Automation, Drives & PLC
Drives, controllers, panel meters, relays and accessories for control panels and machines. Choose a category, or send us your panel requirement and we will suggest suitable models.
All products in Automation, Drives & PLC
-
Enquire about Delta DVP-PM Expansion Modules
Delta DVP-PM Expansion Modules DVP-PM Expansion Modules
Modules for DVP-PM controllers: 8 to 48-point digital I/O, 4 and 6-channel analog I/O, RTD and thermocouple temperature modules, and DeviceNet, PROFIBUS-DP and CANopen network modules.
-
Enquire about Rishabh DPM Hz 72x144
Rishabh DPM Hz 72x144 Frequency and RPM Digital Panel Meter, 72 x 144 mm
Digital frequency meter, 72 x 144 mm, for 10 Hz to 500 Hz on 50-500 V L-N inputs, also shows RPM from the set number of poles; ±0.5 Hz accuracy.
-
Enquire about Unison UNI 901 MOD TC ONF 60 90 485 CU2 CT60 JK HO
Unison UNI 901 MOD TC ONF 60 90 485 CU2 CT60 JK HO Temperature Control SSR 901, Modbus RS-485, Heat Only, 90 A
Solid state relay with a built-in PID temperature controller for heating, J or K thermocouple input, a Modbus RTU RS-485 link to an HMI or PLC and a CT input for load-failure alarms; 90 A at 24-600 V AC.
-
Enquire about Veritek VIPS 98P
Veritek VIPS 98P Earth Leakage Relay, DIN Rail
DIN-rail earth leakage relay with leakage shown as % of range, 0.03 – 30 A settings, CBCT open-circuit detection, IEC 60947-2.
-
Enquire about Multispan PI-38
Multispan PI-38 Process Indicator
4-digit process indicator for 4-20 mA, 0-20 mA or 0-10 V signals, with up to 3-digit resolution. 48 x 96 mm panel size; other sizes available.
-
Enquire about Meco MQ96
Meco MQ96 DC Moving Coil DIN Panel Ammeter / Voltmeter
DC moving coil DIN panel ammeter / voltmeter, 90° or 240° deflection, from 100 µA to 50 A direct and 50 mV to 1000 V; higher currents with external shunt.
-
Enquire about Adi-Artech TAS-200-2
Adi-Artech TAS-200-2 Tri Axis Force Sensor
Adi-Artech strain gauge tri axis force sensor, 5 KN - X, Y Axis & 20 KN - Z Axis for tension and compression, in nickel-plated tool steel, IP65 sealed. For automotive research, medical instrumentation, multi axial forces in lathe operation.
-
Enquire about Minilec S2 DELR
Minilec S2 DELR Phase Failure Relay
Minilec S2 DELR phase failure relay with (1 CO + 1 CO) / 2 CO output. Typical uses: hoist motor control, 3 ph. split AC machines, agricultural pump starters.
-
Enquire about Kusam Meco TWH
Kusam Meco TWH High Selector Isolating Transmitter
High selector: compares two DC inputs (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) and passes the higher one to an isolated DC output, ±0.1%, DIN rail.
-
Enquire about Autonics BEN10M-TDT
Autonics BEN10M-TDT Universal AC / DC Photoelectric Sensor BEN10M-TDT
Autonics BEN10M-TDT universal AC / DC photoelectric sensor (BEN Series): sensing distance 10 m, Through-beam, Relay contact output, IP50 (IEC standard). Order code note: DC12-24V.
-
Enquire about Selec EXP FLEX 2M
Selec EXP FLEX 2M Expansion Module EXP FLEX 2M
Selec EXP FLEX 2M expansion module: 18 to 30 VDC supply, RS485 Proprietary Protocol, 35 x 90mm, DIN rail.
-
Enquire about Delta DVP-SA2
Delta DVP-SA2 Slim Advanced PLC
Slim PLC with 8 DI / 4 DO, up to 492 I/O, 16k steps, RS-232 and two RS-485 ports and 100 kHz pulse output and counting; takes up to 8 modules such as analog, temperature or PROFIBUS.
