Fluke 1507 Insulation Resistance Tester
- Brand
- Fluke
- Model number
- 1507
- Category
- Insulation Resistance Testers
Advanced compact insulation tester with five test voltages, PI and DAR, compare function and remote probe.
Price and availability on request
Key features
- Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians
- Automatically calculates Polarization Index and Dielectric Absorption Ratio
- Makes repetitive tests simple and easy with a Compare (Pass/Fail) function
- Offers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V
Specifications
| Accuracy, Range | 600.0 V |
|---|---|
| Accuracy, Resolution | 0.1 V |
| Accuracy | 50 Hz to 400 Hz ± (% of Rdg + Digits); ±(2% + 3) |
| Input impedance | 3 MΩ (nominal), < 100 pF |
| Common mode rejection ratio (1 kΩ unbalanced) | > 60 dB at DC, 50 or 60 Hz |
| Overload protection | 600 V rms or DC |
| Range/Resolution | 20.00 Ω; 0.01 Ω; 200.0 Ω; 0.1 Ω; 2000 Ω; 1.0 Ω; 20.00 kΩ; 0.01 kΩ |
|---|---|
| Accuracy | ±(1.5% + 3) |
| Overload protection | 2 V rms or DC |
| Open circuit test voltage | > 4.0 V, < 8 V |
| Short circuit current | > 200.0 mA |
| Measurement range | 0.01 MΩ to 10 GΩ |
|---|---|
| Test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
| Test voltage accuracy | + 20%, - 0% |
| Short circuit current | 1 mA nominal |
| Auto discharge | Discharge time < 0.5 second for C = 1 µF or less |
| Live circuit indicator | Inhibit test if terminal voltage > 30 V prior to initialization of test |
| Maximum capacitive load | Operable with up to 1 µF load |
| Measure accuracy | 50 V; ±(3% + 5); 100 V; ±(3% + 5); 250 V; ±(1.5% + 5); 500 V; ±(1.5% + 5); 1000 V; ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ |
| Maximum voltage applied to any terminal | 600 V AC rms or DC |
|---|---|
| Storage temperature | -40°C to 60°C (-40°F to 140°F) |
| Operating temperature | -20°C to 55°C (-4°F to 131°F) |
| Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F) |
| Relative humidity | 0% to 95% @ 10°C to 30°C (50°F to 86°F); 0% to 75% @ 30°C to 40°C (86°F to 104°F); 0% to 40% @ 40°C to 55°C (104°F to 131°F) |
|---|---|
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
| Shock | 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
| Safety | Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
| Certifications | CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
| Batteries | Four AA batteries (NEDA 15A or IEC LR6) |
| Battery life, Insulation test use | Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
| Battery life, Resistance measurements | Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
| Size (H x W x L) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) |
| Weight | 550 g (1.2 lb) |
| IP rating | IP40 |
| Altitude, Operating | 2000 m CAT IV 600 V, 3000 m CAT III 600 V |
| Altitude, Non-operating (storage) | 12,000 m |
| Over-range capability | 110% of range |
| Included accessories | TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
| Contents | Remote probe; Test leads; Test probes; Alligator clips; User documentation |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.
About the 1507
The Fluke 1507 is a compact insulation tester for industrial and commercial electricians, with multiple test voltages for troubleshooting, commissioning and preventive maintenance. It calculates Polarization Index and Dielectric Absorption Ratio automatically and has a compare function for repeated tests.