Transformer & Breaker Test Equipment
Test sets for transformers and switchgear, such as transformer oil breakdown (BDV) testers and related equipment for substation maintenance.
Products
-
Enquire about CIE CIE-RTS-5
CIE CIE-RTS-5 Relay Test Set, Secondary Current Injection, 400 VA
Portable secondary injection set for protection relays: continuously variable current up to 200 A for short periods (0-1 A to 0-100 A ranges), 0-230 V AC output, fixed 50 V and 110 V, digital meters and timer.
-
Enquire about Metrel MI 3242
Metrel MI 3242 MicroOhm 2A Low Resistance Ohmmeter
Handheld 4-wire micro-ohmmeter with 2 A, 100 mA and 10 mA test currents: 1 µΩ resolution, 9.999 mΩ to 199.9 Ω ranges, ±(0.25 % of reading + 2 digits); also measures voltage and frequency.
-
Enquire about CIE CIE-RTS-5A
CIE CIE-RTS-5A Relay Test Set, Secondary Current Injection, 1000 VA
Portable 1000 VA secondary injection set for protection relays: variable current to 100 A (200 A for 30 s), plus 0-230 V AC or 0-240 V DC variable output, digital meters, dual-range timer and NO/NC contacts.
-
Enquire about Metrel MI 3250
Metrel MI 3250 MicroOhm 10A Low Resistance Ohmmeter
Portable micro-ohmmeter with test currents from 1 mA to 10 A: 0.1 µΩ resolution, 1.9999 mΩ to 1.9999 kΩ ranges, ±(0.25 % of reading + 0.01 % FS); mains or NiMH battery powered, 320 x 240 display.
-
Enquire about CIE CIE-RTS-33
CIE CIE-RTS-33 Three Phase Relay Test Set
Three phase relay test set with variable current injection in 0-1 / 5 / 10 / 25 / 50 A ranges, 110 V phase-to-phase and 63.5 V phase-to-neutral voltages, fixed 30, 110 and 220 V DC outputs and phase angle control.
-
Enquire about Metrel MI 3252
Metrel MI 3252 MicroOhm 100A Low Resistance Ohmmeter
100 A micro-ohmmeter for circuit-breaker contacts, bus bars, weld joints and ground bonds: 1 nΩ resolution from 10.000 µΩ to 19.9999 Ω, ±0.25 % of reading; mains or 12 V battery, 1000-result memory.
-
Enquire about CIE CIE/7050
CIE CIE/7050 Transformer Oil Test Set 0-50kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about Metrel MI 3280
Metrel MI 3280 DT Analyser Digital Transformer Analyser
Portable transformer analyser for single and three phase transformers: turn ratio 0.8 to 8000, phase deviation, excitation current and winding resistance 1 mΩ to 999.9 Ω; Li-ion or mains, IP65 case.
-
Enquire about CIE CIE/7050 MOT
CIE CIE/7050 MOT Transformer Oil Test Set 0-50kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-50 kV, 500 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about Metrel MI 3281
Metrel MI 3281 WR Analyser Transformer Winding Resistance Analyser
Transformer winding resistance analyser with test currents from 10 mA to 20 A: 0.1 µΩ resolution, ±0.25 % accuracy, manual or automatic tap-changer test and demagnetisation; colour display, IP65 case.
-
Enquire about CIE CIE/7060
CIE CIE/7060 Transformer Oil Test Set 0-60kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7060 MOT
CIE CIE/7060 MOT Transformer Oil Test Set 0-60kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-60 kV, 600 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7070
CIE CIE/7070 Transformer Oil Test Set 0-70kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7070 MOT
CIE CIE/7070 MOT Transformer Oil Test Set 0-70kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-70 kV, 700 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7080
CIE CIE/7080 Transformer Oil Test Set 0-80kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7080 MOT
CIE CIE/7080 MOT Transformer Oil Test Set 0-80kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-80 kV, 800 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7100
CIE CIE/7100 Transformer Oil Test Set 0-100kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7100 MOT
CIE CIE/7100 MOT Transformer Oil Test Set 0-100kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-100 kV, 1000 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7120
CIE CIE/7120 Transformer Oil Test Set 0-120kV, Manual Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, manual operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE CIE/7120 MOT
CIE CIE/7120 MOT Transformer Oil Test Set 0-120kV, Motor Operated
Oil breakdown voltage (BDV) test set to IS 6792:1992 for transformer and switchgear oil: 0-120 kV, 1200 VA, cast resin HV transformer, motor operated version, brass electrodes with 2.5 / 4 mm gap and interlocked chamber.
-
Enquire about CIE MR-253A
CIE MR-253A Digital Micro-Ohm Meter, 4 Terminal
Bench micro-ohm meter for contact and low resistance by the 4-terminal method: eight ranges from 1999 μΩ (1 μΩ resolution, 2 A test current) to 19.99 kΩ, 3½ digit LED display and ±0.5% rdg ±2 digits.