-
Enquire about Rishabh DPM Hz 96x96
Rishabh DPM Hz 96x96 Frequency and RPM Digital Panel Meter, 96 x 96 mm
Digital frequency meter, 96 x 96 mm, for 10 Hz to 500 Hz on 50-500 V L-N inputs, also shows RPM from the set number of poles; ±0.5 Hz accuracy.
-
Enquire about Unison UNI 901 MOD TC ONF 60 200 485 CU2 CT60 JK HC
Unison UNI 901 MOD TC ONF 60 200 485 CU2 CT60 JK HC Temperature Control SSR 901, Modbus RS-485, Heat and Cool, 200 A
Solid state relay with a built-in PID temperature controller for heating and cooling, J or K thermocouple input, a Modbus RTU RS-485 link to an HMI or PLC and a CT input for load-failure alarms; 200 A at 24-600 V AC.
-
Enquire about Veritek VIPS 98PF
Veritek VIPS 98PF Earth Leakage Relay, Panel Mount
Panel-mount earth leakage relay with leakage shown as % of setting, 0.03 – 30 A settings, CBCT open-circuit detection, IEC 60947-2.
-
Enquire about Multispan PIC-38
Multispan PIC-38 Process Controller
4-digit process controller for 4-20 mA, 0-20 mA or 0-10 V signals, with built-in sensor supply, up to two relays, analog retransmission and RS-485 Modbus. 48 x 96 mm; other sizes available.
-
Enquire about Meco MR60
Meco MR60 Rectangular DC Panel Meter, Clear Acrylic
Clear acrylic rectangular DC panel meter, moving coil, ±2.5% of full scale; µA, mA, A (shunt) and mV / V ranges.
-
Enquire about Adi-Artech TSB
Adi-Artech TSB Tension Sensing Block
Adi-Artech strain gauge tension sensing block, 75 to 1500 Kgf for tension loads, in tool steel, IP65 sealed. For paper, foil, magnetic tape.
-
Enquire about Minilec S2 DMPR
Minilec S2 DMPR Phase Failure Relay
Minilec S2 DMPR phase failure relay with 2 CO output. Typical uses: hoist motor control, 3 ph. split AC machines, agricultural pump starters.
-
Enquire about Kusam Meco TWL
Kusam Meco TWL Low Selector Isolating Transmitter
Low selector: compares two DC inputs (DC 0 – 10 mA, 0 – 20 mA, 4 – 20 mA, 0 – 5 V, 1 – 5 V or 0 – 10 V) and passes the lower one to an isolated DC output, ±0.1%, DIN rail.
-
Enquire about Autonics BEN10M-TFR
Autonics BEN10M-TFR Universal AC / DC Photoelectric Sensor BEN10M-TFR
Autonics BEN10M-TFR universal AC / DC photoelectric sensor (BEN Series): sensing distance 10 m, Through-beam, Relay contact output, IP50 (IEC standard). Order code note: (7M)DC24-240V/AC24-240V.
-
Enquire about Selec FD600
Selec FD600 Vector Control AC Drive FD600
Selec FD600 vector control AC drive: input 3-Phase AC 380 V - 450V, −15% to +20%, output 0–Input Voltage, Modbus RS485.
-
Enquire about Delta DVP-SE
Delta DVP-SE Slim Network PLC
Network-type slim PLC with 8 DI / 4 DO, built-in mini USB, Ethernet (Modbus TCP and EtherNet/IP) and 2 RS-485 ports, 16k steps, IP filter and a real-time clock that runs 15 days without power.
-
Enquire about Rishabh DPM PF 72x144
Rishabh DPM PF 72x144 4 Digit Power Factor DPM, 72 x 144 mm
4 digit power factor DPM, 72 x 144 mm, for single phase, 3 phase 3 wire or 4 wire networks: 0.1 lag...1...0.1 lead, accuracy ±2°; fixed 1 A or 5 A CT input.