Masibus 9000Ex-4x Switching Repeater
- Brand
- Masibus
- Model number
- 9000Ex-4x
- Category
- Signal Conditioners
Masibus 9000Ex-4x switching repeater.
Price and availability on request
Key features
- Provides intrinsically safe digital input with galvanic isolation from output and auxiliary power
- Phase reversal allows reversing output mode
- Side DIP switches used for enable/disable Phase reversal and Line Fault Detection (LFD)
- During fault condition, output channel relay de-energizes automatically
- Advanced LFD monitoring for wire-break/ short-circuit
- Front LEDs of status/fault for ease of monitoring
- Polarised plugs and sockets for Hazardous area terminals
Specifications
| Input | Inputs conforming to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR) |
|---|---|
| Location of Switch | Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location |
| Location of Proximity Detector | Zone 0, IIC, T4-6 hazardous area, if suitably certified Div.1, Group A, hazardous location |
| Sensor Voltage | 7 to 9V dc from 1kΩ ±10% |
| Switching Points | In normal phase, Outputs closed if input > 2.1mA (< 2kΩ in input circuit) and Outputs open if input < 1.2mA (> 10kΩ in input circuit) Switching hysteresis 200µA (650Ω) nominal |
| Connection Side | Safe Area |
|---|---|
| Relay Contact rating | 250V ac, 2A, cosØ >0.7, 30V dc, 2A, resistive load, 40V dc, 1.2A, resistive load Note: reactive loads must be adequately suppressed |
| Response time | ≤ 10mS |
| Indication LED | Yellow: channel status, on when output energized Red: LFD indication, on when line fault detected |
| LFD Relay | Line fault relay is energized and channel output relay de-energized if input line-fault detected |
| Output Phase reversal | User selectable by switches on the side of the module. |
| Voltage | 20 to 35 VDC |
|---|---|
| Power Consumption | 9000Ex-41/9000Ex-41-FS/9000Ex-42/ 9000Ex-43: ≤0.9W@24V 9000Ex-44/9000Ex-45: ≤0.6W@24V |
| Power Dissipation | 9000Ex-41/9000Ex-41-FS/9000Ex-42/ 9000Ex-43: ≤0.9W@24V 9000Ex-44/9000Ex-45: ≤0.6W@24V |
| Power ON status LED | Green |
| Mounting Type | DIN Rail (35 mm) |
|---|---|
| Terminal Block | UL, CSA standard |
| Terminal Cable Size | 2.5mm2 |
| Enclosure Material | PA66 |
| IP Rating | IP20 |
| Dimension (in mm) | 17.6(W)x108(H)x114(D) mm |
| Weight | ≤150 g |
| Operating temperature | -20 to 60°C |
|---|---|
| Storage temperature | -20° to 70°C |
| Relative Humidity | 30% to 95% RH (Non-Condensing) |
| Protection | Conformal Coating on PCB |
| M odel No. | Hazardous Area Input Channel / Safe Area Output Relay / Safe Area LFD Relay |
| Certificate Report No. | KLPL/Ex/25-102, Issue No. 00 |
|---|---|
| PESO Approval No. | A/P/HQ/GA/104/5538 |
| Ex Standards Complied | IS/IEC 60079-0:2017 IS/IEC 60079-11:2023 For Details, Please refer Operational Manual |
| Applications | Protect control systems from Hazardous area faults, Connects underground sensors to surface control systems safely for mining operation, Valve position feedback and turbine pulse detection for refinery operations, Digital inputs for pumps, compressors, and reactor monitoring, Digital feedback for mixers, and process skids in API manufacturing, Skid integration with digital inputs for dosing, fuel, and burner skids |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.