Key features

  • Output 12 V DC, 5 A (60 W)
  • Input 100 V AC ... 277 V AC
  • Efficiency typ. 90.5 % (120 V AC)
  • Width 30 mm
  • Operating temperature -25 °C ... 70 °C (> 55°C, derating POUT - 2.5%/K)
  • Degree of protection IP20

Specifications

Input data - AC operation
Supply system configurationTN, TT, IT (PE)
Nominal input voltage range100 V AC ... 277 V AC
Input voltage range100 V AC ... 277 V AC -15 % ... +10 %; 110 V AC ... 277 V AC ±10 % (UL)
Derating< 100 V AC (1 %/V)
Typical national grid voltage120 V AC; 230 V AC
Voltage type of supply voltageAC
Inrush currenttyp. 35 A (at 25 °C)
Inrush current integral (I2t)< 0.8 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 19 ms (120 V AC); typ. 81 ms (230 V AC)
Current consumption1.1 A (100 V AC); 0.47 A (277 V AC)
Protective circuitTransient surge protection; Varistor
Switch-on timetyp. 1 s
Device mains fuse4 A internal (device protection), slow-blow
Recommended breaker for input protection6 A ... 20 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 0.25 mA
Input data - DC operation
Input voltage range110 V DC ... 250 V DC ±20 %; 125 V DC ... 250 V DC ±10 % (UL)
Derating< 110 V DC (1 %/V)
Voltage type of supply voltageDC
Current consumption0.6 A (110 V DC); 0.26 A (250 V DC)
Output data
Efficiencytyp. 90.5 % (120 V AC); typ. 91.4 % (230 V AC)
Nominal output voltage12 V DC
Setting range of the output voltage (USet)10 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN)5 A
Output current range3.3 A ... 5 A
Short-circuit-proofyes
Crest factortyp. 3.33 (120 V AC); typ. 3.88 (230 V AC)
Output power (PN)60 W
Connection in parallelyes, for increasing power and redundancy with diode
Connection in seriesyes, for increased output voltage
Feedback voltage resistance≤ 25 V DC
Protection against overvoltage at the output (OVP)≤ 25 V DC
Residual rippletyp. 80 mVPP (with nominal values)
Control deviation< 1 % (change in load, static 10 % ... 90 %); < 3 % (change in load, dynamic 10 % ... 90 %); < 0.1 % (change in input voltage ±10 %)
Rise time< 1 s (UOut = 10 % ... 90 %)
Minimum no-load power dissipation< 0.11 W (120 V AC)
Maximum no-load power dissipation< 0.21 W (230 V AC)
Minimum nominal load power dissipation< 6.3 W (120 V AC)
Power loss nominal load max.< 5.7 W (230 V AC)
Integrated fuse protectionno
Fuse protection (secondary side)electronic
Connection data - Input
Position1.x
Identification1.1 (L), 1.2 (N)
Connection data - Conductor connection
Connection methodPush-in connection
rigid (Terminal block)0.75 mm² ... 4 mm² (Push-in connection)
rigid (recommended)1 mm² (Push-in connection); 1 mm²
flexible (Klemme)0.2 mm² ... 4 mm²
flexible (empfohlen)1 mm²
flexible with ferrule without plastic sleeve (Terminal block)0.2 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve (recommended)1 mm²
flexible with ferrule with plastic sleeve (Terminal block)0.2 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve (recommended)1 mm²
AWG (Terminal block)24 ... 12
AWG (recommended)17
Stripping length10 mm
Screwdriver blade0.6 x 3.5 mm
rigid (AWG) (Terminal block)24 ... 12
rigid (AWG) (recommended)17
rigid0.2 mm² ... 4 mm²
flexible0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve0.25 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.25 mm² ... 2.5 mm²
AWG24 ... 14 (Cu)
Connection data - Output
Position2.x
Identification2.1, 2.2 (+), 2.3, 2.4 (-)
Signaling - LED signaling
Types of signalingLED DC OK - signal state operation (UN = 12 V DC, IOut = IN)
FunctionVisual operating state display
Colorgreen
