Fluke 572-2 High-Temperature Infrared Thermometer

Brand
Fluke
Model number
572-2

High-temperature infrared thermometer to 900 °C with 60:1 distance-to-spot and dual laser sighting.

Price and availability on request

Request a quote

Sent with the product details: Fluke 572-2 High-Temperature Infrared Thermometer.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
  • Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
  • Features a user-selectable multi-language interface
  • Displays the temperature plus MAX, MIN, DIF, AVG temperature
  • Provides adjustable emissivity and a predefined emissivity table

Specifications

Infrared Measurements
Infrared temperature range-30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater; ≥ -10°C to < 0°C: ±2°C; < -10°C: ±3°C; ≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater; ≥ 14°F to < 32°F: ±4°F; < 14°F: ±6°F
IR repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution0.1°C; 0.1°F
Distance - Spot60:1 (calculated at 90% energy)
Minimum spot size19 mm
Laser sightingOffset dual laser, output < 1 mW
Spectral response8 μm to 14 μm
Response time (95%)< 500 ms
EmissivityDigitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range-270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)< -40°C: ±⁠(1°C + 0.2°; 1°C); ≥ -40°C: ±1% or 1°C, whichever is greater; < -40°F: ±⁠(2°F + 0.2°; 1°F); ≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple0.1°C; 0.1°F
K-type thermocouple repeatability±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarmsAudible and two-color visual
Min/Max/Avg/DifYes
Switchable celsius and fahrenheitYes
BacklightTwo levels, normal and extra bright for darker environments
Probe inputK-type thermocouple simultaneous display of probe and IR temperature
Trigger lockYes
Data storage99 points
DisplayDot matrix 98 x 96 pixels with function menus
CommunicationUSB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe)-40°C to 260°C (-40°F to 500°F)
Accuracy±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and complianceIEC 60825-1; FDA Laser Class II; IEC 61326-1; CE Complaint; CMC # 01120009
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F)
Relative humidity10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude2000 meters above mean sea level
Weight0.322 kg (0.7099 lb)
Power2 AA batteries
Battery life8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)
Supplied with
ContentsK-type thermocouple bead probe; Durable hard case; USB 2.0 computer interface cable

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 572-2

The Fluke 572-2 is designed for high-temperature industrial environments such as power utilities, metal refining, glass and cement. It measures from -30 °C to 900 °C, with a 60:1 distance-to-spot ratio and dual laser sighting for fast, accurate targeting.