Phoenix Contact STEP3-PS/1AC/24DC/0.63/PT STEP3-PS/1AC/24DC/0.63/PT Power Supply

Model number
STEP3-PS/1AC/24DC/0.63/PT

Primary-switched power supply unit STEP POWER, Push-in connection, DIN rail or direct mounting, input: 1-phase, output: 24 V DC / 0.63 A

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Phoenix Contact STEP3-PS/1AC/24DC/0.63/PT STEP3-PS/1AC/24DC/0.63/PT Power Supply.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Output 24 V DC, 0.63 A (15 W)
  • Efficiency > 86 % (120 V AC)
  • Width 18 mm
  • Operating temperature -10 °C ... 70 °C (Derating - > 50 °C
  • Degree of protection IP20

Specifications

Input data - AC operation
Supply system configurationStar network (TN, TT, IT (PE))
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Typical national grid voltage120 V AC; 230 V AC
Voltage type of supply voltageAC
Inrush currenttyp. 30 A (25 °C)
Inrush current integral (I2t)typ. 0.14 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 20 ms (120 V AC); typ. 90 ms (230 V AC)
Current consumption0.29 A (100 V AC); 0.16 A (240 V AC)
Switch-on timetyp. 2 s
Device mains fuse1.25 A internal (device protection), slow-blow
Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)
Discharge current to PE< 0.25 mA
Input data - DC operation
Input voltage range110 V DC ... 250 V DC -20 % ... +40 %
Voltage type of supply voltageDC
Current consumption0.16 A (110 V DC); 0.07 A (250 V DC)
Output data
Efficiency> 86 % (120 V AC); > 87 % (230 V AC)
Efficiency LevelVI
Nominal output voltage24 V DC
Nominal output current (IN)0.63 A
Short-circuit-proofyes
No-load proofyes
Derating> 50 °C ... 70 °C (2 % / K)
Crest factortyp. 3.24; typ. 4.17
Output power (PN)15 W
Connection in parallelyes, for increasing power and redundancy with diode
Connection in seriesyes, for increased output voltage
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)< 35 V DC
Residual rippletyp. 100 mVPP
Control deviation< 0.5 % (Static load change 10 % ... 90 %); < 4 % (Dynamic load change 10 % ... 90 %, (10 Hz)); < 0.1 % (change in input voltage ±10 %)
Rise timetyp. 100 ms (UOut = 10 % ... 90 %)
Minimum no-load power dissipation< 0.1 W (120 V AC)
Maximum no-load power dissipation< 0.1 W (230 V AC)
Minimum nominal load power dissipation< 2.5 W (120 V AC)
Power loss nominal load max.< 2.3 W (230 V AC)
Integrated fuse protectionno
Fuse protection (secondary side)electronic
Connection data - Input
Position1.x
Connection data - Connection technology - Positions
Position marking1.1, 1.2 (L), 1.3, 1.4 (N); 2.1, 2.2 (+), 2.3, 2.4 (-)
Connection data - Conductor connection
Connection methodPush-in connection
rigid (Terminal block)0.2 mm² ... 2.5 mm²
rigid (recommended)1 mm² (recommended)
flexible (Klemme)0.2 mm² ... 2.5 mm²
flexible (empfohlen)1 mm² (recommended)
flexible with ferrule without plastic sleeve (Terminal block)0.25 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve (recommended)1 mm² (recommended)
flexible with ferrule with plastic sleeve (Terminal block)0.25 mm² ... 1 mm²
flexible with ferrule with plastic sleeve (recommended)1 mm² (recommended)
AWG (recommended)17
AWG (Terminal block)24 ... 12 (Cu)
Stripping length (starr/flexibel)10 mm (rigid/flexible)
Stripping length (Aderendhülse)10 mm (Ferrule)
Connection data - Output
Position2.x
Signaling - LED signaling
Types of signalingLED
Signal threshold> 0,9 x UN (UN = 24 V DC) (LED lights up green); < 0,9 x UN (UN = 24 V DC) (LED off)
Electrical properties
Number of phases1
Insulation voltage input/output4 kV AC (type test); 3.75 kV AC (routine test)
Product properties
Product typePower supply
Product familySTEP POWER
MTBF (IEC 61709, SN 29500)> 3500000 h (25 °C); > 1800000 h (40 °C); > 1200000 h (50 °C)
Environmental protection directiveRoHS Directive 2011/65/EU; WEEE; Reach
Product properties - Insulation characteristics
Protection classII (in closed control cabinet)
Overvoltage category (EN 61010-1)II (≤ 4000 m)
Overvoltage category (EN 62477-1)III (≤ 2000 m)
Degree of pollution2
Dimensions - Item dimensions
Width18 mm
Height90 mm
Depth61 mm
Depth (Device depth (DIN rail mounting))55 mm (Device depth (DIN rail mounting))
Horizontal pitch1 HP (DIN 43880)
Dimensions - Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom30 mm / 30 mm
Mounting
Mounting typeDIN rail or direct mounting
Assembly notealignable - 0 mm horizontally, 30 mm vertically
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingno
Material specifications
Flammability rating according to UL 94V0 (Housing, terminal blocks, base latches)
Housing materialPlastic; PC
Foot latch materialPolyamid
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-10 °C ... 70 °C (Derating - > 50 °C; 2 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-25 °C
Maximum altitude≤ 4000 m (> 2000 m, Derating - 10 %/1000 m)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (IEC 60068-2-6); 15 Hz ... 150 Hz, 2.3g, 90 min.
Temp codeT4 (-10 ... +70 °C; > 50 °C, Derating - 2 %/K)
Standards and regulations - Safety extra-low voltage
Standard designationSafety extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)
Standards and regulations - Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-2-201 (PELV)
Standards and regulations - Safe isolation
Standard designationSafe isolation
Standards/specificationsIEC 61558-2-16
Standards and regulations - Low-voltage power supplies, DC output
Standard designationLow-voltage power supplies, DC output
Standards/specificationsEN 61204-3
Standards and regulations - Safety requirements for electrical equipment for mea
Standard designationSafety requirements for electrical equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1
Standards and regulations - Household and similar electrical appliances - Safety
Standard designationSafety of electrical devices for household use and similar purposes
Standards/specificationsDIN EN 60335-1
Standards and regulations - Electric vehicle conductive charging system - Part 2
Standard designationElectric vehicle conductive charging system - Part 21-2 - EMC requirements for off board electric vehicle charging systems
Standards/specificationsIEC 61851-21-2
NoteClass B
Approvals - UL
IdentificationUL 1310 Class 2 Power Units; UL/C-UL Listed UL 61010-1; UL/C-UL Listed UL 61010-2-201; UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 1088495

About the STEP3-PS/1AC/24DC/0.63/PT

STEP POWER primary-switched power supply for DIN-rail mounting, slim and compact, for distribution boards and building automation. Primary-switched power supply unit STEP POWER, Push-in connection, DIN rail or direct mounting, input: 1-phase, output: 24 V DC / 0.63 A Order no. 1088495.