Fluke 568 Ex Intrinsically Safe Infrared Thermometer
- Brand
- Fluke
- Model number
- 568 Ex
Intrinsically safe infrared and contact thermometer for Class I Div 1/2 or Zone 1/2 areas, -40 °C to 800 °C.
Price and availability on request
Key features
- Intrinsically safe infrared and contact thermometer
- Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
- Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
- Comes with a conductive case to safely carry the IR thermometer into hazardous areas
- Offers a distance-to-spot ratio of 50:1
Specifications
| Infrared temperature range | -40°C to 800°C (-40°F to 1472°F) |
|---|---|
| Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); > 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater |
| Display resolution | 0.1°C; 0.1°F |
| Infrared spectral response | 8 µm to 14 µm |
| Infrared response time | < 500 ms |
| Thermocouple type-k input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
| Thermocouple type-k input accuracy | < -40°C: ±(1°C + 0.2°/1°C); ≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F); ≥ -40°F: ±1% or 2°F, whichever is greater |
| D | S (distance to measurement spot size): 50:1 |
| Laser sighting | Single-point laser |
| Minimum spot size | 19 mm (0.75 in) |
| Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
| Data storage | 99 points |
| Hi/Low alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Display | Dot matrix with function menus |
| Backlight | Two levels, normal and extra bright for darker environments |
| Trigger lock | Yes |
| Switchable celsius and fahrenheit | Yes |
| Power | 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.) |
| Battery life | 4 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle |
| Operating temperature | 0°C to 50°C (32°F to 122°F) |
| Storage temperature | -20°C to 60°C (-40°F to 140°F) |
| Bead thermocouple type-k range | -40°C to 260°C (-40°F to 500°F) |
| Bead thermocouple type-k accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
| Contents | K-type thermocouple bead probe; Conductive IS hard carrying case; User’s manual |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 568 Ex
The Fluke 568 Ex is an intrinsically safe infrared and contact thermometer certified for Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous areas. It measures from -40 °C to 800 °C and comes with a conductive case.