Phoenix Contact STEP3-PS/1AC/5DC/3/PT/USB-C STEP3-PS/1AC/5DC/3/PT/USB-C Power Supply
- Brand
- Phoenix Contact
- Model number
- STEP3-PS/1AC/5DC/3/PT/USB-C
- Category
- DIN-Rail Power Supplies
Primary-switched power supply unit STEP POWER, Push-in connection, DIN rail or direct mounting, Integrated cable groove with strain relief, input: 1-phase, output: 5 V DC / 3 A, USB-C up to 15 W
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Output 5 V DC, 3 A (15 W)
- Efficiency > 81.5 % (120 V AC)
- Width 18 mm
- Operating temperature -10 °C ... 70 °C (Derating - > 50 °C
- Degree of protection IP20
Specifications
| Supply system configuration | Star network (TN, TT, IT (PE)) |
|---|---|
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Typical national grid voltage | 120 V AC; 230 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | typ. 30 A (25 °C) |
| Inrush current integral (I2t) | typ. 0.14 A2s |
| Frequency range (fN) | 50 Hz ... 60 Hz ±10 % |
| Mains buffering time | typ. 18 ms (120 V AC); typ. 80 ms (230 V AC) |
| Current consumption | 0.3 A (100 V AC); 0.14 A (240 V AC) |
| Switch-on time | typ. 2 s |
| Device mains fuse | 1.25 A internal (device protection), slow-blow |
| Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
| Discharge current to PE | < 0.25 mA |
| Input voltage range | 110 V DC ... 250 V DC -20 % ... +10 % |
|---|---|
| Voltage type of supply voltage | DC |
| Current consumption | 0.17 A (110 V DC); 0.07 A (250 V DC) |
| Efficiency | > 81.5 % (120 V AC); > 82 % (230 V AC) |
|---|---|
| Nominal output voltage | 5 V DC |
| Nominal output current (IN) | 3 A |
| Short-circuit-proof | yes |
| No-load proof | yes |
| Derating | > 50 °C ... 70 °C (2 % / K) |
| Crest factor | typ. 3.3; typ. 4.2 |
| Output power (PN) | 15 W |
| Connection in parallel | yes, for increasing power and redundancy with diode |
| Connection in series | yes, for increased output voltage |
| Feedback voltage resistance | ≤ 10 V DC |
| Protection against overvoltage at the output (OVP) | < 10 V DC |
| Residual ripple | typ. 80 mVPP |
| Control deviation | < 1.5 % (Static load change 10 % ... 90 %); < 5 % (Dynamic load change 10 % ... 90 %, (10 Hz)); < 0.1 % (change in input voltage ±10 %) |
| Rise time | typ. 100 ms (UOut = 10 % ... 90 %) |
| Minimum no-load power dissipation | < 0.1 W (120 V AC) |
| Maximum no-load power dissipation | < 0.1 W (230 V AC) |
| Minimum nominal load power dissipation | < 3.4 W (120 V AC) |
| Power loss nominal load max. | < 3.2 W (230 V AC) |
| Integrated fuse protection | no |
| Position | 1.x |
|---|
| Position marking | 1.1, 1.2 (L), 1.3, 1.4 (N); 2.1 (USB-C) |
|---|
| Connection method | Push-in connection |
|---|---|
| rigid (Terminal block) | 0.2 mm² ... 2.5 mm² |
| rigid (recommended) | 1 mm² (recommended) |
| flexible (Klemme) | 0.2 mm² ... 2.5 mm² |
| flexible (empfohlen) | 1 mm² (recommended) |
| flexible with ferrule without plastic sleeve (Terminal block) | 0.5 mm² ... 1.5 mm² |
| flexible with ferrule without plastic sleeve (recommended) | 1 mm² (recommended) |
| flexible with ferrule with plastic sleeve (Terminal block) | 0.2 mm² ... 1 mm² |
| flexible with ferrule with plastic sleeve (recommended) | 1 mm² (recommended) |
| AWG (recommended) | 17 |
| AWG (Terminal block) | 24 ... 14 (Cu) |
| Stripping length (starr/flexibel) | 10 mm (rigid/flexible/ferrule without plastic sleeve) |
