CIE
186 CIE products listed. For prices and availability, send an enquiry.
Products
-
Enquire about CIE/777HM 2500V 5000MΩ
CIE/777HM 2500V 5000MΩ Insulation Tester 2500 V, 5,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 2500 V, scaled 0 to 5000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 2500V 10000MΩ
CIE/777HM 2500V 10000MΩ Insulation Tester 2500 V, 10,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 2500 V, scaled 0 to 10000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 2500V 20000MΩ
CIE/777HM 2500V 20000MΩ Insulation Tester 2500 V, 20,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 2500 V, scaled 0 to 20000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 5000V 50-50000MΩ
CIE/777HM 5000V 50-50000MΩ Insulation Tester 5000 V, 50-50,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 5000 V, scaled 50 to 50000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 5000V 100-100000MΩ
CIE/777HM 5000V 100-100000MΩ Insulation Tester 5000 V, 100-1,00,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 5000 V, scaled 100 to 100000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 5000V 5000MΩ
CIE/777HM 5000V 5000MΩ Insulation Tester 5000 V, 5,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 5000 V, scaled 0 to 5000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 5000V 10000MΩ
CIE/777HM 5000V 10000MΩ Insulation Tester 5000 V, 10,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 5000 V, scaled 0 to 10000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 5000V 20000MΩ
CIE/777HM 5000V 20000MΩ Insulation Tester 5000 V, 20,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 5000 V, scaled 0 to 20000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 10000V 50-50000MΩ
CIE/777HM 10000V 50-50000MΩ Insulation Tester 10000 V, 50-50,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 10000 V, scaled 50 to 50000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 10000V 100-100000MΩ
CIE/777HM 10000V 100-100000MΩ Insulation Tester 10000 V, 100-1,00,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 10000 V, scaled 100 to 100000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 10000V 10000MΩ
CIE/777HM 10000V 10000MΩ Insulation Tester 10000 V, 10,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 10000 V, scaled 0 to 10000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/777HM 10000V 20000MΩ
CIE/777HM 10000V 20000MΩ Insulation Tester 10000 V, 20,000 MΩ, Motor cum Hand Driven, Wooden Body
CIE/777HM mains or hand-driven insulation tester at 10000 V, scaled 0 to 20000 MΩ, with mirror scale, guard terminal and wooden cabinet; suits PI and DAR tests. IS 2992:1987.
-
Enquire about CIE/7050
CIE/7050 Transformer Oil Test Set 0-50kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7050 MOT
CIE/7050 MOT Transformer Oil Test Set 0-50kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7060
CIE/7060 Transformer Oil Test Set 0-60kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7060 MOT
CIE/7060 MOT Transformer Oil Test Set 0-60kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7070
CIE/7070 Transformer Oil Test Set 0-70kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7070 MOT
CIE/7070 MOT Transformer Oil Test Set 0-70kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7080
CIE/7080 Transformer Oil Test Set 0-80kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7080 MOT
CIE/7080 MOT Transformer Oil Test Set 0-80kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7100
CIE/7100 Transformer Oil Test Set 0-100kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7100 MOT
CIE/7100 MOT Transformer Oil Test Set 0-100kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7120
CIE/7120 Transformer Oil Test Set 0-120kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7120 MOT
CIE/7120 MOT Transformer Oil Test Set 0-120kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.