Phoenix Contact TRIO-PS-2G/3AC/24DC/40 TRIO-PS-2G/3AC/24DC/40 Power Supply
- Brand
- Phoenix Contact
- Model number
- TRIO-PS-2G/3AC/24DC/40
- Category
- DIN-Rail Power Supplies
Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Output 24 V DC ±1 %, 40 A
- Input 3x 400 V AC ... 500 V AC
- Efficiency typ. 92.6 % (400 V AC)
- Width 110 mm
- Operating temperature -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
- Degree of protection IP20
Specifications
| Network type | Star network |
|---|---|
| Nominal input voltage range | 3x 400 V AC ... 500 V AC |
| Input voltage range | 3x 400 V AC ... 500 V AC -20 % ... +15 % |
| Typical national grid voltage | 3x 400 V AC; 3x 480 V AC |
| Voltage type of supply voltage | AC |
| Inrush current integral (I2t) | ≤ 1.1 A2s |
| Inrush current limitation | 35 A (after 1 ms) |
| AC frequency range | 50 Hz ... 60 Hz |
| Frequency range (fN) | 50 Hz ... 60 Hz ±5 Hz |
| Mains buffering time | > 10 ms (400 V AC); > 20 ms (480 V AC) |
| Current consumption | 3x 1.9 A (400 V AC); 3x 1.7 A (500 V AC) |
| Nominal power consumption | 1335.1 VA |
| Protective circuit | Transient surge protection; Varistor |
| Power factor (UMin) | > 0.7 (400 V AC) |
| Power factor (UMax) | > 0.7 (480 V AC) |
| Typical response time | < 1 s |
| Input fuse | 6.3 A (internal (device protection)) |
| Recommended breaker for input protection | 10 A ... 16 A (Characteristics B, C, D, K) |
| Discharge current to PE | < 3.5 mA; < 2.5 mA (550 V AC, 60 Hz) |
| Efficiency | typ. 92.6 % (400 V AC); typ. 92.6 % (480 V AC) |
|---|---|
| Output characteristic | U/I with dynamic load reserve |
| Nominal output voltage | 24 V DC ±1 % |
| Setting range of the output voltage (USet) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) | 40 A |
| Dynamic Boost (IDyn.Boost) | 60 A (5 s) |
| Derating | > 60 °C ... 70 °C (2.5 %/K) |
| Feedback voltage resistance | < 35 V |
| Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %); < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz); < 0.1 % (change in input voltage ±10 %) |
| Residual ripple | ≤ 50 mVPP |
| Short-circuit-proof | yes |
| No-load proof | yes |
| Output power | 960 W; 1440 W (5 s) |
| Maximum no-load power dissipation | typ. 14 W (400 V AC); typ. 17 W (480 V AC) |
| Power loss nominal load max. | < 70 W (480 V AC); typ. 72 W (480 V AC) |
| Short-circuit current | < 48 A DC (permanent) |
| Rise time | ≤ 1 s (UOUT (10 % ... 90 %)) |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Continuous load current | 100 mA |
|---|
| Default | closed |
|---|---|
| Digital | 30 V AC 30 V DC 100 mA |
| Connection method | Push-in connection |
|---|---|
| Conductor cross-section, rigid min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 4 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section flexible max. | 2.5 mm² |
| Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² |
| Single conductor/terminal point, stranded, with ferrule, max. | 2.5 mm² |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section AWG max. | 12 |
| Stripping length | 10 mm |
| Connection method | Push-in connection |
|---|---|
| Conductor cross-section, rigid min. | 0.75 mm² |
| Conductor cross-section, rigid max. | 16 mm² |
| Conductor cross-section flexible min. | 0.75 mm² |
| Conductor cross-section flexible max. | 10 mm² |
| Single conductor/terminal point, stranded, with ferrule, min. | 0.75 mm² |
| Single conductor/terminal point, stranded, with ferrule, max. | 10 mm² |
| Conductor cross-section AWG min. | 20 |
| Conductor cross-section AWG max. | 4 |
| Stripping length | 18 mm |
| Connection method | Push-in connection |
|---|---|
| Conductor cross-section, rigid min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 1.5 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section flexible max. | 1.5 mm² |
| Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² |
| Single conductor/terminal point, stranded, with ferrule, max. | 1.5 mm² |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section AWG max. | 16 |
| Stripping length | 8 mm |
| Types of signaling | LED; Floating signal contact |
|---|
| Signalization designation | DC OK |
|---|---|
| Status display | LED |
| Color | green |
| DC OK | UOUT > 0.9 x UN (UN = 24 V DC) |
| 13/14 | UOUT > 0.9 x UN (UN = 24 V DC) |
| Number of phases | 3 |
|---|---|
| Insulation voltage input/output | 3 kV AC (type test); 1.5 kV AC (routine test) |
| Product type | Power supply |
|---|---|
| Product family | TRIO POWER |
| MTBF (IEC 61709, SN 29500) | > 1730000 h (25 °C); > 1051000 h (40 °C); > 510000 h (60 °C) |
| Protection class | I (in closed control cabinet) |
|---|---|
| Overvoltage category (EN 62368-1) | II (≤ 2000 m) |
| Degree of pollution | 2 |
| Width | 110 mm |
|---|---|
| Height | 130 mm |
| Depth | 160 mm |
| Installation distance right/left | 0 mm / 0 mm |
|---|---|
| Installation distance top/bottom | 50 mm / 50 mm |
| Mounting type | DIN rail mounting |
|---|---|
| Assembly note | alignable - horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| With protective coating | no |
| Flammability rating according to UL 94 (housing / terminal blocks) | V0 |
|---|---|
| Housing material | Metal |
| Type of housing | Aluminum (AlMg3) |
| Hood version | Polycarbonate |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, Derating - 10 %/1000 m) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock | 11 ms, 15 g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | DNV GL CG-0339 / Class B2 Hz - 100 Hz resonance search, 90 min. in resonance,2 Hz - 13.2 Hz, ±1 mm amplitude,13.2 Hz - 100 Hz, 0.7g acceleration |
| Rail applications | EN 50121-4 |
|---|---|
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| Standard - Electrical safety | IEC 62368-1 (SELV) |
| Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard - Safety of power supply units up to 1100 V (insulation distances) | DIN EN 61558-2-16 |
| UL approvals | UL Listed UL 508; UL/C-UL Recognized UL 60950-1 |
|---|
| SIL in accordance with IEC 61508 | 0 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
Model numbers in this series (1)
Send us the complete code you need and we will quote it.
2903156
About the TRIO-PS-2G/3AC/24DC/40
TRIO POWER power supply for DIN-rail mounting with standard functionality. Primary-switched TRIO power supply for DIN rail mounting, input: 3-phase, output: 24 V DC/40 A, dynamic boost, tool-free fast connection technology for solid and stranded conductors with ferrule Order no. 2903156.