Phoenix Contact STEP3-PS/1AC/KNX/640/LPT STEP3-PS/1AC/KNX/640/LPT Bus Power Supply
- Brand
- Phoenix Contact
- Model number
- STEP3-PS/1AC/KNX/640/LPT
- Category
- DIN-Rail Power Supplies
Primary-switched bus power supply STEP POWER, Lever Push-in connection, DIN rail or direct mounting, input: 1-phase, output: 30 V DC / 640 mA
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Output 30 V DC, 640 mA (IBUS + IAUX) (19.2 W)
- Efficiency > 86 % (120 V AC)
- Width 54 mm
- Operating temperature -10 °C ... 70 °C (Derating > 45 °C - 2 %/K)
- Degree of protection IP20
Specifications
| Supply system configuration | TN, TT, IT (PE) |
|---|---|
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Typical national grid voltage | 120 V AC; 230 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | typ. 35 A (25 °C) |
| Inrush current integral (I2t) | typ. 1.3 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
| Mains buffering time | typ. 100 ms (100 V AC); typ. 100 ms (230 V AC) |
| Current consumption | 0.41 A (100 V AC); 0.22 A (240 V AC) |
| Protective circuit | Transient surge protection; Varistor |
| Switch-on time | typ. 2 s |
| Device mains fuse | 4 A internal (device protection), slow-blow |
| Recommended breaker for input protection | 6 A ... 20 A (Characteristics B, C, D, K) |
| Discharge current to PE | < 3.5 mA |
| Input voltage range | 100 V DC ... 250 V DC -10 % ... +10 % |
|---|---|
| Voltage type of supply voltage | DC |
| Current consumption | 0.22 A (100 V DC); 0.09 A (250 V DC) |
| Efficiency | > 86 % (120 V AC); > 86 % (230 V AC) |
|---|---|
| Nominal output voltage | 30 V DC |
| Nominal output current (IN) | 640 mA (IBUS + IAUX) |
| Short-circuit-proof | yes |
| Derating | > 45 °C ... 70 °C (2 % / K) |
| Crest factor | typ. 3.4; typ. 4.08 |
| Output power (PN) | 19.2 W |
| Connection in parallel | yes, 2; yes, for increased efficiency and redundancy |
| Connection in series | no |
| Feedback voltage resistance | 35 V DC |
| Protection against overvoltage at the output (OVP) | 35 V DC |
| Residual ripple | typ. 100 mVPP |
| Control deviation | < 0.5 % (Static load change 10 % ... 90 %); < 3 % (Dynamic load change 10 % ... 90 %, (10 Hz)); < 0.1 % (change in input voltage ±10 %) |
| Rise time | typ. 100 ms (UOut = 10 % ... 90 %); typ. 100 ms |
| Minimum no-load power dissipation | < 0.25 W (120 V AC) |
| Maximum no-load power dissipation | < 0.31 W (230 V AC) |
| Minimum nominal load power dissipation | 3.1 W (120 V AC) |
| Power loss nominal load max. | 3.3 W (230 V AC) |
| Integrated fuse protection | no |
| Position | 1.x |
|---|
| Position marking | 1.1 (), 1.2 (N), 1.3 (L); 2.1 (BUS +), 2.2 (BUS -), 2.3 (AUX +), 2.4 (AUX -) |
|---|
| Connection method | Lever Push-in connection; Push-in connection |
|---|---|
| rigid (Terminal block) | 0.2 mm² ... 4 mm²; 0.34 mm² ... 0.5 mm² |
| rigid (recommended) | 1.5 mm² (recommended); 0.5 mm² (recommended) |
| flexible (Klemme) | 0.2 mm² ... 4 mm² |
| flexible (empfohlen) | 1.5 mm² (recommended) |
| flexible with ferrule without plastic sleeve (Terminal block) | 0.2 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve (recommended) | 1.5 mm² (recommended) |
| flexible with ferrule with plastic sleeve (Terminal block) | 0.2 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve (recommended) | 1.5 mm² (recommended) |
| rigid (AWG) (Terminal block) | 24 ... 12 (Cu); 22 ... 20 (Cu) |
| rigid (AWG) (recommended) | 16 (recommended); 20 (recommended) |
| Stripping length (starr/flexibel) | 10 mm (solid) |
| Stripping length (Aderendhülse) | 10 mm (Ferrule) |
