Fluke 1550C FC 5 kV Digital Insulation Tester
- Brand
- Fluke
- Model number
- 1550C FC
- Category
- Insulation Resistance Testers
5 kV digital insulation tester with Fluke Connect remote operation and real-time trending on your phone.
Price and availability on request
Key features
- Quickly configure, start and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect and a smart phone
- Real time trending gives you easy-to-see visual cues
- Report creation using Fluke Connect desktop saves time and makes test results easier to understand
- Fluke Connect saves test results to the cloud for analysis and preventive maintenance
Specifications
| 250 V, Range | < 250 kΩ, 250 kΩ to 5 GΩ; 5 GΩ to 50 GΩ; > 50 GΩ |
|---|---|
| 250 V, Accuracy (± reading) | Unspecified; 5%; 20%; Unspecified |
| 500 V, Range | < 500 kΩ; 500 kΩ to 10 GΩ; 10 GΩ to 100 GΩ; > 100 GΩ |
| 500 V, Accuracy (± reading) | Unspecified; 5%; 20%; Unspecified |
| 1000 V, Range | < 1 MΩ; 1 MΩ to 20 GΩ; 20 GΩ to 200 GΩ; > 200 GΩ |
| 1000 V, Accuracy (± reading) | Unspecified; 5%; 20%; Unspecified |
| 2500 V, Range | < 2.5 MΩ; 2.5 MΩ to 50 GΩ; 50 GΩ to 500 GΩ; > 500 GΩ |
| 2500 V, Accuracy (± reading) | Unspecified; 5%; 20%; Unspecified |
| 5000 V, Range | < 5 MΩ; 5 MΩ to 100 GΩ; 100 GΩ to 1 TΩ; > 1 TΩ |
| 5000 V, Accuracy (± reading) | Unspecified; 5%; 20%; Unspecified |
| Bar graph range | 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) |
| Insulation test voltage accuracy | -0%, +10% at 1 mA load current |
| Induced AC mains current rejection | 2 mA maximum |
| Charging rate for capacitive load | 5 seconds per μF |
| Discharge rate for capacitive load | 1.5 s/μF |
| Leakage current measurement, Range | 1 nA to 2 mA |
| Leakage current measurement, Accuracy | ± (20% + 2 nA) |
| Capacitance measurement, Range | 0.01 μF to 15.00 μF |
| Capacitance measurement, Accuracy | ± (15% rdg + 0.03 μF) |
| Timer, Range | 0 to 99 minutes |
| Timer, Resolution setting | 1 minute |
| Timer, Resolution indication | 1 second |
| Live circuit warning, Warning range | 30 V to 660 V AC/DC, 50/60 Hz |
| Live circuit warning, Voltage accuracy | ± (15% + 2 V) |
| Software specifications | FlukeView Forms basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. |
| Display | 75 x 105 mm |
|---|---|
| Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
| Charger Input (AC) | 85 V to 250 V AC 50/60 Hz 20 VA |
| Dimensions | 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) |
| Weight | 3.7 kg (8.2 lb) |
| Temperature (operating) | -20°C to 50°C (-4°F to 122°F) |
| Temperature (storage) | -20°C to 65°C (-4°F to 149°F) |
| Humidity | 80% to 31°C decreasing linearly to 50% at 50°C |
| Altitude | 2000 m |
| Enclosure sealing | IP40 |
| Input overload protection | 1000 V AC |
| Safety compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2.; IEC 61010-2-030: Measurement 600V CAT IV; 1000V CAT III; IEC 61557-1, IEC 61557-2 |
| Contents | Test cables with alligator clips (red, black, green); Infrared adapter with interface cable; AC power cord; Soft carrying case; English manual; User's manual on CD-ROM; Quick reference card |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 1550C FC
The Fluke 1550C performs digital insulation testing up to 5 kV. Through the Fluke Connect app tests can be set up, started and stopped remotely, away from energised equipment, with a live trend graph on the phone and report creation on the desktop.