Kusam Meco
478 Kusam Meco products listed. For prices and availability, send an enquiry.
Products
-
Enquire about KM-PS-303
KM-PS-303 DC Power Supply, 0 – 30 V / 0 – 3 A
Single-output linear bench power supply, 0 – 30 V / 0 – 3 A, constant voltage and constant current, coarse and fine knobs, LED voltage and current displays, ripple < 1.0 mV rms.
-
Enquire about KM-PS-303D-II
KM-PS-303D-II Dual Output DC Power Supply, 2 × 0 – 30 V / 0 – 3 A
Dual-output linear bench power supply, 2 × 0 – 30 V / 0 – 3 A plus a fixed 5 V / 3 A output; series, parallel or independent by switch; automatic CV / CC; four LED displays.
-
Enquire about KM-PS-305
KM-PS-305 DC Power Supply, 0 – 30 V / 0 – 5 A
Single-output linear bench power supply, 0 – 30 V / 0 – 5 A, constant voltage and constant current, coarse and fine knobs, LED voltage and current displays, ripple < 1.0 mV rms.
-
Enquire about KM-PS-305D-II
KM-PS-305D-II Dual Output DC Power Supply, 2 × 0 – 30 V / 0 – 5 A
Dual-output linear bench power supply, 2 × 0 – 30 V / 0 – 5 A plus a fixed 5 V / 3 A output; series, parallel or independent by switch; automatic CV / CC; four LED displays.
-
Enquire about KM-PS-602D-II
KM-PS-602D-II Dual Output Linear DC Power Supply, 2 × 0 – 64 V / 0 – 2 A
Dual-output linear bench power supply, 2 × 0 – 64 V / 0 – 2 A (series to 128 V, parallel to 4 A), automatic CV / CC, four LED displays.
-
Enquire about KM-PS-605D-II
KM-PS-605D-II Dual Output Linear DC Power Supply, 2 × 0 – 64 V / 0 – 5 A
Dual-output linear bench power supply, 2 × 0 – 64 V / 0 – 5 A (series to 128 V, parallel to 10 A), automatic CV / CC, four LED displays.
-
Enquire about KM-PS-3010AB
KM-PS-3010AB DC Power Supply, 0 – 30 V / 0 – 10 A with 5 V Output
Bench power supply with a 0 – 30 V / 0 – 10 A variable output and a fixed 5 V / 2 A output, coarse and fine adjustment, automatic CV / CC, short-circuit and overload protection.
-
Enquire about KM-RH-11KV
KM-RH-11KV Rescue Hook, 11 kV
Insulated rescue hook for 11 kV work areas: vinyl-dipped steel body hook with 15-inch opening on a fibre glass pole, withstand voltage 220 kV, for pulling an injured worker clear of live equipment.
-
Enquire about KM-RH-33KV
KM-RH-33KV Rescue Hook, 33 kV
Insulated rescue hook for 33 kV work areas: vinyl-dipped steel body hook with 15-inch opening on a fibre glass pole, withstand voltage 220 kV, for pulling an injured worker clear of live equipment.
-
Enquire about KM-RH-66KV
KM-RH-66KV Rescue Hook, 66 kV
Insulated rescue hook for 66 kV work areas: vinyl-dipped steel body hook with 15-inch opening on a fibre glass pole, withstand voltage 220 kV, for pulling an injured worker clear of live equipment.
-
Enquire about KM-RH-132KV
KM-RH-132KV Rescue Hook, 132 kV
Insulated rescue hook for 132 kV work areas: vinyl-dipped steel body hook with 15-inch opening on a fibre glass pole, withstand voltage 220 kV, for pulling an injured worker clear of live equipment.
-
Enquire about KM-SA9232
KM-SA9232 3.2 GHz Spectrum Analyzer
Spectrum analyser, 9 kHz – 3.2 GHz (7.5 GHz option), < −100 dBc/Hz phase noise at 10 kHz offset, < 0.8 dB amplitude accuracy, preamplifier and EMI filter standard; USB, LAN and VGA.
