Phoenix Contact QUINT4-PS/24DC/24DC/5/PT QUINT4-PS/24DC/24DC/5/PT DC/DC Converter

Model number
QUINT4-PS/24DC/24DC/5/PT

Primary-switched DC/DC converter, QUINT POWER DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 24 V DC, output: 24 V DC / 5 A

Price and availability on request

We reply by email or phone, Monday to Saturday, 10:30 am to 6:30 pm.

Several models? Add each to your enquiry list and send them as one enquiry.

Request a quote

Sent with the product details: Phoenix Contact QUINT4-PS/24DC/24DC/5/PT QUINT4-PS/24DC/24DC/5/PT DC/DC Converter.

A phone number or an email address is needed, so we can reply.

We use these details only to reply to your enquiry. See our privacy notice.

Key features

  • Output 24 V DC, 5 A (120 W)
  • Input 24 V DC
  • Efficiency typ. 92.2 % (24 V DC)
  • Width 36 mm
  • Operating temperature -25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
  • Degree of protection IP20

Specifications

Input data
Nominal input voltage range24 V DC
Input voltage range24 V DC -25 % ... +40 %
Wide-range inputno
Electric strength, max.35 V DC (60 s)
Inrush currenttyp. 1 A
Inrush current integral (I2t)< 0.05 A2s
Inrush current limitation1 A
Mains buffering timetyp. 14 ms (24 V DC)
Current consumption6.9 A (24 V DC)
Nominal power consumption130 VA
Typical response time300 ms (from SLEEP MODE)
Switch-on time< 1 s
Input fuse15 A (slow-blow, internal)
Recommended breaker for input protection10 A ... 16 A (Characteristic B, C, D, K or comparable)
Output data
Efficiencytyp. 92.2 % (24 V DC)
Output characteristicU/I Advanced; Smart HICCUP; FUSE MODE
Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
Nominal output current (IN)5 A
Static Boost (IStat.Boost)6.25 A
Dynamic Boost (IDyn.Boost)10 A (5 s)
Selective Fuse Breaking (ISFB)30 A (15 ms)
Magnetic circuit breaker trippingA1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
Short-circuit-proofyes
No-load proofyes
Output power (PN)120 W
Output power (PStat. Boost)150 W
Output power (PDyn. Boost)240 W (5 s)
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 32 V DC
Residual ripple< 10 mVPP
Control deviation static< 1 % (change in load, static 10 % ... 90 %)
Control deviation dynamic< 1 % (change in load, static 10 % ... 90 %)
Control deviation Input voltage change< 1 % (change in load, static 10 % ... 90 %)
Rise time< 100 ms (UOUT (10 % ... 90 %))
Connection in seriesyes
Maximum no-load power dissipation< 2 W
Power loss nominal load max.< 10 W
Power dissipation SLEEP MODE< 1 W
Connection in parallelyes, for redundancy and increased capacity
Fuse protection (secondary side)electronic; thermal-magnetic; thermal
Connection data - Input
Position1.x
Connection data - Conductor connection
Connection methodPush-in connection
rigid0.2 mm² ... 6 mm²; 0.2 mm² ... 1 mm²
flexible0.2 mm² ... 6 mm²; 0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve0.2 mm² ... 4 mm²; 0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve0.2 mm² ... 4 mm²; 0.2 mm² ... 0.75 mm²
rigid (AWG)24 ... 10; 24 ... 16
Stripping length10 mm; 8 mm
Connection data - Output
Position2.x
Connection data - Signal
Position3.x
Signaling - LED signaling
Types of signalingLED; Floating signal contact; Active signal output Out1 (digital, configurable); Active signal output Out2 (analog, configurable); Remote contact; Signal ground SGnd
Signal threshold> 100 % (LED lights up yellow, output power > 120 W); > 75 % (LED lights up green, output power > 90 W); > 50 % (LED lights up green, output power > 60 W); > 0.9 x USet (LED lights up green); < 0.9 x USet (LED flashes green); > 0.8 x UInNom (LED off); < 0.8 x UInNom (LED lights up yellow)
Signaling - Signal input Remote (configurable)
Connection labeling3.3 +
FunctionOutput power ON/OFF (remote)
DefaultOutput power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
Signaling - Signal output Out 1 (configurable)
Connection labeling3.5 +
