Delta AX-504AN02-0S AX-5 Safety Digital Output Module, 4 Points
- Brand
- Delta
- Model number
- AX-504AN02-0S
- Category
- PLCs and Controllers
4-point PNP (sourcing) safety output module for the AX-5 safety system, with 2 test output points, 150 μs response, SIL 3 / PL e Cat. 4 and a screwless removable terminal block, in a 12 mm wide housing.
Price and availability on request
Specifications
| Model | AX-504AN02-0S |
|---|---|
| Software | DIADesigner-AX |
| Type of Terminal Block | Screwless removable terminal block (16 terminal blocks) |
| Safety Output Points | 4 points |
| Number of Test Output Points | 2 points (T0 corresponds to SI0 and SI2; T1 corresponds to SI1 and SI3.) |
| I/O Form | Sourcing output (PNP) |
| Input Current | 28.8 V |
| Maximum ON/OFF Response Time | 150 μs /150 μs |
| Fail-safe Principle | Switches safety outputs OFF (de-energized state) |
| Dimension | 12mm (W) × 100mm (H) × 80mm (D) |
| Weight | 70 g |
| Safety Integrity Level | SIL 3 |
|---|---|
| Performance Level | PL e |
| Category | Cat. 4 |
| Diagnostic Coverage | ≥ 99% |
| Safe Failure Fraction | ≥ 90% |
| Subsystem Element Type | Type B |
| Hardware Fault Tolerance | HFT = 1 |
| Proof Test Interval | ≥ 20 Years |
| PFHD | 1.67 E-10 |
| PFDavg | 1.43 E-5 |
| MTTFd | 145.9 Years |
| Typical applications | Industrial robotics, woodworking, printing, packaging, electronics assembly, and more |
|---|