Phoenix Contact UNO2-PS/1AC/24DC/60W/PT UNO2-PS/1AC/24DC/60W/PT Power Supply
- Brand
- Phoenix Contact
- Model number
- UNO2-PS/1AC/24DC/60W/PT
- Category
- DIN-Rail Power Supplies
Primary-switched power supply unit UNO POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A, adjustable from 24 V DC ... 29 V DC
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Output 24 V DC, 2.5 A (60 W)
- Input 100 V AC ... 277 V AC
- Efficiency typ. 92 % (120 V AC)
- Width 30 mm
- Operating temperature -25 °C ... 70 °C (> 55°C, derating POUT - 2.5%/K)
- Degree of protection IP20
Specifications
| Supply system configuration | TN, TT, IT (PE) |
|---|---|
| Nominal input voltage range | 100 V AC ... 277 V AC |
| Input voltage range | 100 V AC ... 277 V AC -15 % ... +10 %; 110 V AC ... 277 V AC ±10 % (UL) |
| Derating | < 100 V AC (1 %/V) |
| Typical national grid voltage | 120 V AC; 230 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | typ. 35 A (at 25 °C) |
| Inrush current integral (I2t) | < 0.7 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
| Mains buffering time | typ. 19 ms (120 V AC); typ. 82 ms (230 V AC) |
| Current consumption | 1.1 A (100 V AC); 0.6 A (277 V AC) |
| Protective circuit | Transient surge protection; Varistor |
| Switch-on time | typ. 1 s |
| Device mains fuse | 4 A internal (device protection), slow-blow |
| Recommended breaker for input protection | 6 A ... 20 A (Characteristic B, C, D, K or comparable) |
| Discharge current to PE | < 0.25 mA |
| Input voltage range | 110 V DC ... 250 V DC ±20 %; 125 V DC ... 250 V DC ±10 % (UL) |
|---|---|
| Derating | < 110 V DC (1 %/V) |
| Voltage type of supply voltage | DC |
| Current consumption | 0.6 A (110 V DC); 0.26 A (250 V DC) |
| Efficiency | typ. 92 % (120 V AC); typ. 93 % (230 V AC) |
|---|---|
| Nominal output voltage | 24 V DC |
| Setting range of the output voltage (USet) | 24 V DC ... 29 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) | 2.5 A |
| Output current range | 2.1 A ... 2.5 A |
| Short-circuit-proof | yes |
| Crest factor | typ. 3.44 (120 V AC); typ. 4.13 (230 V AC) |
| Output power (PN) | 60 W |
| Connection in parallel | yes, for increasing power and redundancy with diode |
| Connection in series | yes, for increased output voltage |
| Feedback voltage resistance | ≤ 35 V DC |
| Protection against overvoltage at the output (OVP) | ≤ 35 V DC |
| Residual ripple | typ. 40 mVPP (with nominal values) |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %); < 3 % (change in load, dynamic 10 % ... 90 %); < 0.1 % (change in input voltage ±10 %) |
| Rise time | < 1 s (UOut = 10 % ... 90 %) |
| Minimum no-load power dissipation | < 0.21 W (120 V AC) |
| Maximum no-load power dissipation | < 0.21 W (230 V AC) |
| Minimum nominal load power dissipation | < 4.9 W (120 V AC) |
| Power loss nominal load max. | < 4.5 W (230 V AC) |
| Integrated fuse protection | no |
| Fuse protection (secondary side) | electronic |
| Position | 1.x |
|---|---|
| Identification | 1.1 (L), 1.2 (N) |
| Connection method | Push-in connection |
|---|---|
| rigid (Terminal block) | 0.75 mm² ... 4 mm² (Push-in connection) |
| rigid (recommended) | 1 mm² |
| flexible (Klemme) | 0.2 mm² ... 4 mm² |
| flexible (empfohlen) | 1 mm² |
| flexible with ferrule without plastic sleeve (Terminal block) | 0.2 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve (recommended) | 1 mm² |
| flexible with ferrule with plastic sleeve (Terminal block) | 0.2 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve (recommended) | 1 mm² |
| AWG (Terminal block) | 24 ... 12 |
| AWG (recommended) | 17 |
| Stripping length | 10 mm |
| Screwdriver blade | 0.6 x 3.5 mm |
| rigid (AWG) (Terminal block) | 24 ... 12 |
| rigid (AWG) (recommended) | 17 |
| rigid | 0.2 mm² ... 4 mm² |
| flexible | 0.2 mm² ... 4 mm² |
| flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| AWG | 24 ... 14 (Cu) |
| Position | 2.x |
|---|---|
| Identification | 2.1, 2.2 (+), 2.3, 2.4 (-) |
