Transducers and Measurement Accessories
Current sensors, clamp adaptors and transducers that connect to meters, loggers and analysers to extend what they can measure.
Products
-
Enquire about Rishabh CW 600
Rishabh CW 600 Open Loop Hall Effect Current Transducer, ±600 A
Open loop Hall effect current transducer for ±600 A nominal (±1800 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about Rishabh CW 850
Rishabh CW 850 Open Loop Hall Effect Current Transducer, ±850 A
Open loop Hall effect current transducer for ±850 A nominal (±2550 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about Rishabh CW 1000
Rishabh CW 1000 Open Loop Hall Effect Current Transducer, ±1000 A
Open loop Hall effect current transducer for ±1000 A nominal (±3000 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.
-
Enquire about Rishabh Ducer E13
Rishabh Ducer E13 3 Channel AC Current / Voltage Transducer
Three channel transducer: up to 3 AC current (to 10 A) or voltage (to 750 V) inputs converted to 3 isolated-from-supply DC current or voltage outputs; class 0.5, AC or DC auxiliary.
-
Enquire about Rishabh LTRC-1 80/30(50)
Rishabh LTRC-1 80/30(50) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-1 (80/30(50)), 60 A to 160 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-1 80/30(50) P
Rishabh LTRC-1 80/30(50) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-1 (80/30(50)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-2 90/50(40)
Rishabh LTRC-2 90/50(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-2 (90/50(40)), 200 A to 320 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-2 90/50(40) P
Rishabh LTRC-2 90/50(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-2 (90/50(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-3 110/72(40)
Rishabh LTRC-3 110/72(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-3 (110/72(40)), 400 A to 630 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-3 110/72(40) P
Rishabh LTRC-3 110/72(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-3 (110/72(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-4 135/85(40)
Rishabh LTRC-4 135/85(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-4 (135/85(40)), 800 A to 1250 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-4 135/85(40) P
Rishabh LTRC-4 135/85(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-4 (135/85(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-5 165/115(40)
Rishabh LTRC-5 165/115(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-5 (165/115(40)), 1500 A to 2000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-5 165/115(40) P
Rishabh LTRC-5 165/115(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-5 (165/115(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-6 195/130(40)
Rishabh LTRC-6 195/130(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-6 (195/130(40)), 2500 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-6 195/130(40) P
Rishabh LTRC-6 195/130(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-6 (195/130(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-7 230/165(40)
Rishabh LTRC-7 230/165(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-7 (230/165(40)), 3000 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-7 230/165(40) P
Rishabh LTRC-7 230/165(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-7 (230/165(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-8 295/200(40)
Rishabh LTRC-8 295/200(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-8 (295/200(40)), 4000 A to 5000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRC-8 295/200(40) P
Rishabh LTRC-8 295/200(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-8 (295/200(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Rishabh LTRP Series
Rishabh LTRP Series PU Resin Potted Busbar Current Transformer
Rish LTRP PU resin potted CTs with rectangular window for busbars, 50 A to 7500 A / 5 A, class 0.5, 1 or 3, transparent sealable terminal cover and primary direction marking.
-
Enquire about Rishabh Nano CT 63A
Rishabh Nano CT 63A Nano 3 Phase Current Transformer, 63 A / 100 mA
Compact Nano three phase CT for 63 A with 100 mA AC outputs and 1500 mm secondary cable, class 0.5, 0.1 VA; for circuit breaker and earth leakage installations.
-
Enquire about Rishabh Nano CT 125A
Rishabh Nano CT 125A Nano 3 Phase Current Transformer, 125 A / 100 mA
Compact Nano three phase CT for 125 A with 100 mA AC outputs and 1500 mm secondary cable, class 0.5, 0.1 VA; for circuit breaker and earth leakage installations.
-
Enquire about Rishabh Nano CT 250A
Rishabh Nano CT 250A Nano 3 Phase Current Transformer, 250 A / 100 mA
Compact Nano three phase CT for 250 A with 100 mA AC outputs and 1500 mm secondary cable, class 0.5, 0.1 VA; for circuit breaker and earth leakage installations.