Test & Measuring Instruments
Portable and bench instruments for electricians, maintenance teams, test labs and quality departments: from multimeters and clamp meters to insulation, earth, power quality and environmental testers.
All products in Test & Measuring Instruments
-
Enquire about Hioki RM3543
Hioki RM3543 Resistance HiTester
Resistance meter for shunts down to 0.1 mΩ: 0.01 μΩ resolution, ±0.16% accuracy, contact check, comparator and data export for automated systems; test fixtures sold separately.
-
Enquire about Meco VBSM6129B+
Meco VBSM6129B+ Vehicle Battery System Tester, 12 V
Vehicle battery and electrical system tester for 12 V batteries of 3 – 250 Ah: CCA / EN 100 – 1700, SOC, SOH, internal resistance and load tests.
-
Enquire about Kusam Meco KM-VC-5300
Kusam Meco KM-VC-5300 Digital Vernier Caliper, 300 mm
Hardened stainless steel digital vernier caliper, 0 – 300 mm, 0.01 mm / 0.0005 inch resolution, ±0.04 mm: outer and inner diameter, depth and step; sealed against water, oil and coolant; IP54.
-
Enquire about Lutron EMF-819
Lutron EMF-819 3-axis RF Electromagnetic Field Meter, 50 MHz to 3 GHz
Broadband three-axis RF field meter for 50 MHz to 3 GHz, reading V/m, W/m² and mW/cm², supplied with the EP-05H probe.
-
Enquire about Rishabh LTRC-4 135/85(40) P
Rishabh LTRC-4 135/85(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-4 (135/85(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Fluke AC220
Fluke AC220 SureGrip Alligator Clips
Insulated SureGrip alligator clips with nickel-plated jaws for round screw heads up to 9.5 mm.
-
Enquire about CIE CIE/7100
CIE CIE/7100 Transformer Oil Test Set 0-100kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about Hioki RM3543-01
Hioki RM3543-01 Resistance HiTester with GP-IB
Resistance meter for shunts down to 0.1 mΩ: 0.01 μΩ resolution, ±0.16% accuracy, contact check, comparator and data export for automated systems; test fixtures sold separately. Built-in GP-IB interface.
-
Enquire about Meco VBSM6246
Meco VBSM6246 Vehicle Battery System Tester, 12 / 24 V
Vehicle battery and electrical system tester for 12 / 24 V batteries, CCA 100 – 1700 with IEC / EN / DIN conversion, bad cell detection; CAT III 600 V.
-
Enquire about Kusam Meco KM 01
Kusam Meco KM 01 Analog Insulation Resistance Tester, 100 V / 50 MΩ
Battery-powered analog insulation tester with 100 V DC test voltage and 0 – 50 MΩ logarithmic mirror scale, 600 V AC voltage range to check for live circuits, test-voltage lock and HV LED; ABS case.
-
Enquire about Lutron EMF-822A
Lutron EMF-822A EMF Tester, Single Axis
Hand-held EMF tester for power-frequency magnetic fields from 30 to 300 Hz, reading in micro Tesla or milli Gauss.
-
Enquire about Rishabh LTRC-5 165/115(40)
Rishabh LTRC-5 165/115(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-5 (165/115(40)), 1500 A to 2000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about Fluke AC280
Fluke AC280 SureGrip Hook Clips
SureGrip hook clips (red and black) narrowing to 5.6 mm at the tip, for secure connections in tight spots.
-
Enquire about CIE CIE/7100 MOT
CIE CIE/7100 MOT Transformer Oil Test Set 0-100kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about Hioki RM3544
Hioki RM3544 Resistance Meter
Resistance meter with 0.02% basic accuracy and 30 mΩ to 3 MΩ ranges (1 μΩ resolution, 300 mA max.), with temperature correction for copper wiring. No interfaces.
-
Enquire about Meco VBSM6246P
Meco VBSM6246P Vehicle Battery System Tester with Printer, 12 / 24 V
Vehicle battery system tester with built-in thermal printer for 12 / 24 V batteries: CCA 100 – 1700, engine activation load test, bad cell detection.
-
Enquire about Kusam Meco KM 03
Kusam Meco KM 03 Analog Insulation Resistance Tester, 500 V / 100 MΩ
Battery-powered analog insulation tester with 500 V DC test voltage and 0 – 100 MΩ logarithmic mirror scale, 600 V AC voltage range to check for live circuits, test-voltage lock and HV LED; ABS case.
-
Enquire about Lutron EMF-823
Lutron EMF-823 EMF Tester, 3 Ranges
EMF tester for 30 to 300 Hz magnetic fields with 20, 200 and 2,000 µT (200 to 20,000 mG) ranges.
-
Enquire about Rishabh LTRC-5 165/115(40) P
Rishabh LTRC-5 165/115(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-5 (165/115(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about Fluke AC285
Fluke AC285 SureGrip Large Alligator Clips
Large SureGrip alligator clips (red and black) with nickel-plated steel jaws for wires to 20 mm bolts.
-
Enquire about CIE CIE/7120
CIE CIE/7120 Transformer Oil Test Set 0-120kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about Hioki RM3544-01
Hioki RM3544-01 Resistance Meter with Interfaces
Resistance meter with 0.02% basic accuracy and 30 mΩ to 3 MΩ ranges (1 μΩ resolution, 300 mA max.), with temperature correction for copper wiring. EXT I/O, RS-232C and USB built in.
-
Enquire about Meco VCG-09
Meco VCG-09 Voltage and Current Signal Generator, Pocket Size
Pocket voltage and current signal generator with LED display and rotary knob, powered by 9 – 30 V DC, micro-USB 5 V or optional Li-ion battery.
-
Enquire about Kusam Meco KM 031
Kusam Meco KM 031 600 A AC True RMS Clamp Meter with AmpTip and EF Detection
600 A AC true RMS clamp meter with slim 26 mm jaw and AmpTip™ for 0.01 A – 60 A, 5 ms crest capture, BeepLit™ continuity and non-contact / probe EF detection; CAT III 600 V / CAT IV 300 V.