| Types of signaling | LED DC OK - signal state operation (UN = 24 V DC, IOut = IN) |
|---|---|
| Function | Visual operating state display |
| Color | green |
| LED off | Supply voltage input AC not present (Off) |
| LED on (green), DC OK | UOUT > 0,9 x UN (On (green), DC OK) |
| Number of phases | 1 |
|---|---|
| Insulation voltage input/output | 4 kV AC (type test); 3.75 kV AC (routine test) |
| Product type | Power supply |
|---|---|
| Product family | UNO POWER |
| MTBF (IEC 61709, SN 29500) | > 2157000 h (25 °C); > 1217000 h (40 °C); > 625000 h (55 °C) |
| Protection class | II |
|---|---|
| Overvoltage category (EN 61010-1) | II (≤ 5000 m) |
| Overvoltage category (EN 62477-1) | III (≤ 2000 m) |
| Overvoltage category (EN 61558-2-16) | III ( 2000 m, UIN - 100 V AC ... 250 V AC, 110 V DC ... 250 V DC); II (≤ 4000 m) |
| Overvoltage category (EN 62368-1) | II (≤ 5000 m) |
| Degree of pollution | 2 |
| Width | 30 mm |
|---|---|
| Height | 90 mm |
| Depth | 90 mm |
| Depth (Device depth (DIN rail mounting)) | 84 mm (Device depth (DIN rail mounting)) |
| Installation distance right/left | 0 mm / 0 mm |
|---|---|
| Installation distance top/bottom | 30 mm / 30 mm |
| Mounting type | DIN rail mounting |
|---|---|
| Assembly note | alignable - horizontally - 0 mm, vertically - 30 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| With protective coating | no |
| Flammability rating according to UL 94 | V0 (Housing, terminal blocks) |
|---|---|
| Housing material | Plastic; PC |
| Type of housing | Polycarbonate |
| Foot latch material | PBT (polybutylene terephthalate) |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 55°C, derating POUT - 2.5%/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude (Maximum) | ≤ 5000 m |
| Maximum altitude (Output power derating) | > 2000 m (Derating POUT - 10 %/1000 m) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Vibration (operation) | 10 Hz ... 56.9 Hz, amplitude ±0.35 mm (IEC 60068-2-6); 59.6 Hz ... 150 Hz, 5g, 20 cycles |
| Temp code | T4 (-25 ... +70 °C; > 55 °C, Derating POUT - 2,5 %/K) |
| Standard designation | Safety of power supply units up to 1100 V (insulation distances) |
|---|---|
| Standards/specifications | DIN EN 61558-2-16 |
| Standard designation | Electrical safety; Safety for equipment for measurement, control, and laboratory use |
|---|---|
| Standards/specifications | IEC 61010-2-201 (SELV); IEC 61010-1 |
| Standard designation | Protective extra-low voltage |
|---|---|
| Standards/specifications | IEC 61010-1 (SELV); IEC 61010-2-201 (PELV) |
| Standard designation | Safe isolation |
|---|---|
| Standards/specifications | IEC 61558-2-16; IEC 61010-2-201 |
| Standard designation | Limitation of harmonic line currents |
|---|---|
| Standards/specifications | EN 61000-3-2 |
| Standard designation | Mains variation/undervoltage |
|---|---|
| Standards/specifications | SEMI F47 - 0706 (200 V AC) |
| Identification | UL 1310 Class 2 Power Units; UL/C-UL Listed UL 61010-1; UL/C-UL Listed UL 61010-2-201 |
|---|
| Identification | PROCESS CONTROL EQUIPEMENT FOR HAZARDOUS LOCATIONS; (EN) This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations, or non-hazardous locations only.(FR) Cet appareil convient uniquement pour une utilisation en atmosphères explosibles de classe I, division 2, groupes A, B, C et D ou en atmosphères non explosibles.; (EN) WARNING - Explosion Hazard - Do not connect or disconnect equipment unless power has been switched off or the area is known to be |
|---|
| Identification | CB scheme (IEC 61010-1, IEC 61010-2-201) |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
Model numbers in this series (1)
Send us the complete code you need and we will quote it.
1399933
About the UNO2-PS/1AC/24DC/60W/PT
UNO POWER compact power supply for DIN-rail mounting, for price-oriented applications. Primary-switched power supply unit UNO POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A, adjustable from 24 V DC ... 29 V DC Order no. 1399933.