| Stripping length | 5 mm ... 6 mm (solid) |
| Position | 2.x |
|---|
| Types of signaling | LED DC OK AUX; Display DC OK BUS; Display bar graph; Display temperature LED |
|---|---|
| Function | Visual operating state display |
| Color | green; red, yellow, green (multicolor LED); red, yellow, green; red, green |
| LED off | < 24 V DC (Off) |
| LED on (green), DC OK | > 24 V DC (lit); 28 V DC UOUT 31 V DC (LED lights up green) |
| Number of phases | 1 |
|---|---|
| Insulation voltage input/output | 4 kV AC (type test); 3.75 kV AC (routine test) |
| Product type | Bus power supply |
|---|---|
| Product family | STEP POWER |
| MTBF (IEC 61709, SN 29500) | > 1718000 h (25 °C); > 1052000 h (40 °C); > 750000 h (50 °C) |
| Protection class | I |
|---|---|
| Overvoltage category (EN 61010-2-201) | II (≤ 5000 m) |
| Overvoltage category (EN 62368-1) | II (≤ 5000 m) |
| Overvoltage category (EN 62477-1) | III (≤ 2000 m) |
| Overvoltage category (IEC 60664-1) | III (≤ 2000 m) |
| Overvoltage category (IEC 63044-3) | III (≤ 2000 m) |
| Overvoltage category (EN 61558-2-16) | II ( 3000 m) |
| Degree of pollution | 2 |
| Width | 54 mm |
|---|---|
| Height | 90 mm |
| Depth | 61 mm |
| Depth (Device depth (DIN rail mounting)) | 55 mm (Device depth (DIN rail mounting)) |
| Horizontal pitch | 3 HP (DIN 43880) |
| Installation distance right/left | 0 mm / 0 mm |
|---|---|
| Installation distance top/bottom | 30 mm / 30 mm |
| Mounting type | DIN rail or direct mounting |
|---|---|
| Assembly note | alignable - 0 mm horizontally, 30 mm vertically |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| With protective coating | no |
| Flammability rating according to UL 94 | V0 (Housing, terminal blocks, base latches) |
|---|---|
| Housing material | Plastic; PC |
| Foot latch material | Polyamid |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -10 °C ... 70 °C (Derating > 45 °C - 2 %/K) |
| Ambient temperature (storage/transport) | -30 °C ... 80 °C |
| Ambient temperature (start-up type tested) | -25 °C |
| Maximum altitude | ≤ 5000 m |
| Maximum altitude (Output power derating) | > 2000 m (Derating POUT - 10 %/1000 m) |
| Max. permissible relative humidity (operation) | ≤ 95 % (non-condensing) |
| Shock (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6); 15 Hz ... 150 Hz, 2.3g, 90 min. |
| Standard designation | Electrical safety; Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - General Requirements |
|---|---|
| Standards/specifications | IEC 61010-1 (SELV); IEC 63044-3 |
| Standard designation | Protective extra-low voltage |
|---|---|
| Standards/specifications | IEC 61010-1 (SELV); IEC 61010-2-201 (PELV) |
| Standard designation | Safe isolation |
|---|---|
| Standards/specifications | IEC 61558-2-16 |
| Standard designation | Safety requirements for electrical equipment for measurement, control, and laboratory use; Information technology - architecture for home electronic systems (KNX standard) |
|---|---|
| Standards/specifications | IEC 61010-1; IEC 14543-3 |
| Identification | UL/C-UL Listed UL 61010-1; UL/C-UL Listed UL 61010-2-201 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
Model numbers in this series (1)
Send us the complete code you need and we will quote it.
1477019
About the STEP3-PS/1AC/KNX/640/LPT
STEP POWER primary-switched power supply for DIN-rail mounting, slim and compact, for distribution boards and building automation. Primary-switched bus power supply STEP POWER, Lever Push-in connection, DIN rail or direct mounting, input: 1-phase, output: 30 V DC / 640 mA Order no. 1477019.