Phoenix Contact QUINT4-SYS-PS/1AC/24DC/2.5/SC QUINT4-SYS-PS/1AC/24DC/2.5/SC Power Supply

Model number
QUINT4-SYS-PS/1AC/24DC/2.5/SC

Primary-switched power supply, QUINT POWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24 V DC/2.5 A

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Phoenix Contact QUINT4-SYS-PS/1AC/24DC/2.5/SC QUINT4-SYS-PS/1AC/24DC/2.5/SC Power Supply.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Output 24 V DC, 2.5 A
  • Input 100 V AC ... 240 V AC
  • Efficiency typ. 93 % (120 V AC)
  • Width 40 mm
  • Operating temperature -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
  • Degree of protection IP20

Specifications

Input data - AC operation
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range100 V AC ... 240 V AC -15 % ... +10 %
Electric strength, max.300 V AC 30 s
Typical national grid voltage120 V AC; 230 V AC
Voltage type of supply voltageAC
Inrush currenttyp. 10 A (at 25 °C)
Inrush current integral (I2t)typ. 0.1 A2s
Inrush current limitation10 A
Frequency range (fN)50 Hz ... 60 Hz ±10 %; 16.7 Hz (acc. to EN 50163)
Mains buffering timetyp. 31 ms (120 V AC); typ. 31 ms (230 V AC)
Current consumption0.85 A (100 V AC); 0.7 A (120 V AC); 0.39 A (230 V AC); 0.37 A (240 V AC)
Nominal power consumption69 VA
Protective circuitTransient surge protection; Varistor
Typical response time500 ms
Input fuse4 A (slow-blow, internal)
Recommended breaker for input protection6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 0.25 mA (264 V AC, 60 Hz); < 0.22 mA
Input data - DC operation
Input voltage range110 V DC ... 250 V DC -20 % ... +40 %
Voltage type of supply voltageDC
Current consumption0.75 A (110 V DC); 0.33 A (250 V DC)
Output data
Efficiencytyp. 93 % (120 V AC); typ. 94 % (230 V AC)
Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 27 V DC (constant capacity)
Nominal output current (IN)2.5 A
Static Boost (IStat.Boost)3.125 A (≤ 40°C)
Dynamic Boost (IDyn.Boost)4 A (≤ 60 °C (on ≤ 5 s/off ≥ 5 s))
Feedback voltage resistance≤ 32 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC ±2 %
Control deviation< 0.5 % (Static load change 10 % ... 90 %); < 2 % (Dynamic load change 10 % ... 90 %, (10 Hz)); < 0.25 % (change in input voltage ±10 %)
Residual ripple< 40 mVPP (with nominal values)
Short-circuit-proofyes
No-load proofyes
Output power60 W; 75 W; 96 W
Maximum no-load power dissipation< 1 W (120 V AC); < 1 W (230 V AC)
Power loss nominal load max.< 5 W (120 V AC); < 4 W (230 V AC)
Crest factortyp. 1.8 (120 V AC); typ. 1.84 (230 V AC)
Rise time50 ms (UOut = 10 % ... 90 %)
Fuse protection (secondary side)electronic
Output data - Signal (configurable)
Digital0 V DC 24 V DC 30 mA
Default24 V DC 30 mA 24 V DC for UOut > 0.9 x USet
Connection data - Input
Connection methodScrew connection
Conductor cross-section, rigid min.0.14 mm²
Conductor cross-section, rigid max.2.5 mm²
Conductor cross-section flexible min.0.14 mm²
Conductor cross-section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross-section AWG min.26
Conductor cross-section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Connection data - Output
Connection methodScrew connection
Conductor cross-section, rigid min.0.14 mm²
Conductor cross-section, rigid max.2.5 mm²
Conductor cross-section flexible min.0.14 mm²
Conductor cross-section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross-section AWG min.26
Conductor cross-section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Connection data - Signal
Connection methodScrew connection
Conductor cross-section, rigid min.0.14 mm²
Conductor cross-section, rigid max.2.5 mm²
Conductor cross-section flexible min.0.14 mm²
