Automation, Drives & PLC
Drives, controllers, panel meters, relays and accessories for control panels and machines. Choose a category, or send us your panel requirement and we will suggest suitable models.
All products in Automation, Drives & PLC
-
Enquire about Minilec S2 CMR1
Minilec S2 CMR1 Motor / Pump Protection Relay
Minilec S2 CMR1 motor / pump protection relay with 2 CO output. Typical uses: air -conditioning & refrigeration machines, crusher motors , mining m/c, screw compressors.
-
Enquire about Kusam Meco TW2S
Kusam Meco TW2S Current Loop Isolating Supply Transmitter, Dual Input and Dual Output
Two-channel loop supply isolator: powers two 2-wire 4 – 20 mA transmitters (24 V) and gives two isolated DC outputs, ±0.1%, DIN rail.
-
Enquire about Autonics BD-CRS
Autonics BD-CRS Laser Displacement Sensor Communication Converter BD-CRS
Autonics BD-CRS laser displacement sensor communication converter (BD-C Series): IP40 (IEC standard). Order code note: 12-30VDC.
-
Enquire about Selec ELCTR35-1-30mA
Selec ELCTR35-1-30mA Earth Leakage Relay with Built-in CBCT ELCTR35-1-30mA
Selec ELCTR35-1-30mA earth leakage relay with built-in CBCT: measures Monitors True RMS Earth Leakage Current, output 1 C/O (SPDT ), 230V AC (±15%) supply, 74mm, DIN rail mount.
-
Enquire about Delta DVP-ES3/ES2 Expansion Modules
Delta DVP-ES3/ES2 Expansion Modules DVP-ES3 / ES2 Expansion Modules
Right-side modules for ES3 and ES2 PLCs: 8, 16 and 32-point digital I/O, 4 and 6-channel 14-bit analog I/O, RTD and thermocouple temperature modules, and resolver modules.
-
Enquire about Rishabh DPM 72x144 AC 4½D
Rishabh DPM 72x144 AC 4½D 4½ Digit 1 Phase AC Ammeter / Voltmeter, 72 x 144 mm, 1 inch Display
4½ digit single phase AC ammeter (1 A / 5 A) or voltmeter (110 V, 240 V, 500 V), 72 x 144 mm, with 26 mm digits, 45-65 Hz or 400 Hz versions; accuracy 1% (0.5% optional).
-
Enquire about Unison UNI 901 MCPHT 48 50 420 AL5
Unison UNI 901 MCPHT 48 50 420 AL5 SCR Power Controller 901, Phase Angle, 50 A
Microcontroller-based SCR power controller with phase-angle firing worked out for 1% accuracy, driving 50 A loads on 90-480 V AC supplies (detected automatically) from a 4-20 mA or 0-10 V DC signal.
-
Enquire about Veritek VIPS 98I
Veritek VIPS 98I Earth Leakage Relay with Built-in CBCT
Earth leakage relay with built-in 25 mm CBCT, fixed 30 / 100 / 300 mA trip (factory set), instantaneous trip under 100 ms.
-
Enquire about Multispan PC-1044
Multispan PC-1044 Programmable Counter
Panel programmable counter for proximity or micro switch input, with separate process and set count displays, one relay with two changeover contacts and auto or manual reset.
-
Enquire about Meco MLC96
Meco MLC96 AC Moving Coil Rectifier DIN Panel Ammeter / Voltmeter
AC moving coil rectifier DIN panel ammeter / voltmeter, 90° or 240° deflection, 1 mA – 5 A or 10 – 1000 V direct, ±1.5% of full scale.
-
Enquire about Adi-Artech PT-100-mA
Adi-Artech PT-100-mA Pressure Sensor with Current Output
Adi-Artech strain gauge pressure sensor, with 4-20 mA output, SS 17-4 PH stainless steel, IP65. For hydraulic, pneumatic and process pressure measurement.
-
Enquire about Minilec S2 CMR3
Minilec S2 CMR3 Earth Fault / Earth Leakage Relay
Minilec S2 CMR3 earth fault / earth leakage relay with 2 CO output. Typical uses: generator panels, AMF panels, MCC panels, synchronizing control panels.
