Key features

  • Output 24 V DC ±1 %, 5 A
  • Input 100 V AC ... 240 V AC
  • Efficiency > 90 % (for 230 V AC and nominal values)
  • Width 35 mm
  • Operating temperature -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
  • Degree of protection IP20

Specifications

Input data - AC operation
Network typeStar network
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Input voltage range AC85 V AC ... 264 V AC
Electric strength, max.≤ 300 V AC 15 s
Typical national grid voltage120 V AC; 230 V AC
Voltage type of supply voltageAC
Inrush current≤ 16 A (typical)
Inrush current integral (I2t)< 0.6 A2s
Inrush current limitationtyp. 16 A (after 1 ms)
AC frequency range50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 20 ms (120 V AC); typ. 100 ms (230 V AC)
Current consumption2.2 A (100 V AC); 1.9 A (120 V AC); 1.1 A (230 V AC); 1.1 A (240 V AC)
Nominal power consumption272 VA
Protective circuitTransient surge protection; Varistor
Power factor0.5
Typical response time< 1 s
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 0.25 mA
Input data - DC operation
Nominal input voltage range110 V DC ... 250 V DC
Input voltage range99 V DC ... 275 V DC
Switch-on voltage≥ 88 V DC
Shut-down voltage< 60 V DC
Voltage type of supply voltageDC
Mains buffering time> 100 ms (230 V AC)
Current consumption1.4 A (110 V DC); 0.6 A (250 V DC)
Output data
Efficiency> 90 % (for 230 V AC and nominal values)
Output characteristicU/I with dynamic load reserve
Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)5 A
Dynamic Boost (IDyn.Boost)7.5 A (5 s)
Derating> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %); < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz); < 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP (with nominal values)
Output power120 W; 180 W (5 s)
Maximum no-load power dissipation< 1 W
Power loss nominal load max.< 16 W
Rise time≤ 12 ms (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesyes
Output data - Signal - DC OK
Maximum switching voltage30 V AC/DC
Continuous load current100 mA
Connection data - Input
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.4 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.2.5 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.12
Stripping length10 mm
Connection data - Output
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.4 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.2.5 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.12
Stripping length8 mm
Connection data - Signal
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.1.5 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.1.5 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.16
Stripping length8 mm
Signaling
Types of signalingLED; Floating signal contact
Signaling - Signal output - LED status indicator
Signalization designationDC OK
Status display“DC OK” LED
Colorgreen
Electrical properties
Number of phases1
Insulation voltage input/output3 kV AC (type test); 1.5 kV AC (routine test)
Product properties
Product typePower supply
Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 3380000 h (25 °C); > 1970000 h (40 °C); > 900000 h (60 °C)
Product properties - Insulation characteristics
Protection classII (in closed control cabinet)
Overvoltage category (EN 62368-1)II (≤ 2000 m)
Degree of pollution2
Dimensions
Width35 mm
Height130 mm
Depth115 mm
Dimensions - Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm
Mounting
Mounting typeDIN rail mounting
Assembly notealignable - horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialPlastic
Type of housingPolycarbonate
Hood versionPolycarbonate
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, Derating - 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6); 15 Hz ... 150 Hz, 4g, 90 min.
Standards and regulations
Rail applicationsEN 50121-4
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Electrical safetyIEC 62368-1 (SELV)
Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standards and regulations - Fire protection in rail vehicles
Standard designationFire protection in rail vehicles
Standards/specificationsEN 45545-2 (HL3)
Approvals
UL approvalsUL Listed UL 508; UL/C-UL Recognized UL 60950-1; UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Approvals - Conformity/Approvals
SIL in accordance with IEC 615080

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 2903148

About the TRIO-PS-2G/1AC/24DC/5

TRIO POWER power supply for DIN-rail mounting with standard functionality. Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: 1-phase, output: 24 V DC/5 A Order no. 2903148.