CIE
15 CIE products listed in this category. For prices and availability, send an enquiry.
Products
-
Enquire about CIE-RTS-5
CIE-RTS-5 Relay Test Set, Secondary Current Injection, 400 VA
Portable secondary injection set for protection relays: continuously variable current up to 200 A for short periods (0-1 A to 0-100 A ranges), 0-230 V AC output, fixed 50 V and 110 V, digital meters and timer.
-
Enquire about CIE-RTS-5A
CIE-RTS-5A Relay Test Set, Secondary Current Injection, 1000 VA
Portable 1000 VA secondary injection set for protection relays: variable current to 100 A (200 A for 30 s), plus 0-230 V AC or 0-240 V DC variable output, digital meters, dual-range timer and NO/NC contacts.
-
Enquire about CIE-RTS-33
CIE-RTS-33 Three Phase Relay Test Set
Three phase relay test set with variable current injection in 0-1 / 5 / 10 / 25 / 50 A ranges, 110 V phase-to-phase and 63.5 V phase-to-neutral voltages, fixed 30, 110 and 220 V DC outputs and phase angle control.
-
Enquire about CIE/7050
CIE/7050 Transformer Oil Test Set 0-50kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7050 MOT
CIE/7050 MOT Transformer Oil Test Set 0-50kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7060
CIE/7060 Transformer Oil Test Set 0-60kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7060 MOT
CIE/7060 MOT Transformer Oil Test Set 0-60kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7070
CIE/7070 Transformer Oil Test Set 0-70kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7070 MOT
CIE/7070 MOT Transformer Oil Test Set 0-70kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7080
CIE/7080 Transformer Oil Test Set 0-80kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7080 MOT
CIE/7080 MOT Transformer Oil Test Set 0-80kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7100
CIE/7100 Transformer Oil Test Set 0-100kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7100 MOT
CIE/7100 MOT Transformer Oil Test Set 0-100kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7120
CIE/7120 Transformer Oil Test Set 0-120kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE/7120 MOT
CIE/7120 MOT Transformer Oil Test Set 0-120kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.