-
Enquire about Kusam Meco TWD
Kusam Meco TWD DC Isolating Transmitter
DC signal isolator: one DC input (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) to one isolated output, ±0.1%, ≤ 400 ms, 27 mm DIN rail housing.
-
Enquire about Autonics BEN3M-PDT
Autonics BEN3M-PDT Universal AC / DC Photoelectric Sensor BEN3M-PDT
Autonics BEN3M-PDT universal AC / DC photoelectric sensor (BEN Series): sensing distance 0.1 to 3 m, Polarized retroreflective, ≤ 200 mA, IP50 (IEC standard). Order code note: DC12-24V.
-
Enquire about Selec ELCTR35-1-300mA
Selec ELCTR35-1-300mA Earth Leakage Relay with Built-in CBCT ELCTR35-1-300mA
Selec ELCTR35-1-300mA earth leakage relay with built-in CBCT: measures Monitors True RMS Earth Leakage Current, output 1 C/O (SPDT ), 230V AC (±15%) supply, 74mm, DIN rail mount.
-
Enquire about Delta DVP-EX
Delta DVP-EX PLC with Analog I/O, 4K Steps
Low-cost PLC with 8 DI / 6 DO and 4 AI / 2 AO built in, up to 238 I/O, 4K steps, RS-232 and RS-485 with Modbus, and two 10 kHz pulse outputs. Discontinued 2018; replaced by DVP-EX2.
-
Enquire about Rishabh DPM 72x144 DC 4½D
Rishabh DPM 72x144 DC 4½D 4½ Digit DC Ammeter / Voltmeter, 72 x 144 mm, 1 inch Display
4½ digit DC ammeter or voltmeter, 72 x 144 mm, with 26 mm (1 inch) digits: 0-20 / 4-20 mA, mV or up to 1000 V DC inputs, 19999 count, accuracy 0.1% of range + 1 digit.
-
Enquire about Unison UNI 901 MCPHT 48 90 420 CU2
Unison UNI 901 MCPHT 48 90 420 CU2 SCR Power Controller 901, Phase Angle, 90 A
Microcontroller-based SCR power controller with phase-angle firing worked out for 1% accuracy, driving 90 A loads on 90-480 V AC supplies (detected automatically) from a 4-20 mA or 0-10 V DC signal.
-
Enquire about Veritek VIPS 98L
Veritek VIPS 98L Earth Leakage Relay with Display
Earth leakage relay with LCD leakage current display and bar graph, 10 mA – 30 A, pre-alarm, two relays, CBCT open-circuit detection.
-
Enquire about Multispan PC-6006
Multispan PC-6006 Jumbo Display Programmable Counter
Large-display programmable counter with 4 or 6 digits of 4-inch red LEDs on one or both sides, for proximity or micro switch input, with relay output. For production counts visible across the floor.
-
Enquire about Meco MLC110
Meco MLC110 AC Moving Coil Rectifier DIN Panel Ammeter / Voltmeter
AC moving coil rectifier DIN panel ammeter / voltmeter, 90° or 240° deflection, 1 mA – 5 A or 10 – 1000 V direct, ±1.5% of full scale.
-
Enquire about Adi-Artech QAS-200
Adi-Artech QAS-200 Quad Axis Force / Torque Sensor
Adi-Artech strain gauge quad axis force / torque sensor, 5000 N & 200 NM for tension and compression, in nickel-plated tool steel, IP65 sealed. For engine test dynamometer, impact measurement, medical instrumentation.
-
Enquire about Minilec S2 CMR5
Minilec S2 CMR5 Current Monitoring Relay
Minilec S2 CMR5 current monitoring relay. Typical uses: generator panels / AMF panels, fan belt failure monitoring, dry run of pumps.
-
Enquire about Kusam Meco TWD2
Kusam Meco TWD2 DC Isolating Transmitter, Dual Output
DC signal isolator: one DC input (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) to two isolated outputs, ±0.1%, ≤ 400 ms, 27 mm DIN rail housing.