Fluke 566 Infrared and Contact Thermometer
- Brand
- Fluke
- Model number
- 566
Two-in-one infrared and contact thermometer, 30:1 spot, -40 °C to 650 °C, adjustable emissivity, logging and alarms.
Price and availability on request
Key features
- Two-in-one IR and contact thermometer with a 30:1 distance-to-spot ratio
- Measures temperatures from -40°C to 650°C (40°F to 1202°F)
- Makes it easy to access advanced features with the soft-key buttons and graphical display
- Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments
- Works with most K-type thermocouples
Specifications
| Infrared temperature range | -40°C to 650°C (-40°F to 1202°F) |
|---|---|
| Infrared accuracy | < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F); > 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater |
| Display resolution | 0.1°C; 0.1°F |
| Infrared spectral response | 8 µm to 14 µm |
| Infrared response time | < 500 msec |
| Thermocouple Type-K input temperature range | -270°C to 1372°C (-454°F to 2501°F) |
| Thermocouple Type-K input accuracy, -270°C to -40°C | ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F)) |
| Thermocouple Type-K input accuracy, -40°C to 1372°C | ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater |
| D | S (distance to measurement spot size): 30:1 |
| Laser sighting | Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm |
| Minimum spot size | 19 mm (0.75 in) |
| Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
| Data storage with date/time stamp | 20 points |
| PC interface and cable | None |
| Hi/Low alarms | Audible and two-color visual |
| Min/Max/Avg/Dif | Yes |
| Display | Dot matrix 98 x 96 pixels with function menus |
| Backlight | Two levels, normal and extra bright for darker environments |
| Trigger lock | Yes |
| Switchable Celsius and Fahrenheit | Yes |
| Power | 2 AA/LR6 Batteries |
| Battery life, If used continuously | Laser and backlight on, 12 hours; laser and backlight off, 100 hours |
| Operating temperature | 0°C to 50°C (32°F to 122°F) |
| Storage temperature | -20°C to 60°C (-40°F to 140°F) |
| Bead thermocouple Type-K range | -40°C to 260°C (-40°F to 500°F) |
| Bead thermocouple Type-K accuracy | ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F), typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F) |
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 566
The Fluke 566 is a two-in-one infrared and contact thermometer with a 30:1 distance-to-spot ratio and a range of -40 °C to 650 °C. A simple three-button on-screen menu gives quick access to emissivity adjustment, data logging and alarms.