducer, Dual Output
Dual output AC voltage transducer, average (calibrated to RMS) sensing, two isolated outputs 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON CV TRMS
CON CV TRMS AC Voltage Transducer, 22.5 mm, True RMS
Narrow 22.5 mm AC voltage transducer, true RMS sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about CON Hz
CON Hz Programmable Frequency Transducer
Frequency transducer for 45-55, 48-52, 55-65 or 45-65 Hz on 57-500 V inputs, single or dual 0/4-20 mA or 0-10 V outputs, class 0.2, optional LCD and RS485.
-
Enquire about CON I
CON I Programmable AC Current Transducer
Programmable true RMS AC current transducer, class 0.2, with single or dual isolated 0/4-20 mA or 0-10 V outputs; programmed on site via optional LCD or RS485 Modbus.
-
Enquire about CON I11
CON I11 Self Powered AC Current Transducer
Self powered AC current transducer: 1 A or 5 A input to 0-1/5/10/20 mA, 4-20 mA or 0-10 V output, class 0.5, response under 200 ms; DIN rail or wall mounting.
-
Enquire about CON M
CON M Multi Transducer with Analog / Relay Outputs
Programmable 3 phase multi transducer for V, I, power, PF, frequency, energy and THD with 4 analog, 4 relay or 2 analog + 2 relay outputs, RS485 Modbus and USB; ±0.2% V / I.
-
Enquire about CON M+
CON M+ Programmable Multi-function Transducer
4-in-1 programmable multi-function transducer for 1 or 3 phase systems: up to 4 isolated analog outputs and 2 relays, class 0.2 analog, class 0.5S energy, THD to 31st, RS485 and USB.
-
Enquire about CON P
CON P Programmable Power Transducer
Programmable active, reactive and apparent power, phase angle and power factor transducer for 1 or 3 phase balanced / unbalanced systems; class 0.2, 1 or 2 outputs, LCD and RS485 options.