Conductor cross-section flexible max.2.5 mm²
Single conductor/terminal point, stranded, with ferrule, min.0.25 mm²
Single conductor/terminal point, stranded, with ferrule, max.2.5 mm²
Conductor cross-section AWG min.26
Conductor cross-section AWG max.14
Stripping length8 mm
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Signaling
Types of signalingLED
Signaling - Signal output
POut> PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
UOut> 0.9 x USet (LED lights up green); < 0.9 x USet (LED flashes green)
Electrical properties
Number of phases1
Insulation voltage input/output4 kV AC (type test); 3 kV AC (routine test)
Switching frequency90.00 kHz ... 110.00 kHz (Auxiliary converter stage); 50.00 kHz ... 195.00 kHz (Main converter stage); 60.00 kHz ... 360.00 kHz (PFC stage)
Product properties
Product typePower supply
Product familyQUINT POWER
MTBF (IEC 61709, SN 29500)> 2000000 h (25 °C); > 1161000 h (40 °C); > 514000 h (60 °C)
Environmental protection directiveRoHS Directive 2011/65/EU; WEEE; Reach
Product properties - Insulation characteristics
Protection classII
Overvoltage category (EN 61010-1)II (≤ 5000 m)
Overvoltage category (EN 62477-1)III (≤ 2000 m)
Degree of pollution2
Dimensions
Width40 mm
Height99 mm
Depth114 mm
Dimensions - Installation dimensions
Installation distance right/left (active)15 mm / 15 mm (POut ≥50% )
Installation distance right/left (passive)5 mm / 5 mm (POut ≥50% )
Installation distance right/left (active, passive)0 mm / 0 mm (POut ≤50 %)
Installation distance top/bottom (active)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (passive)30 mm / 30 mm (POut ≥50% )
Installation distance top/bottom (active, passive)30 mm / 30 mm (POut ≤50 %)
Mounting
Mounting typeDIN rail mounting
With protective coatingyes
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialPlastic
Type of housingPolycarbonate
Hood versionPolycarbonate
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Temp codeT4 (-25 ... +70 °C; > 60 °C, Derating - 2,5 %/K)
Standards and regulations
Rail applicationsEN 50121-3-2; EN 50121-4; EN 50121-5; IEC 62236-3-2; IEC 62236-4; IEC 62236-5
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard – Safety extra-low voltageIEC 61010-1 (SELV); IEC 61010-2-201 (PELV)
Standard - Safe isolationIEC 61558-2-16; IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1; IEC 61010-2-201 (SELV)
Standard - Safety of transformersEN 61558-2-16
Approvals
UL approvalsUL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Approvals - ATEX
IdentificationUL 21 ATEX 2597 X;  II 3 G Ex ec nC IIC T4 Gc
Approvals - IECEx
IdentificationIECEx ULD 21.0023X; Ex ec nC IIC T4 Gc
Approvals - UKEX
IdentificationUL21UKEX2208X
Approvals - UL
IdentificationUL Listed UL 61010-1; UL Listed UL 61010-2-201; UL 1310 Class 2 Power Units; ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Approvals - SIQ
IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

Specifications are from the manufacturer's published information. Confirm critical values with us or the datasheet before ordering. Brand names, logos and model names are trademarks of their respective owners, used only to identify the product. Details

Model numbers in this series (1)

Send us the complete code you need and we will quote it.

  • 2904614

About the QUINT4-SYS-PS/1AC/24DC/2.5/SC

QUINT POWER power supply for DIN-rail mounting with maximum functionality. Primary-switched power supply, QUINT POWER, screw connection, DIN rail mounting, supply of devices possible via the TBUS DIN rail connector, protective coating, input: single-phase, output: 24 V DC/2.5 A Order no. 2904614.