Kusam Meco
478 Kusam Meco products listed. For prices and availability, send an enquiry.
Products
-
Enquire about KM 805s
KM 805s 4000-Count Auto-Ranging Digital Multimeter
Auto-ranging 4000-count multimeter (average sensing) with 25 ms MAX hold, capacitance and frequency to 1 MHz; splash-proof; CAT II 1000 V, CAT III 600 V, CAT IV 300 V.
-
Enquire about KM 807s
KM 807s 4000-Count Auto-Ranging True RMS Multimeter
Auto-ranging 4000-count true RMS multimeter with backlit display, 25 ms MAX hold, capacitance, frequency to 1 MHz and type-K temperature; splash-proof; CAT II 1000 V, CAT III 600 V, CAT IV 300 V.
-
Enquire about KM 822EX
KM 822EX Intrinsically Safe True RMS Digital Multimeter
Intrinsically safe true RMS multimeter (Ex ib IIA T4 Gb / Ex ib I Mb) for Zone 1 hazardous areas and mines: 1000 V AC / DC, 10 A, 9999 counts, IP64, CAT IV 1000 V, PC interface.
-
Enquire about KM 828
KM 828 Digital Field Intensity Meter, 30 – 400 Hz
Low-frequency magnetic field meter for power cables, monitors and appliances: 0.1 – 4000 mG / 0.01 – 400 µT in 2 ranges, ±(4% rdg + 3 dgts), 30 – 400 Hz, data and peak hold.
-
Enquire about KM 829
KM 829 9999-Count True RMS Multimeter with PC Interface
AC + DC true RMS multimeter, 9999 / 6000 counts, 0.08% DC accuracy, AutoCheck LoZ, NCV and probe EF detection, dBm, IP54, CAT IV 1000 V, 12 kV transient protection, PC interface.
-
Enquire about KM 839
KM 839 20,000-Count True RMS Multimeter
ETL-listed true RMS multimeter with selectable 6000 / 20,000 counts, 0.09% DC accuracy, VFD mode, capacitance to 20 mF, temperature to 1090 °C, IP40, CAT III 1000 V / CAT IV 600 V.
-
Enquire about KM 855PR
KM 855PR Phase Sequence Meter
Contact-type phase sequence meter, 200 – 600 V AC, 50 / 60 Hz: phase sequence (R, Y, B) and open phase by LED and buzzer, large alligator clips; CAT IV 600 V.
-
Enquire about KM 857
KM 857 50,000-Count True RMS Multimeter
True RMS (AC, AC + DC) multimeter: 50,000 counts, or 500,000 counts for DC volts; 0.02% DC accuracy; AC to 20 kHz; dBm and 4-20 mA % readings; CAT III 1000 V / CAT IV 600 V.
-
Enquire about KM 859CF
KM 859CF 50,000-Count True RMS Multimeter with PC Interface
True RMS (AC, AC + DC) multimeter: 50,000 counts, or 500,000 counts for DC volts; 0.02% DC accuracy; AC to 100 kHz; T1-T2 temperature; CAT III 1000 V / CAT IV 600 V; PC interface.
-
Enquire about KM 869
KM 869 50,000-Count True RMS Multimeter with VFD and PC Interface
Top-end true RMS (AC, AC + DC) multimeter: 50,000 counts, or 500,000 counts for DC volts; 0.02% DC accuracy; VFD mode; T1-T2 temperature; dBm; IP54; CAT IV 1000 V; PC interface.
-
Enquire about KM 877
KM 877 True RMS Insulation Multimeter with Pass/Fail Compare
True RMS insulation multimeter: insulation tests at 50 – 1000 V up to 25 GΩ with pass / fail compare (12 preset values), earth continuity, VFD V and Hz, remote probe; CAT III 1000 V / CAT IV 600 V, IP40.