| Stripping length (Aderendhülse) | 13 mm (Ferrule with plastic sleeve) |
| Position | 2.x |
|---|
| Types of signaling | LED |
|---|---|
| Signal threshold | > 0.9 x UN (UN = 5 V DC) (LED lights up green); < 0.9 x UN (UN = 5 V DC) (LED off) |
| Number of phases | 1 |
|---|---|
| Insulation voltage input/output | 4 kV AC (type test); 3.75 kV AC (routine test) |
| Product type | Power supply |
|---|---|
| Product family | STEP POWER |
| MTBF (IEC 61709, SN 29500) | > 2370000 h (25 °C); > 1124000 h (40 °C); > 643000 h (50 °C) |
| Environmental protection directive | RoHS Directive 2011/65/EU; WEEE; Reach |
| Protection class | II (in closed control cabinet) |
|---|---|
| Overvoltage category (EN 61010-1) | II (≤ 4000 m) |
| Overvoltage category (EN 62477-1) | III (≤ 2000 m) |
| Degree of pollution | 2 |
| Width | 18 mm |
|---|---|
| Height | 90 mm |
| Depth | 61 mm |
| Depth (Device depth (DIN rail mounting)) | 55 mm (Device depth (DIN rail mounting)) |
| Horizontal pitch | 1 HP (DIN 43880) |
| Installation distance right/left | 0 mm / 0 mm |
|---|---|
| Installation distance top/bottom | 30 mm / 30 mm |
| Mounting type | DIN rail or direct mounting |
|---|---|
| Assembly note | alignable - 0 mm horizontally, 30 mm vertically |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| With protective coating | no |
| Flammability rating according to UL 94 | V0 (Housing, terminal blocks, base latches) |
|---|---|
| Housing material | Plastic; PC |
| Foot latch material | Polyamid |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -10 °C ... 70 °C (Derating - > 50 °C; 2 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -25 °C |
| Maximum altitude | ≤ 4000 m (> 2000 m, Derating - 10 %/1000 m) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock (operation) | 18 ms, 30g, per spatial direction (IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6); 15 Hz ... 150 Hz, 2.3g, 90 min. |
| Temp code | T4 (-10 ... +70 °C; > 50 °C, Derating - 2 %/K) |
| Standard designation | Safety extra-low voltage |
|---|---|
| Standards/specifications | IEC 61010-1 (SELV) |
| Standard designation | Protective extra-low voltage |
|---|---|
| Standards/specifications | IEC 61010-2-201 (PELV) |
| Standard designation | Safe isolation |
|---|---|
| Standards/specifications | IEC 61558-2-16 |
| Standard designation | Low-voltage power supplies, DC output |
|---|---|
| Standards/specifications | EN 61204-3 |
| Standard designation | Safety requirements for electrical equipment for measurement, control, and laboratory use |
|---|---|
| Standards/specifications | IEC 61010-1 |
| Standard designation | Safety of electrical devices for household use and similar purposes |
|---|---|
| Standards/specifications | DIN EN 60335-1 |
| Identification | UL/C-UL Listed UL 61010-1; UL/C-UL Listed UL 61010-2-201; UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location); UL 1310 Class 2 Power Units |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
Model numbers in this series (1)
Send us the complete code you need and we will quote it.
1335698
About the STEP3-PS/1AC/5DC/3/PT/USB-C
STEP POWER primary-switched power supply for DIN-rail mounting, slim and compact, for distribution boards and building automation. Primary-switched power supply unit STEP POWER, Push-in connection, DIN rail or direct mounting, Integrated cable groove with strain relief, input: 1-phase, output: 5 V DC / 3 A, USB-C up to 15 W Order no. 1335698.