Fluke 1555 FC 10 kV Insulation Tester

Brand
Fluke
Model number
1555 FC

10 kV insulation tester for switchgear, motors, generators and cables, with Fluke Connect remote operation.

Price and availability on request

Request a quote

Sent with the product details: Fluke 1555 FC 10 kV Insulation Tester.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Quickly configure, start and stop tests on the 1555 remotely, a safe distance away from any operating, energized equipment, using Fluke Connect and a smart phone
  • Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
  • Report creation using Fluke Connect desktop saves time and makes test results easier to understand
  • Fluke Connect saves test results to the cloud for analysis and preventive maintenance

Specifications

Test voltage (DC)
250 V, Range< 250 kΩ, 250 kΩ to 5 GΩ; 5 GΩ to 50 GΩ; > 50 GΩ
250 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
500 V, Range< 500 kΩ; 500 kΩ to 10 GΩ; 10 GΩ to 100 GΩ; > 100 GΩ
500 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
1000 V, Range< 1 MΩ; 1 MΩ to 20 GΩ; 20 GΩ to 200 GΩ; > 200 GΩ
1000 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
2500 V, Range< 2.5 MΩ; 2.5 MΩ to 50 GΩ; 50 GΩ to 500 GΩ; > 500 GΩ
2500 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
5000 V, Range< 5 MΩ; 5 MΩ to 100 GΩ; 100 GΩ to 1 TΩ; > 1 TΩ
5000 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
10000 V, Range< 10 MΩ; 10 MΩ to 200 GΩ; 200 GΩ to 2 TΩ; > 2 TΩ
10000 V, Accuracy (± reading)Unspecified; 5%; 20%; Unspecified
Bar graph range0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
Insulation test voltage accuracy-0%, +10% at 1 mA load current
Induced AC mains current rejection2 mA maximum
Charging rate for capacitive load5 seconds per μF
Discharge rate for capacitive load1.5 s/μF
Leakage current measurement, Range1 nA to 2 mA
Leakage current measurement, Accuracy±⁠(5% + 2 nA)
Capacitance measurement, Range0.01 μF to 15.00 μF
Capacitance measurement, Accuracy±⁠(15% rdg + 0.03 μF)
Timer, Range0 to 99 minutes
Timer, Resolution setting1 minute
Timer, Resolution indication1 second
Live circuit warning, Warning range30 V to 660 V AC/DC, 50/60 Hz
Live circuit warning, Voltage accuracy±⁠(15% + 2 V)
Software specificationsFlukeView Forms basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
General Specifications
Display75 x 105 mm
Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA
Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
Weight3.7 kg (8.2 lb)
Temperature (operating)-20°C to 50°C (-4°F to 122°F)
Temperature (storage)-20°C to 65°C (-4°F to 149°F)
Humidity80% to 31°C decreasing linearly to 50% at 50°C
Altitude2000 m
Enclosure sealingIP40
Input overload protection1000 V AC
Safety complianceIEC 61010-1: Overvoltage category II, Pollution Degree 2.; IEC 61010-2-030: Measurement 600V CAT IV; 1000V CAT III; IEC 61557-1, IEC 61557-2

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.

About the 1555 FC

The Fluke 1555 FC tests insulation up to 10 kV on high-voltage equipment such as switchgear, motors, generators and cables. It can be operated remotely through the Fluke Connect app, with real-time trending on the phone and easy data collection.