Transducers and Measurement Accessories
Current sensors, clamp adaptors and transducers that connect to meters, loggers and analysers to extend what they can measure.
Products
-
Enquire about Kyoritsu KEW 8148
Kyoritsu KEW 8148 Leakage and Load Current Clamp Sensor, 68mm
Leakage and load current clamp sensor with a 68 mm jaw for the KEW 5010, 5020 and 6315. Not for power measurement.
-
Enquire about Lutron EMF-824
Lutron EMF-824 EMF Adapter with Separate Probe for Multimeters
Adapter that turns a digital multimeter on its DC 200 mV range into an EMF meter: 1 mV per milligauss, 30 to 300 Hz, single-axis separate probe.
-
Enquire about Minilec D5 PTW1
Minilec D5 PTW1 Active Power Transducer
Minilec D5 PTW1 active power transducer. Typical uses: cogeneration /captive power plants, control & relay panel, metering panels.
-
Enquire about Rishabh CON CV AVG
Rishabh CON CV AVG AC Voltage Transducer, 22.5 mm, Average
Narrow 22.5 mm AC voltage transducer, average (calibrated to RMS) sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about Kyoritsu KEW 8161
Kyoritsu KEW 8161 AC Clamp Sensor for Multimeters, 100A
AC clamp sensor that converts current into a voltage for a digital multimeter, for AC currents up to 100 A.
-
Enquire about Lutron LS-04
Lutron LS-04 Current Shunt, 200 A, for DM-9131
Current shunt for the DM-9131 car tester that gives 1 mV DC per ampere, so the meter can read DC currents up to 200 A.
-
Enquire about Minilec D5 PTW2
Minilec D5 PTW2 Reactive Factor Transducer
Minilec D5 PTW2 reactive factor transducer. Typical uses: cogeneration /captive power plants, control & relay panel, metering panels.
-
Enquire about Rishabh CON CV Dual
Rishabh CON CV Dual AC Voltage Transducer, Dual Output
Dual output AC voltage transducer, average (calibrated to RMS) sensing, two isolated outputs 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about Kyoritsu KEW 8177
Kyoritsu KEW 8177 Ior Leakage Current Clamp Sensor, 40mm
Ior leakage current clamp sensor with a 40 mm jaw, for use with the KEW 5050 Ior logger.
-
Enquire about Lutron ST-50
Lutron ST-50 Current Shunt, 50 A / 50 mV
Current shunt that extends a multimeter to 50 A AC or DC with a 1 mV per ampere output, with overload capacity of 100 A for one minute.
-
Enquire about Minilec D5 PTW3
Minilec D5 PTW3 Apparent Power Transducer
Minilec D5 PTW3 apparent power transducer. Typical uses: cogeneration /captive power plants, control & relay panel, metering panels.
-
Enquire about Rishabh CON CV TRMS
Rishabh CON CV TRMS AC Voltage Transducer, 22.5 mm, True RMS
Narrow 22.5 mm AC voltage transducer, true RMS sensing, one output 0…10 mA, 0…20 mA, 2…10 mA, 4…20 mA, 0…5 V, 0…10 V, class 0.2, wide auxiliary supply.
-
Enquire about Kyoritsu KEW 8178
Kyoritsu KEW 8178 Ior Leakage Current Clamp Sensor, 68mm
Ior leakage current clamp sensor with a 68 mm jaw, for use with the KEW 5050 Ior logger.
-
Enquire about Rishabh CON Hz
Rishabh CON Hz Programmable Frequency Transducer
Frequency transducer for 45-55, 48-52, 55-65 or 45-65 Hz on 57-500 V inputs, single or dual 0/4-20 mA or 0-10 V outputs, class 0.2, optional LCD and RS485.
-
Enquire about Kyoritsu KEW 8309
Kyoritsu KEW 8309 Voltage Sensor for Floating Voltage
Voltage sensor for the KEW 5020 logger that measures floating (ungrounded phase-to-phase) voltage. The KEW 5020-01 set is the logger supplied with one KEW 8309.
-
Enquire about Rishabh CON I
Rishabh CON I Programmable AC Current Transducer
Programmable true RMS AC current transducer, class 0.2, with single or dual isolated 0/4-20 mA or 0-10 V outputs; programmed on site via optional LCD or RS485 Modbus.
-
Enquire about Rishabh CON I11
Rishabh CON I11 Self Powered AC Current Transducer
Self powered AC current transducer: 1 A or 5 A input to 0-1/5/10/20 mA, 4-20 mA or 0-10 V output, class 0.5, response under 200 ms; DIN rail or wall mounting.
-
Enquire about Rishabh CON M
Rishabh CON M Multi Transducer with Analog / Relay Outputs
Programmable 3 phase multi transducer for V, I, power, PF, frequency, energy and THD with 4 analog, 4 relay or 2 analog + 2 relay outputs, RS485 Modbus and USB; ±0.2% V / I.
-
Enquire about Rishabh CON M+
Rishabh CON M+ Programmable Multi-function Transducer
4-in-1 programmable multi-function transducer for 1 or 3 phase systems: up to 4 isolated analog outputs and 2 relays, class 0.2 analog, class 0.5S energy, THD to 31st, RS485 and USB.
-
Enquire about Rishabh CON P
Rishabh CON P Programmable Power Transducer
Programmable active, reactive and apparent power, phase angle and power factor transducer for 1 or 3 phase balanced / unbalanced systems; class 0.2, 1 or 2 outputs, LCD and RS485 options.
-
Enquire about Rishabh CON V
Rishabh CON V Programmable AC Voltage Transducer
Programmable true RMS AC voltage transducer, class 0.2, with single or dual isolated 0/4-20 mA or 0-10 V outputs; programmed on site via optional LCD or RS485 Modbus.
-
Enquire about Rishabh CT Ducer 70x30
Rishabh CT Ducer 70x30 Current Transformer with Transducer, 70 x 30 mm
CT and transducer in one 70 x 30 mm window unit: AC current 50 A to 300 A to 4-20 mA or 0-20 mA DC, TRMS or average versions, class 0.5, spring clamp terminals.
-
Enquire about Rishabh CT Ducer 90x40
Rishabh CT Ducer 90x40 Current Transformer with Transducer, 90 x 40 mm
CT and transducer in one 90 x 40 mm window unit: AC current 50 A to 750 A to 4-20 mA or 0-20 mA DC, TRMS or average versions, class 0.5, spring clamp terminals.
-
Enquire about Rishabh CW 500
Rishabh CW 500 Open Loop Hall Effect Current Transducer, ±500 A
Open loop Hall effect current transducer for ±500 A nominal (±1500 A range), AC to 25 kHz, DC or pulsating DC, with ±4 V isolated output and ±15 V supply; 64 x 21 mm busbar aperture.