Phoenix Contact TRIO-PS-2G/1500DC/24DC/8 TRIO-PS-2G/1500DC/24DC/8 DC/DC Converter

Model number
TRIO-PS-2G/1500DC/24DC/8

Primary-switched TRIO POWER DC/DC converter with Push-in connection for DIN rail mounting, input: 1,500 V DC, output: 24 V DC / 8 A

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Phoenix Contact TRIO-PS-2G/1500DC/24DC/8 TRIO-PS-2G/1500DC/24DC/8 DC/DC Converter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Output 24 V DC ±1 %, 8 A
  • Input 600 V DC ... 1500 V DC
  • Efficiency typ. 91.5 % (600 V DC)
  • Width 88.5 mm
  • Operating temperature -25 °C ... 70 °C (>60°C derating - 1.2%/K)
  • Degree of protection IP20

Specifications

Input data - DC operation
Nominal input voltage range600 V DC ... 1500 V DC
Input voltage range600 V DC ... 1500 V DC -15 % ... +10 %
Wide-range inputno
Input voltage range DC600 V DC ... 1500 V DC -15 % ... +10 %
Electric strength, max.≤ 1800 V DC 1 s
Typical national grid voltage1500 V DC; 600 V DC
Voltage type of supply voltageDC
Inrush current integral (I2t)typ. 0.15 A2s
Current consumptiontyp. 0.35 A (600 V DC); typ. 0.145 A (1500 V DC)
Recommended breaker for input protection1 A (gPV)
Recommended fuse for input protection1500 V DC
Output data
Efficiencytyp. 91.5 % (600 V DC); typ. 90.9 % (900 V DC); typ. 89 % (1500 V DC)
Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)8 A
Derating> 60 °C ... 70 °C (2.5 %/K)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % ... 90 %); < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz); < 0.1 % (change in input voltage ±10 %)
Residual ripple< 40 mVPP (Ripple); < 50 mVPP (Noise)
Short-circuit-proofyes
No-load proofyes
Output power192 W
Maximum no-load power dissipation< 9 W
Power loss nominal load max.< 24 W
Rise time≤ 30 ms (UOUT (10 % ... 90 %))
Connection in parallelyes, for redundancy and increased capacity
Connection in seriesno
Fuse protection (secondary side)electronic
Output data - Signal - DC OK
Continuous load current100 mA
Output data - Signal relay 13/14
Defaultclosed
Digital30 V AC 30 V DC 100 mA
Connection data - Input
Connection methodPush-in connection
Conductor cross-section, rigid min.1 mm²
Conductor cross-section, rigid max.4 mm²
Conductor cross-section flexible min.1 mm²
Conductor cross-section flexible max.2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.1 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.1 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.2.5 mm²
Conductor cross-section AWG min.18
Conductor cross-section AWG max.12
Stripping length10 mm
Connection data - Output
Connection methodPush-in connection
Conductor cross-section, rigid min.1 mm²
Conductor cross-section, rigid max.4 mm²
Conductor cross-section flexible min.1 mm²
Conductor cross-section flexible max.2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.1.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.1.5 mm²
Conductor cross-section AWG min.18
Conductor cross-section AWG max.12
Stripping length10 mm
Connection data - Signal
Connection methodPush-in connection
Conductor cross-section, rigid min.0.2 mm²
Conductor cross-section, rigid max.1.5 mm²
Conductor cross-section flexible min.0.2 mm²
Conductor cross-section flexible max.1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.1.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.1.5 mm²
Conductor cross-section AWG min.24
Conductor cross-section AWG max.16
Stripping length8 mm
Signaling
Types of signalingLED; Floating signal contact
Signaling - Signal output - LED status indicator
Signalization designationDC OK
Status display"DC OK" LED green
Note on status displayUOUT > 21.5 V - LED lights up
Colorgreen
DC OKUOUT > 0.9 x UN (UN = 24 V DC)
13/14UOUT > 0.9 x UN (UN = 24 V DC)
Electrical properties
Number of phases1
Insulation voltage input/output2.4 kV DC (type test); 1.6 kV DC (routine test)
Product properties
Product typeDC/DC converters
Product familyTRIO POWER
MTBF (IEC 61709, SN 29500)> 1500000 h (25 °C); > 900000 h (40 °C); > 400000 h (60 °C)
Product properties - Insulation characteristics
Protection classI
Overvoltage category (IEC 62109-1)II
Degree of pollution2
Dimensions
Width88.5 mm
Height130 mm
Depth160 mm
Dimensions - Installation dimensions
Installation distance right/left0 mm / 0 mm (≤ 40°C)
Installation distance right/left (active)10 mm / 10 mm (≤ 70 °C)
Installation distance top/bottom50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (active)50 mm / 50 mm (≤ 70 °C)
Mounting
Mounting typeDIN rail mounting
Assembly notealignable - horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialMetal
Type of housingAluminum (AlMg3)
Hood versionPolycarbonate
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (>60°C derating - 1.2%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating - 10 %/1000 m)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6); 15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulations
Standard - Electrical safetyEN 62109-1-2011
Standard – Safety extra-low voltageIEC 62109-1-2011 (SELV)
Standard - Safe isolationDIN VDE 0100-410
Approvals
UL approvalsUL 62109-1-2014

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 1075240

About the TRIO-PS-2G/1500DC/24DC/8

TRIO POWER power supply for DIN-rail mounting with standard functionality. Primary-switched TRIO POWER DC/DC converter with Push-in connection for DIN rail mounting, input: 1,500 V DC, output: 24 V DC / 8 A Order no. 1075240.