Hioki RM3543-01 Resistance HiTester with GP-IB

Brand
Hioki
Model number
RM3543-01

Resistance meter for shunts down to 0.1 mΩ: 0.01 μΩ resolution, ±0.16% accuracy, contact check, comparator and data export for automated systems; test fixtures sold separately. Built-in GP-IB interface.

Price and availability on request

Request a quote

Sent with the product details: Hioki RM3543-01 Resistance HiTester with GP-IB.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Advanced enough to measure 0.1 mΩ shunts with room to spare at ±0.16% accuracy & 0.01μΩ resolution performance
  • Superb repeatable measurement accuracy
  • Advanced contact-check, comparator, and data export functions
  • Intuitive user interface and strong noise immunity are ideal for automated systems

Specifications

Specifications
Measurement methodFour-terminal, constant-current DC
Resistance range10 mΩ (Max. 12.00000 mΩ, 0.01 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 7 steps
DisplayMonochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy[at 10 mΩ range, with SLOW mode, average 16 times settings] ±0.060 % rdg. ±0.001 % f.s.
Testing current[at 10 mΩ range] 1 A DC to [at 1000 Ω range] 1 mA DC
Open-terminal voltage20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 MΩ)
Sampling rateFAST, MEDIUM, SLOW, 3 settings
Integration time[at 10 mΩ range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC, Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period)
Other functionsComparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
InterfacesExternal I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
External I/OTrigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
Power supply100 to 240 V AC, 50/60 Hz, 40 VA max.
Dimensions and mass260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)
Supplied with
ContentsPower cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1
Ordering
Order codeRM3543-01 (Built in GP-IB interface)
NoteTest fixtures are not supplied with the unit. Select an optional test fixture when ordering.

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering.