Rishabh
10 Rishabh products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about AIT 501
AIT 501 Smart 5 kV Digital Insulation Tester
Compact 5 kV insulation tester with 500 V, 1000 V, 2500 V and 5000 V tests up to 1 TΩ, automatic PI and DAR, AC/DC volts to 600 V, logging with USB and Go/No-Go comparator.
-
Enquire about Insu 5Dt
Insu 5Dt 5 kV Digital Insulation Tester
5 kV digital insulation tester for long cables, generators, motors and transformers: 100 V to 5 kV in 25 V steps, 50 kΩ to 2 TΩ, PI/DAR/step/ramp tests, touch screen, Bluetooth / USB.
-
Enquire about Insu 5Dx+
Insu 5Dx+ 5 kV Digital Insulation Tester
5 kV digital insulation tester for utilities and live switchyards: 100 V to 5 kV, up to 10 TΩ, 8 mA noise rejection, PI/DAR/DD/step/ramp and burn/breakdown tests, Bluetooth and USB.
-
Enquire about Insu 10
Insu 10 Analog-Digital Insulation and Continuity Tester, 1000 V
Battery analog-digital insulation and continuity tester: 50 V to 1000 V test voltages, 10 kΩ to 999 MΩ, low ohms to 99.9 Ω, voltage to 600 V AC/DC, memory and stop watch.
-
Enquire about Insu 10Dx+
Insu 10Dx+ 10 kV Digital Insulation Tester
10 kV digital insulation tester for power utilities and HV switchyards: 100 V to 10 kV, up to 20 TΩ, 8 mA noise rejection, PI/DAR/DD/step/ramp tests, Bluetooth and USB, Li-ion battery or mains.
-
Enquire about Insu 20
Insu 20 Analog-Digital Insulation and Continuity Tester, 1000 V
Battery analog-digital insulation and continuity tester: 50 V to 1000 V test voltages, 10 kΩ to 2 GΩ, low ohms to 99.9 Ω, voltage to 600 V AC/DC, memory and stop watch.
-
Enquire about Insu 5000 A
Insu 5000 A Analog High Voltage Insulation Tester, 5 kV, Battery Operated
Analog 5 kV insulation tester for battery operation: eight test voltages 100 V to 5000 V, 10 kΩ to 1 TΩ, voltage measurement to 2000 V, guard terminal; IS 2992 / EN 61557.
-
Enquire about Insu 5000 AK
Insu 5000 AK Analog High Voltage Insulation Tester, 5 kV, Hand Crank Operated
Analog 5 kV insulation tester for hand crank generator operation: eight test voltages 100 V to 5000 V, 10 kΩ to 1 TΩ, voltage measurement to 2000 V, guard terminal; IS 2992 / EN 61557.
-
Enquire about Insu 5000 M
Insu 5000 M Analog High Voltage Insulation Tester, 5 kV, Mains Operated
Analog 5 kV insulation tester for mains operation: eight test voltages 100 V to 5000 V, 10 kΩ to 1 TΩ, voltage measurement to 2000 V, guard terminal; IS 2992 / EN 61557.
-
Enquire about Insu 5000 R
Insu 5000 R Analog High Voltage Insulation Tester, 5 kV, Mains with Rechargeable Battery
Analog 5 kV insulation tester for mains operation with rechargeable battery: eight test voltages 100 V to 5000 V, 10 kΩ to 1 TΩ, voltage measurement to 2000 V, guard terminal; IS 2992 / EN 61557.