Phoenix Contact STEP-PS/1AC/5DC/6.5 STEP-PS/1AC/5DC/6.5 Power Supply
- Brand
- Phoenix Contact
- Model number
- STEP-PS/1AC/5DC/6.5
- Category
- DIN-Rail Power Supplies
Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/6.5 A
Price and availability on request
We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.
Several models? Add each to your enquiry list and send them as one enquiry.
Key features
- Output 5 V DC, 6.5 A (-25 °C ... 55 °C)
- Input 100 V AC ... 240 V AC
- Efficiency > 80 % (for 230 V AC and nominal values)
- Width 72 mm
- Operating temperature -25 °C ... 70 °C (> 55° C derating - 2.5%/K)
- Degree of protection IP20
Specifications
| Nominal input voltage range | 100 V AC ... 240 V AC |
|---|---|
| Input voltage range | 85 V AC ... 264 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | < 15 A (typical) |
| Inrush current integral (I2t) | < 0.6 A2s |
| AC frequency range | 45 Hz ... 65 Hz |
| Frequency range DC | 0 Hz |
| Mains buffering time | typ. 25 ms (120 V AC); typ. 140 ms (230 V AC) |
| Current consumption | 0.5 A (120 V AC); 0.3 A (230 V AC) |
| Nominal power consumption | 72.1 VA |
| Protective circuit | Transient surge protection; Varistor |
| Power factor | 0.57 |
| Typical response time | < 0.5 s |
| Input fuse | 3.15 A (slow-blow, internal) |
| Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
| Input voltage range | 95 V DC ... 250 V DC |
|---|---|
| Voltage type of supply voltage | DC |
| Efficiency | > 80 % (for 230 V AC and nominal values) |
|---|---|
| Output characteristic | U/I |
| Nominal output voltage | 5 V DC |
| Setting range of the output voltage (USet) | 4 V DC ... 6.5 V DC (> 5 V DC, constant capacity restricted) |
| Output current Imax | 11.5 A |
| Nominal output current (IN) | 6.5 A (-25 °C ... 55 °C); 7.1 A (-25 °C ... 40 °C permanent) |
| Derating | 55 °C ... 70 °C (2.5 %/K) |
| Feedback voltage resistance | ≤ 10 V DC |
| Protection against overvoltage at the output (OVP) | < 10 V DC |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %); < 2 % (change in load, dynamic 10 % ... 90 %); < 0.1 % (change in input voltage ±10 %) |
| Residual ripple | < 50 mVPP (20 MHz) |
| Output power | 32.5 W |
| Peak switching voltages nominal load | < 40 mVPP (20 MHz) |
| Maximum no-load power dissipation | < 0.4 W |
| Power loss nominal load max. | < 8.1 W |
| Rise time | < 0.5 s (UOUT (10 % ... 90 %)) |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Fuse protection (secondary side) | electronic |
| Connection method | Screw connection |
|---|---|
| Conductor cross-section, rigid min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 2.5 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section flexible max. | 2.5 mm² |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section AWG max. | 12 |
| Stripping length | 6.5 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Connection method | Screw connection |
|---|---|
| Conductor cross-section, rigid min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 2.5 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section flexible max. | 2.5 mm² |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section AWG max. | 12 |
| Stripping length | 6.5 mm |
| Screw thread | M3 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Types of signaling | LED |
|---|---|
| Operating voltage display | Green LED |
| Signalization designation | DC OK, active |
|---|---|
| Status display | "DC OK" LED green |
| Note on status display | UOUT > 3.7 V - LED on |
| Number of phases | 1 |
|---|---|
| Insulation voltage input/output | 4 kV AC (type test); 3.75 kV AC (routine test); 3.75 kV AC (routine test); 4 kV AC (type test) |
| Insulation voltage output / PE | 500 V DC (routine test) |
| Insulation voltage input / PE | 3.5 kV AC (type test); 2 kV AC (routine test) |
| Product type | Power supply |
|---|---|
| Product family | STEP POWER |
| MTBF (IEC 61709, SN 29500) | > 1111000 h (40 °C) |
| Protection class | II (in closed control cabinet) |
|---|---|
| Overvoltage category | III |
| Degree of pollution | 2 |
| Width | 72 mm |
|---|---|
| Height | 90 mm |
| Depth Device depth (DIN rail mounting) | 55 mm (Device depth (DIN rail mounting)) |
| Horizontal pitch | 4 HP |
| Installation distance right/left | 0 mm / 0 mm |
|---|---|
| Installation distance top/bottom | 30 mm / 30 mm |
| Mounting type | DIN rail mounting |
|---|---|
| Assembly note | alignable - 0 mm horizontally, 30 mm vertically |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| With protective coating | no |
| Housing material | Plastic; PC |
|---|---|
| Foot latch material | POM (Polyoxymethylene) |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 55° C derating - 2.5%/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Ambient temperature (start-up type tested) | -40 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6); 15 Hz ... 150 Hz, 2.3g, 90 min. |
| Temp code | T4A (60 °C) |
| Rail applications | EN 50121-4 |
|---|---|
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| Standard - Electrical safety | IEC 62368-1 (SELV) |
| Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
| Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard - Safety of transformers | EN 61558-2-16 |
| CSA | CSA-C22.2 No. 107.1-01 |
|---|---|
| Shipbuilding approval | DNV GL (EMC B) ABS, NK |
| UL approvals | UL/C-UL listed UL 508; UL/C-UL Recognized UL 60950-1; UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location) |
| SIL in accordance with IEC 61508 | 0 |
|---|
Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details
Model numbers in this series (2)
Send us the complete code you need and we will quote it.
2868541STEP-PS/ 1AC/ 5DC/6.5
About the STEP-PS/1AC/5DC/6.5
STEP POWER primary-switched power supply for DIN-rail mounting, slim and compact, for distribution boards and building automation. Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 5 V DC/6.5 A Order no. 2868541.