Rishabh
471 Rishabh products listed. For prices and availability, send an enquiry.
Products
-
Enquire about LM1360+
LM1360+ Multifunction Energy Meter, 1 A / 5 A CT Input
Panel mounted 96 x 96 multifunction energy meter with class 0.5S (0.2S optional) energy, harmonics to 31st, load management, digital inputs / outputs and RS485, Ethernet, BACnet or data logging options.
-
Enquire about LM1360+ RJ12
LM1360+ RJ12 Multifunction Energy Meter, RJ12 CT Input
LM1360+ multifunction energy meter for plug-and-play RJ12 (100 mA) CTs: class 1 energy, harmonics to 31st, data logging, load management, with RS485, Ethernet or BACnet options.
-
Enquire about LM1380
LM1380 Multifunction Energy Meter, Class 0.2S, Harmonics to 63rd
LM1380 96 x 96 multifunction meter with class 0.2S energy, harmonics to 63rd, 4 digital inputs, 2 relay outputs and RS485, Ethernet or BACnet IP options; IEC 61557-12.
-
Enquire about LTRC-1 80/30(50)
LTRC-1 80/30(50) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-1 (80/30(50)), 60 A to 160 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-1 80/30(50) P
LTRC-1 80/30(50) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-1 (80/30(50)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-2 90/50(40)
LTRC-2 90/50(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-2 (90/50(40)), 200 A to 320 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-2 90/50(40) P
LTRC-2 90/50(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-2 (90/50(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-3 110/72(40)
LTRC-3 110/72(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-3 (110/72(40)), 400 A to 630 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-3 110/72(40) P
LTRC-3 110/72(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-3 (110/72(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-4 135/85(40)
LTRC-4 135/85(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-4 (135/85(40)), 800 A to 1250 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-4 135/85(40) P
LTRC-4 135/85(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-4 (135/85(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-5 165/115(40)
LTRC-5 165/115(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-5 (165/115(40)), 1500 A to 2000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-5 165/115(40) P
LTRC-5 165/115(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-5 (165/115(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-6 195/130(40)
LTRC-6 195/130(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-6 (195/130(40)), 2500 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-6 195/130(40) P
LTRC-6 195/130(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-6 (195/130(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-7 230/165(40)
LTRC-7 230/165(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-7 (230/165(40)), 3000 A to 3200 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-7 230/165(40) P
LTRC-7 230/165(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-7 (230/165(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRC-8 295/200(40)
LTRC-8 295/200(40) Resin Cast Metering Current Transformer
Epoxy resin cast metering CT LTRC-8 (295/200(40)), 4000 A to 5000 A primary, 5 A or 1 A secondary, class 0.5 or 1, transparent terminal cover, wall mounting.
-
Enquire about LTRC-8 295/200(40) P
LTRC-8 295/200(40) P Resin Cast Protection Current Transformer
Epoxy resin cast protection CT LTRC-8 (295/200(40)), class 5P with accuracy limit factor 5 or 10, 5 A or 1 A secondary, transparent terminal cover, wall mounting.
-
Enquire about LTRP Series
LTRP Series PU Resin Potted Busbar Current Transformer
Rish LTRP PU resin potted CTs with rectangular window for busbars, 50 A to 7500 A / 5 A, class 0.5, 1 or 3, transparent sealable terminal cover and primary direction marking.
-
Enquire about Master 3440
Master 3440 Multifunction Meter
Rish Master 3440 multifunction TRMS meter with 3 line 4 digit led display, more than 61 parameters, class 1.0 (0.5 / 0.2 on request), RS485, pulse, analog or Ethernet options.
-
Enquire about Master 3440 Class 0.2S
Master 3440 Class 0.2S Multifunction Meter, Class 0.2S
Rish Master 3440 class 0.2S multifunction meter (IEC 62053-22) with harmonics to 31st and RS485 + 2 relays, RS485 + relay + 2 analog outputs or Ethernet options.
-
Enquire about Master 3440i
Master 3440i Touch Screen Multifunction Meter
Rish Master 3440i multifunction TRMS meter with touch screen graphics lcd display, more than 46 parameters, class 1.0 (0.5 / 0.2 on request), RS485, pulse, analog or Ethernet options.
-
Enquire about Master 3440i Class 0.2S
Master 3440i Class 0.2S Touch Screen Multifunction Meter, Class 0.2S
Rish Master 3440i class 0.2S multifunction meter with 320 x 240 colour touch screen, harmonics to 31st, RS485, relay, analog or Ethernet options.