Digital0 V DC; 24 V DC; 20 mA
DefaultUIN input voltage OK
Signal optionOutput voltage; Output current; Output power; Operating hours; Early warning of high temperatures; OVP voltage limitation active
Signaling - Signal output Out 2 (configurable)
Connection labeling3.6 +
Digital0 V DC; 24 V DC; 20 mA
DefaultOutput power
Signal optionOutput voltage; Output current; Operating hours; Early warning of high temperatures; OVP voltage limitation active; Output voltage; Output current; Output power
Analog4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Signaling - Signal output Relay 13/14 (configurable)
Connection labeling3.1, 3.2
Switch contact (floating)floating
Digital24 V DC; 1 A; 30 V AC; 0.5 A
DefaultOutput voltage
Signal optionOutput current; Output power; Operating hours; Early warning of high temperatures; OVP voltage limitation active; UIN input voltage OK
Signaling - Signal ground SGnd
Connection labeling3.4 +
FunctionSignal ground
Reference potentialfor OUT1, OUT2, REM
Electrical properties
Number of phases1.00
Insulation voltage input/output4 kV DC (type test); 2 kV DC (routine test)
Switching frequency190.00 kHz ... 220.00 kHz (Auxiliary converter stage); 50.00 kHz ... 420.00 kHz (Main converter stage)
Product properties
Product typeDC/DC converters
Product familyQUINT POWER
MTBF (IEC 61709, SN 29500)> 1600000 h (25 °C); > 930000 h (40 °C); > 380000 h (60 °C)
Product properties - Insulation characteristics
Protection classSpecial with SELV input and output
Overvoltage category (EN 61010-1)II (≤ 5000 m)
Overvoltage category (EN 62477-1)III (≤ 5000 m)
Degree of pollution2
Dimensions - Item dimensions
Width36 mm
Height130 mm
Depth125 mm
Dimensions - Item dimensions with alternative mounting
Width122 mm
Height130 mm
Depth39 mm
Dimensions - Installation dimensions
Installation distance right/left (active)15 mm / 15 mm (≤ 70 °C)
Installation distance right/left (passive)0 mm / 0 mm (≤ 70 °C)
Installation distance top/bottom (active)50 mm / 50 mm (≤ 70 °C)
Installation distance top/bottom (passive)50 mm / 50 mm (≤ 70 °C)
Mounting
Mounting typeDIN rail mounting
Assembly notealignable - PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable - PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
With protective coatingno
Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialMetal
Hood versionStainless steel X6Cr17
Side element versionAluminum
Environmental and real-life conditions - Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating - 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Ambient temperature (start-up type tested)-40 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K22 (in accordance with EN 60721-3-3)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)5 Hz ... 100 Hz, 2.3g (in accordance with DNV Class A and C); 5 Hz ... 100 Hz, 4.0g (in accordance with DNV Class B), only with UWA 130 mounting adapter
Temp codeT4 (-25 ... +70 °C; > 60 °C, Derating - 2,5 %/K)
Standards and regulations - Safety for measurement, control, and laboratory equi
Standard designationElectrical safety (of control and regulation devices)
Standards/specificationsIEC 61010-1
Standards and regulations - Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsEN 61010-1 (SELV); IEC 61010-2-201 (PELV)
Standards and regulations - Mains voltage dips
Standard designationMains variation/undervoltage
Standards/specificationsEN 61000-4-29
Standards and regulations - Railway applications
Standard designationRailway applications
Standards/specificationsEN 50121-3-2; IEC 62236-3-2
Approvals - UL
IdentificationUL Listed UL 61010-1; UL Listed UL 61010-2-201; UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Approvals - CSA
IdentificationCAN/CSA-C22.2 No. 61010-1-12; CAN/CSA C22.2 No. 61010-2-201-18
Approvals - SIQ
IdentificationType tested (type approved); CB scheme (IEC 61010-1, IEC 61010-2-201)
Approvals - Shipbuilding
IdentificationDNV; ABS; BV; NK; LR