Kusam Meco
57 Kusam Meco products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about TSCT
TSCT AC Current Isolated Sensor (RMS)
Current transformer and transducer in one (RMS conversion): cable through a 33 mm opening, 5 – 400 A primary, 4 – 20 mA 2- or 4-wire output, ±0.5% R.O.; 6 kV transient protection.
-
Enquire about TSF
TSF Power Frequency Transducer
Power frequency transducer for 50 or 60 Hz systems, spans ±1 to ±10 Hz (up to 1000 Hz to order), input 85 – 300 V AC, isolated DC output. Class 0.5%.
-
Enquire about TSPF
TSPF Power Factor Transducer, bi-directional
Bi-directional power factor transducer for balanced 1φ 2W, 3φ 3W or 3φ 4W circuits, e.g. 4 – 20 mA = −0.5 (C) … 1 … +0.5 (L). Class 0.5%.
-
Enquire about TSQ2
TSQ2 Var Transducer, bi-directional
Var transducer (bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.5%.
-
Enquire about TSQH2
TSQH2 Varhour Transducer, bi-directional
Varhour transducer (bi-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.5%.
-
Enquire about TSQQH2
TSQQH2 Var / Varhour Transducer, bi-directional
Var / Varhour transducer (bi-directional): analog output plus open-collector energy pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits. Class 0.5%.
-
Enquire about TSV
TSV AC Voltage Transducer, 1-phase, average to RMS
Isolated 1-phase AC voltage transducer (average to RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSV(C)
TSV(C) AC Voltage Transducer, Compact
Isolated AC voltage transducer: inputs such as 57.7, 100, 300, 450 or 600 V to 4 – 20 mA, 0 – 20 mA or 0 – 10 V DC output, ≤ 400 ms, DIN rail. Class 0.5%.
-
Enquire about TSV3
TSV3 AC Voltage Transducer, 3-phase, average to RMS
Isolated 3-phase AC voltage transducer (average to RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSVR
TSVR AC Voltage Transducer, 1-phase, true RMS
Isolated 1-phase AC voltage transducer (true RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSVR3
TSVR3 AC Voltage Transducer, 3-phase, true RMS
Isolated 3-phase AC voltage transducer (true RMS conversion), 0 – 150 / 300 / 600 V AC input, 4 – 20 mA, 0 – 20 mA, 0 – 10 mA or 0 – 5 / 1 – 5 / 0 – 10 V DC output. Class 0.5%.
-
Enquire about TSW
TSW Watt Transducer, uni-directional
Watt transducer (uni-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.5%.
-
Enquire about TSW2
TSW2 Watt Transducer, bi-directional
Watt transducer (bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V or 220 V and 1 A or 5 A inputs, isolated 4 – 20 mA or other DC output. Class 0.5%.
-
Enquire about TSWH
TSWH Watthour Transducer, uni-directional
Watthour transducer (uni-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.5%.
-
Enquire about TSWH2
TSWH2 Watthour Transducer, bi-directional
Watthour transducer (bi-directional) with open-collector pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.5%.
-
Enquire about TSWQ
TSWQ Watt / Var Combined Transducer
Two transducers in one case: watt and var outputs (watt uni-directional, var bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.5%.
-
Enquire about TSWQ2
TSWQ2 Watt / Var Combined Transducer
Two transducers in one case: watt and var outputs (watt and var bi-directional) for 1φ 2W, 3φ 3W or 3φ 4W circuits, 110 V / 220 V and 1 A / 5 A inputs. Class 0.5%.
-
Enquire about TSWWH
TSWWH Watt / Watthour Transducer, uni-directional
Watt / Watthour transducer (uni-directional): analog output plus open-collector energy pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits. Class 0.5%.
-
Enquire about TSWWH2
TSWWH2 Watt / Watthour Transducer, bi-directional
Watt / Watthour transducer (bi-directional): analog output plus open-collector energy pulse output, for 1φ 2W, 3φ 3W or 3φ 4W circuits. Class 0.5%.
-
Enquire about TW2D
TW2D DC Isolating Transmitter, Dual Input and Dual Output
Two-channel DC isolating transmitter: two DC inputs to two isolated DC outputs (mA or V), ±0.1%, ≤ 400 ms, DIN rail.
-
Enquire about TW2S
TW2S Current Loop Isolating Supply Transmitter, Dual Input and Dual Output
Two-channel loop supply isolator: powers two 2-wire 4 – 20 mA transmitters (24 V) and gives two isolated DC outputs, ±0.1%, DIN rail.
-
Enquire about TWD
TWD DC Isolating Transmitter
DC signal isolator: one DC input (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) to one isolated output, ±0.1%, ≤ 400 ms, 27 mm DIN rail housing.
-
Enquire about TWD2
TWD2 DC Isolating Transmitter, Dual Output
DC signal isolator: one DC input (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) to two isolated outputs, ±0.1%, ≤ 400 ms, 27 mm DIN rail housing.
-
Enquire about TWF
TWF Frequency to DC Isolating Transmitter
Frequency to DC transmitter, 50 Hz – 20 kHz user selectable, open collector, voltage pulse, relay contact or PNP input, isolated output (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V).