Fluke 561 HVAC Infrared and Contact Thermometer
- Brand
- Fluke
- Model number
- 561
Infrared and contact thermometer, -40 °C to 550 °C, works with type K thermocouples; pipe probe included.
Price and availability on request
Key features
- Contact and non-contact IR thermometer for measuring up close or at a distance, without a ladder
- Measures temperature from -40°C to 550° C (-40°F to 1022°F)
- Works with all standard mini-connector type K thermocouples
- Provides single-point laser sighting
- Allows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately
Specifications
| Temperature | -40 to 550°C (-40 to 1022°F) |
|---|---|
| Display resolution | 0.1°C (0.1°F) of reading |
| D | S (distance to spot size): 12:1 |
| Easy emissivity selector | Adjustable with three settings:; Low (0.3), medium (0.7). high (0.95) |
| Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] | ±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C; 32°F, ±1°C (±2°F) ±0.1°/1° |
| Response time | 500 mSec (95% of reading) |
| Repeatability | ±0.5% of reading or ±1°C (±2°F), whichever is greater |
| Spectral response | 8 µm to 14 µm |
| Laser sighting | Single point laser |
| Laser shutoff | Laser turns off above ambient temperature of 40°C (104°F) |
| Laser power | Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm |
| Relative humidity | 10% to 90% RH non-condensing, at < 30°C (86°F) |
| Power, battery life | 2 AA batteries (alkaline or NiCD) |
| Battery life | 12 hours |
| Display hold | 7 seconds |
| Backlit display | Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options |
| Warranty | 2 years |
| Operating temperature | 0°C to 50°C (32°F to 120°F) |
| Storage temperature | -20°C to 65°C (-25°F to 150°F) |
| MAX, MIN, DIF temperatures | Yes |
| Thermocouple Type K mini adapter input | Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range. |
| Thermocouple Type K fabric hook-and-loop fastener pipe probe | Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F) |
| HVAC measurement guide | Yes |
| Contents | K-Type thermocouple; Fabric hook-and-loop fastener pipe probe; Hard carrying case; 2 AA batteries; Users manual |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 561
The Fluke 561 combines an infrared thermometer for non-contact readings with contact measurement through any standard mini-connector type K thermocouple, for industrial, electrical and HVAC/R work. It measures from -40 °C to 550 °C and comes with a hook-and-loop pipe probe.