Phoenix Contact TRIO-PS-2G/3AC/72DC/14 TRIO-PS-2G/3AC/72DC/14 Power Supply

Model number
TRIO-PS-2G/3AC/72DC/14

Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 72 V DC/14 A, dynamic boost, tool-free fast connection technology for rigid and flexible conductors with ferrule

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Phoenix Contact TRIO-PS-2G/3AC/72DC/14 TRIO-PS-2G/3AC/72DC/14 Power Supply.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Output 72 V DC ±1 %, 14 A
  • Input 3x 400 V AC ... 500 V AC
  • Efficiency > 94.6 % (400 V AC)
  • Width 110 mm
  • Operating temperature -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
  • Degree of protection IP20

Specifications

Input data - AC operation
Network typeStar network
Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 400 V AC ... 500 V AC -20 % ... +15 %
Typical national grid voltage3x 400 V AC; 3x 480 V AC
Voltage type of supply voltageAC
Inrush current≤ 30 A (typical)
Inrush current integral (I2t)< 1.1 A2s
Inrush current limitation35 A (after 1 ms)
AC frequency range50 Hz ... 60 Hz
Frequency range (fN)50 Hz ... 60 Hz ±5 Hz
Mains buffering time> 10 ms (400 V AC); > 20 ms (480 V AC)
Current consumption3x 1.9 A (400 V AC); 3x 1.7 A (500 V AC)
Nominal power consumption1335.1 VA
Protective circuitTransient surge protection; Varistor
Power factor0.77
Typical response time< 1 s
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection10 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 3.5 mA; < 2.5 mA (550 V AC, 60 Hz)
Output data
Efficiency> 94.6 % (400 V AC); > 94.3 % (480 V AC)
Output characteristicU/I with dynamic load reserve
Nominal output voltage72 V DC ±1 %
Setting range of the output voltage (USet)70 V DC ... 85 V DC (> 72 V DC, constant capacity restricted)
Nominal output current (IN)14 A
Dynamic Boost (IDyn.Boost)21 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance< 105 V DC
Protection against overvoltage at the output (OVP)≤ 105 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %); < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz); < 0.1 % (change in input voltage ±10 %)
Residual ripple≤ 300 mVPP
Short-circuit-proofyes
No-load proofyes
Output power1008 W; 1512 W (5 s)
Maximum no-load power dissipation< 7 W (400 V AC)
Power loss nominal load max.< 58 W (400 V AC)
Short-circuit current< 23.5 A DC (permanent)
Rise time≤ 2 ms (UOUT (10 % ... 90 %))
Connection in parallelyes
Connection in seriesyes
Fuse protection (secondary side)electronic
Output data - Signal - DC OK
Continuous load current100 mA
Output data - Signal relay 13/14
Defaultclosed
Digital30 V AC 30 V DC 100 mA
Connection data - Input
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.4 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.12
Stripping length10 mm
Connection data - Output
Connection methodPush-in connection
Conductor cross-section, rigid min.0.75 mm²
Conductor cross-section, rigid max.16 mm²
Conductor cross-section flexible min.0.75 mm²
Conductor cross-section flexible max.16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.75 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.10 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.16 mm²
Conductor cross-section AWG min.20
Conductor cross-section AWG max.4
Stripping length18 mm
Connection data - Signal
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.0.75 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.1 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.18
Stripping length8 mm
Signaling
Types of signalingLED; Floating signal contact
Signaling - Signal output - LED status indicator
Signalization designationDC OK
Status displayLED
Colorgreen
DC OKUOUT > 0.95 x UN (UN = 72 V DC)
13/14UOUT > 0.95 x UN (UN = 72 V DC)
Electrical properties
Number of phases3
Insulation voltage input/output4.2 kV AC (type test); 2 kV AC (routine test)
Product properties
Product typePower supply
Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1730000 h (25 °C); > 1051000 h (40 °C); > 510000 h (60 °C)
Product properties - Insulation characteristics
Protection classI (in closed control cabinet)
Overvoltage category (EN 61010-1)II (≤ 2000 m)
Degree of pollution2
Dimensions
Width110 mm
Height130 mm
Depth160 mm
Dimensions - Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm
Mounting
Mounting typeDIN rail mounting
Assembly notealignable - horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialPlastic
Type of housingAluminum (AlMg3)
Hood versionPolycarbonate
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating - 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock11 ms, 15 g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6); 15 Hz ... 150 Hz, 0.7g, 90 min.
Standards and regulations
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 61010-2-201
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Approvals
UL approvalsUL/C-UL Listed UL 61010-1
Approvals - Conformity/Approvals
SIL in accordance with IEC 615080

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 1076188

About the TRIO-PS-2G/3AC/72DC/14

TRIO POWER power supply for DIN-rail mounting with standard functionality. Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 72 V DC/14 A, dynamic boost, tool-free fast connection technology for rigid and flexible conductors with ferrule Order no. 1076188.