-
Enquire about KM-SPM-11
KM-SPM-11 Digital Solar Power Meter
Solar power meter that measures sunlight intensity up to 1999 W/m² or 634 BTU/(ft²·h), with 0.1 resolution, data hold and MAX / MIN.
-
Enquire about KM-ST-505N
KM-ST-505N Analog Multimeter
Analog multimeter with taut-band movement, 50 kΩ/V DC sensitivity, three-colour mirror scale, 10 A AC / DC, resistance to 20 MΩ and dB scale; CAT III 600 V.
-
Enquire about KM-TFC-2700L
KM-TFC-2700L Frequency Counter
2-channel frequency meter with 9-character LED display: channel A 10 Hz – 100 MHz (direct and ratio counting), channel B 100 MHz – 1 GHz, gate times 0.01 / 0.1 / 1 s, 20 mV rms sensitivity.
-
Enquire about KM-VC-5200
KM-VC-5200 Digital Vernier Caliper, 200 mm
Hardened stainless steel digital vernier caliper, 0 – 200 mm, 0.01 mm / 0.0005 inch resolution, ±0.03 mm: outer and inner diameter, depth and step; sealed against water, oil and coolant; IP54.
-
Enquire about KM-VC-5300
KM-VC-5300 Digital Vernier Caliper, 300 mm
Hardened stainless steel digital vernier caliper, 0 – 300 mm, 0.01 mm / 0.0005 inch resolution, ±0.04 mm: outer and inner diameter, depth and step; sealed against water, oil and coolant; IP54.
-
Enquire about KM 01
KM 01 Analog Insulation Resistance Tester, 100 V / 50 MΩ
Battery-powered analog insulation tester with 100 V DC test voltage and 0 – 50 MΩ logarithmic mirror scale, 600 V AC voltage range to check for live circuits, test-voltage lock and HV LED; ABS case.
-
Enquire about KM 03
KM 03 Analog Insulation Resistance Tester, 500 V / 100 MΩ
Battery-powered analog insulation tester with 500 V DC test voltage and 0 – 100 MΩ logarithmic mirror scale, 600 V AC voltage range to check for live circuits, test-voltage lock and HV LED; ABS case.
-
Enquire about KM 031
KM 031 600 A AC True RMS Clamp Meter with AmpTip and EF Detection
600 A AC true RMS clamp meter with slim 26 mm jaw and AmpTip™ for 0.01 A – 60 A, 5 ms crest capture, BeepLit™ continuity and non-contact / probe EF detection; CAT III 600 V / CAT IV 300 V.
-
Enquire about KM 035
KM 035 600 A AC/DC True RMS Clamp Meter with AmpTip and EF Detection
600 A AC / DC true RMS clamp meter with slim 26 mm jaw and AmpTip™ for 0.01 A – 60 A, 5 ms crest mode, BeepLit™ continuity and non-contact / probe EF detection; CAT III 600 V / CAT IV 300 V.
-
Enquire about KM 039F
KM 039F True RMS Fork Clamp Meter
True RMS fork clamp meter: an open 12.5 mm fork slides onto wires in tight wiring and measures up to 200 A AC; plus 600 V, motor capacitor range, DC µA, temperature and Hi / Lo NCV; CAT III 600 V / CAT IV 300 V.
-
Enquire about KM 071
KM 071 4-20 mA DC Process Clamp Meter
Process clamp meter that measures 4-20 mA loop current without breaking the circuit: 0.01 mA – ±40 mA DC, % of span readout, 5 mm jaw, backlight and spotlight.
-
Enquire about KM 072
KM 072 600 A AC True RMS Clamp Meter with VFD and AmpTip
600 A AC true RMS clamp meter with 30 mm jaw and AmpTip™ (60 A) for low currents, VFD V and Hz, low-pass filter, non-contact and probe EF detection; CAT III 600 V / CAT IV 300 V.