LED offSupply voltage input AC not present (Off)
LED on (green), DC OKUOUT > 0,9 x UN (On (green), DC OK)
Electrical properties
Number of phases1
Insulation voltage input/output4 kV AC (type test); 3.75 kV AC (routine test)
Product properties
Product typePower supply
Product familyUNO POWER
MTBF (IEC 61709, SN 29500)> 1903000 h (25 °C); > 1041000 h (40 °C); > 517000 h (55 °C)
Product properties - Insulation characteristics
Protection classII
Overvoltage category (EN 61010-1)II (≤ 5000 m)
Overvoltage category (EN 62477-1)III (≤ 2000 m)
Overvoltage category (EN 61558-2-16)III ( 2000 m, UIN - 100 V AC ... 250 V AC, 110 V DC ... 250 V DC); II (≤ 4000 m)
Overvoltage category (EN 62368-1)II (≤ 5000 m)
Degree of pollution2
Dimensions - Item dimensions
Width30 mm
Height90 mm
Depth90 mm
Depth (Device depth (DIN rail mounting))84 mm (Device depth (DIN rail mounting))
Mounting
Mounting typeDIN rail mounting
Assembly notealignable - horizontally - 0 mm, vertically - 30 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno
Material specifications
Flammability rating according to UL 94V0 (Housing, terminal blocks)
Housing materialPlastic; PC
Type of housingPolycarbonate
Foot latch materialPBT (polybutylene terephthalate)
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55°C, derating POUT - 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m
Maximum altitude (Output power derating)> 2000 m (Derating POUT - 10 %/1000 m)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation)10 Hz ... 56.9 Hz, amplitude ±0.35 mm (IEC 60068-2-6); 59.6 Hz ... 150 Hz, 5g, 20 cycles
Temp codeT4 (-25 ... +70 °C; > 55 °C, Derating POUT - 2,5 %/K)
Standards and regulations - Safety of power supply units up to 1100 V (insulatio
Standard designationSafety of power supply units up to 1100 V (insulation distances)
Standards/specificationsDIN EN 61558-2-16
Standards and regulations - Electrical safety
Standard designationElectrical safety; Safety for equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-2-201 (SELV); IEC 61010-1
Standards and regulations - Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV); IEC 61010-2-201 (PELV)
Standards and regulations - Safe isolation
Standard designationSafe isolation
Standards/specificationsIEC 61558-2-16; IEC 61010-2-201
Standards and regulations - Limitation of harmonic line currents
Standard designationLimitation of harmonic line currents
Standards/specificationsEN 61000-3-2
Standards and regulations - Mains variation/undervoltage
Standard designationMains variation/undervoltage
Standards/specificationsSEMI F47 - 0706 (200 V AC)
Approvals - UL
IdentificationUL 1310 Class 2 Power Units; UL/C-UL Listed UL 61010-1; UL/C-UL Listed UL 61010-2-201
Approvals - ANSI/UL 121201
IdentificationPROCESS CONTROL EQUIPEMENT FOR HAZARDOUS LOCATIONS; (EN)  This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations, or non-hazardous locations only.(FR)  Cet appareil convient uniquement pour une utilisation en atmosphères explosibles de classe I, division 2, groupes A, B, C et D ou en atmosphères non explosibles.; (EN)  WARNING - Explosion Hazard - Do not connect or disconnect equipment unless power has been switched off or the area is known to be
Approvals - SIQ
IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 1399936

About the UNO2-PS/1AC/12DC/60W/PT

UNO POWER compact power supply for DIN-rail mounting, for price-oriented applications. Primary-switched power supply unit UNO POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 12 V DC / 5 A, adjustable from 10 V DC ... 18 V DC Order no. 1399936.