-
Enquire about KM 878
KM 878 True RMS Insulation Multimeter with Earth Continuity and Temperature
True RMS insulation multimeter: insulation tests at 50 – 1000 V up to 25 GΩ, earth continuity, VFD V and Hz, AC / DC mV and mA, capacitance and temperature, remote probe; CAT III 1000 V / CAT IV 600 V, IP40.
-
Enquire about KM 885PR
KM 885PR Phase Rotation Tester with Voltmeter
3-in-1 phase rotation tester, phase presence indicator and 6000-count auto-ranging AC / DC voltmeter to 600 V, large LCD, data hold; CAT III 600 V.
-
Enquire about KM 887
KM 887 True RMS Insulation Multimeter with 10 A Current
True RMS insulation multimeter: insulation tests at 50 – 1000 V up to 25 GΩ, AC / DC current to 10 A, VFD V and Hz, capacitance to 20 mF and temperature, relative zero; CAT III 1000 V / CAT IV 600 V, IP40.
-
Enquire about KM 888PMR
KM 888PMR Phase Sequence and Motor Rotation Tester
3-phase presence and rotation indicator combined with a motor rotation tester: phase presence 100 – 600 V AC, rotation and motor connection from 1 V AC, neon lamps and LEDs; CAT III 600 V.
-
Enquire about KM 891
KM 891 60,000-Count True RMS Multimeter with Data Logging
Rugged 60,000-count true RMS multimeter with data logging and PC interface: 0.025% DC accuracy, AC + DC, frequency to 60 MHz, pulse width, dBV / dBm, rechargeable lithium battery, IP65, CAT III 1000 V / CAT IV 600 V.
-
Enquire about KM 900
KM 900 Battery Quality Analyzer
Battery quality analyser for UPS and industrial batteries (lead-acid, NiCd, Li-ion, NiMH): 4-terminal impedance 4 mΩ – 4 Ω, voltage to 300 V DC, float current with CT, temperature; up to 1200 Ah; SD card logging, USB.
-
Enquire about KM 900C
KM 900C Battery Quality Analyzer with Capacity and Ripple Current
Battery quality analyser for UPS and industrial batteries (lead-acid, NiCd, Li-ion, NiMH): 4-terminal impedance 4 mΩ – 4 Ω, voltage to 300 V DC, float and ripple current with CT, capacity (% SOC, Ah, Wh), temperature; up to 6000 Ah; SD card logging, USB.
-
Enquire about KM 908MK-1
KM 908MK-1 Digital Vane Anemometer
Vane anemometer, 0 – 45 m/s (0 – 8800 ft/min), ±3%, with air temperature 0 – 45 °C, Beaufort scale, wind chill and max / min / average readings.
-
Enquire about KM 910MK-1
KM 910MK-1 CFM / CMM Air Flow Thermo-Anemometer with PC Interface
Vane thermo-anemometer, 0 – 45 m/s, air flow to 999,900 CMM / CFM, air temperature 0 – 45 °C ±1 °C, 2/3 Vmax and average flow, 500-record memory and USB.
-
Enquire about KM 917
KM 917 Concrete Moisture Meter
Non-destructive moisture meter for concrete, walls, marble and tile using HF electromagnetic sensing, 0 – 40% to about 25 mm depth, 3 material grades, upper-limit alarm.
-
Enquire about KM 918-B
KM 918-B Indoor / Outdoor Temperature and Humidity Meter
Indoor / outdoor thermometer with indoor humidity: indoor −10 – +50 °C, outdoor −50 – +90 °C, humidity 20 – 90% RH, max / min memory and comfort indication.
-
Enquire about KM 918A
KM 918A Digital Hygro-Thermometer with Clock and Alarm
Desk hygro-thermometer with clock, calendar and alarm: temperature −50 – +70 °C ±1.0 °C, humidity 10 – 99% RH, max / min memory, triple LCD.
-
Enquire about KM 918C
KM 918C Digital Thermo-Hygrometer with Clock
Indoor / outdoor thermo-hygrometer with clock, date and alarms: indoor −10 – +50 °C, outdoor −50 – +70 °C, humidity 20 – 99% RH, max / min memory.